Tigo EI Automatic Transfer Switch, 200 A with generator support (TSS-200-US-G, 801-200200-0301)

By Tigo EnergySKU 801-200200-0301

No reviews · Write the first

Key specs

Units
SKU
801-200200-0301
Official datasheet
Sources

Tigo prints "200 A ATS MCB w/ generator support TSS-200-US-G 801-200200-0301" in the ordering table.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Ordering Information

Documented

Weight
29.5 kg65 lb converted
Official datasheet
Sources

Printed as "Weight 15.6 kg (34.3 lb.) 29.5 kg (65 lb.)", where 29.5 kg is the 200 A column.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Environmental, 200 A column

Documented

Safety listing
UL 1741, UL 869A, CSA 22.2 No. 107.1, CSA 22.2 No. 0.19
Official datasheet
Sources

Printed as "TSS-200-US/G – UL 1741, UL 869A, CSA 22.2 No. 107.1, CSA 22.2 No. 0.19". These are the maker's statements; no listing record was checked.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Certifications

Documented

Dimensions
61.31 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 550 × H: 455 × D: 245 mmW: 21.7 × H: 17.9 × D: 9.65 in convertedOfficial datasheet
Sources

Printed as "455/550/245 mm (17.9/21.6/9.6 in.)" in the 200 A column of the height/width/depth row.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Environmental, Height/width/depth, 200 A column

Calculated

Mounting
Wall mount
Official datasheet
Sources

Printed as "Installation Wall mount".

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: General

Documented

Current rating
200 A
Official datasheet
Sources

Printed as "200 A ATS MCB w/ generator support" in the ordering table and "Maximum input current 48 A 200 A" in the Grid section, where 200 A is the 200 A column. The maximum continuous grid input current is printed as 160 A.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Ordering Information; Grid, 200 A column

Documented

Enclosure
NEMA 4X (IP65)
Official datasheet
Sources

Printed as "Ingress protection NEMA 4X (IP65)".

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: General

Documented

Operation
Automatic
Official datasheet
Sources

Printed as "EI Automatic Transfer Switch (ATS)"; a manual bypass switch is printed as "Yes" for the 200 A models.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Title

Documented

Transfer time
500 ms
Official datasheet
Sources

Printed as "Grid to inverter switchover time <2 sec. <500 msec.", where <500 msec. is the 200 A column; the value is an upper bound (less than 500 ms). The Generator Support table prints "Off-grid to generator switchover <500 msec." and "Generator to off-grid switchover <600 msec.".

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Grid, 200 A column

Documented

All specs9
Weight
29.5 kg65 lb converted
Official datasheet
Sources

Printed as "Weight 15.6 kg (34.3 lb.) 29.5 kg (65 lb.)", where 29.5 kg is the 200 A column.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Environmental, 200 A column

Documented

Safety listing
UL 1741, UL 869A, CSA 22.2 No. 107.1, CSA 22.2 No. 0.19
Official datasheet
Sources

Printed as "TSS-200-US/G – UL 1741, UL 869A, CSA 22.2 No. 107.1, CSA 22.2 No. 0.19". These are the maker's statements; no listing record was checked.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Certifications

Documented

Dimensions
245 D × 550 W × 455 H mm9.65 D × 21.7 W × 17.9 H in converted
Official datasheet
Sources

Printed as "455/550/245 mm (17.9/21.6/9.6 in.)" in the 200 A column of the height/width/depth row.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Environmental, Height/width/depth, 200 A column

Documented

Mounting
Wall mount
Official datasheet
Sources

Printed as "Installation Wall mount".

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: General

Documented

Current rating
200 A
Official datasheet
Sources

Printed as "200 A ATS MCB w/ generator support" in the ordering table and "Maximum input current 48 A 200 A" in the Grid section, where 200 A is the 200 A column. The maximum continuous grid input current is printed as 160 A.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Ordering Information; Grid, 200 A column

Documented

Enclosure
NEMA 4X (IP65)
Official datasheet
Sources

Printed as "Ingress protection NEMA 4X (IP65)".

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: General

Documented

Operation
Automatic
Official datasheet
Sources

Printed as "EI Automatic Transfer Switch (ATS)"; a manual bypass switch is printed as "Yes" for the 200 A models.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Title

Documented

Transfer time
500 ms
Official datasheet
Sources

Printed as "Grid to inverter switchover time <2 sec. <500 msec.", where <500 msec. is the 200 A column; the value is an upper bound (less than 500 ms). The Generator Support table prints "Off-grid to generator switchover <500 msec." and "Generator to off-grid switchover <600 msec.".

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Grid, 200 A column

Documented

Voltage rating
240 V
Official datasheet
Sources

Printed as "Nominal voltage 240 V" for the grid, with an operating voltage range (L-L) of 180 to 270 V; the output is printed as 120/240 VAC.

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: Grid

Documented

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo EnergyOfficialTigo EnergyOfficial datasheetAugust 14, 2024
    Source details
    Revision
    Rev. 3.1
    Revision date
    August 14, 2024

    Archived copy captured on 2026-10-02.

    Location: Specifications and Ordering Information

    Retrieved

    Tigo Energy's EI US ATS datasheet (Rev. 3.1, dated 2024-08-14). Specifications are printed in a 50 A column and a 200 A column; the 200 A column covers both TSS-200-US and TSS-200-US-G, and a separate Generator Support table applies to TSS-200-US-G only.

    Archived copies

    Archived copy of a document published by Tigo Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Rev. 3.1 · 0.49 MB

    Archived copy, unaltered, kept as a record of what Tigo Energy published. Original address: https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/66bd2d3ed2517e70e6d0c01f_002-00087-00%203.1%20Datasheet%20EI%20US%20ATS%2020240814%20-%20EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2024-08-14

    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e7f41648e50869cf52ea3a48d65ded0ecbcad94fff8a185d2af960e4aa5aedcc

    Open
  • WEB
    EI Automatic Transfer Switch product page, Tigo EnergyOfficialTigo EnergyOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-02.

    Location: Product page

    Retrieved

    Tigo Energy's ATS product page; the figures are taken from the datasheet it links.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy

Archived copy of a document published by Tigo Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Rev. 3.1 · 0.49 MB

Archived copy, unaltered, kept as a record of what Tigo Energy published. Original address: https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/66bd2d3ed2517e70e6d0c01f_002-00087-00%203.1%20Datasheet%20EI%20US%20ATS%2020240814%20-%20EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2024-08-14

Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e7f41648e50869cf52ea3a48d65ded0ecbcad94fff8a185d2af960e4aa5aedcc

Submit a document

Warranty

Product warranty
11 years
Official datasheet
Sources

Printed as "Warranty 11 years".

Official datasheet: EI Automatic Transfer Switch (ATS) datasheet, 002-00087-00 Rev. 3.1, Tigo Energy Rev Rev. 3.1 · August 14, 2024 · Checked · Earlier document

Location: General

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
TSS-200-US-G

Manufacturer SKU 801-200200-0301 · US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice