SolarEdge S440 Power Optimizer

By SolarEdgeSKU not documented

No reviews · Write the first

Key specs

Units
Weight
0.72 kg1.6 lb converted
Converted: 720 g / 1000 g/kg
Distributor datasheet
Sources

Converted: 720 g / 1000 g/kg

Printed as "720" gr; the gram figure is converted to kilograms.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INSTALLATION SPECIFICATIONS, Weight

Converted

Safety listing
IEC62109-1 (class II safety), UL1741; EMC: FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Distributor datasheet
Sources

Printed as "EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3" and "Safety IEC62109-1 (class II safety), UL1741". Manufacturer claims; no certificate was read.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, STANDARD COMPLIANCE

Documented

Device type
Power optimizer (module-level MPPT, monitoring and rapid shutdown)
Distributor datasheet
Sources

The data sheet is titled "Power Optimizer For North America" and describes "PV power optimization at the module level" and "Module-level voltage shutdown for installer and firefighter safety".

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, title

Documented

Dimensions
0.6 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 129 × H: 30 × L: 155 mmW: 5.08 × H: 1.2 × L: 6.1 in convertedDistributor datasheet
Sources

Printed as "129 x 155 x 30" mm (W x L x H); the printed millimeter figures are recorded.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

Calculated

Efficiency
99.5 %
Distributor datasheet
Sources

Printed as "99.5" %, one cell shared by all 3 models.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, Maximum Efficiency

Documented

MPPT voltage range
8 to 60 V
Distributor datasheet
Sources

Printed as "8 – 60" Vdc.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, MPPT Operating Range

Documented

Enclosure
IP68 / NEMA6P
Distributor datasheet
Sources

Printed as "IP68 / NEMA6P".

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INSTALLATION SPECIFICATIONS, Protection Rating

Documented

Maximum input power
440 W
Distributor datasheet
Sources

Rated Input DC Power printed as "440" W; footnote (1): the rated power of the module at STC will not exceed it, with modules of up to +5% power tolerance allowed.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, Rated Input DC Power

Documented

All specs14
Weight
0.72 kg1.6 lb converted
Converted: 720 g / 1000 g/kg
Distributor datasheet
Sources

Converted: 720 g / 1000 g/kg

Printed as "720" gr; the gram figure is converted to kilograms.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INSTALLATION SPECIFICATIONS, Weight

Converted

Safety listing
IEC62109-1 (class II safety), UL1741; EMC: FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Distributor datasheet
Sources

Printed as "EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3" and "Safety IEC62109-1 (class II safety), UL1741". Manufacturer claims; no certificate was read.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, STANDARD COMPLIANCE

Documented

Device type
Power optimizer (module-level MPPT, monitoring and rapid shutdown)
Distributor datasheet
Sources

The data sheet is titled "Power Optimizer For North America" and describes "PV power optimization at the module level" and "Module-level voltage shutdown for installer and firefighter safety".

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, title

Documented

Dimensions
129 W × 30 H × 155 L mm5.08 W × 1.2 H × 6.1 L in converted
Distributor datasheet
Sources

Printed as "129 x 155 x 30" mm (W x L x H); the printed millimeter figures are recorded.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

Documented

Efficiency
99.5 %
Distributor datasheet
Sources

Printed as "99.5" %, one cell shared by all 3 models.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, Maximum Efficiency

Documented

MPPT voltage range
8 to 60 V
Distributor datasheet
Sources

Printed as "8 – 60" Vdc.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, MPPT Operating Range

Documented

Enclosure
IP68 / NEMA6P
Distributor datasheet
Sources

Printed as "IP68 / NEMA6P".

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INSTALLATION SPECIFICATIONS, Protection Rating

Documented

Maximum input power
440 W
Distributor datasheet
Sources

Rated Input DC Power printed as "440" W; footnote (1): the rated power of the module at STC will not exceed it, with modules of up to +5% power tolerance allowed.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, Rated Input DC Power

Documented

Maximum input voltage
60 V
Distributor datasheet
Sources

Printed as "60" Vdc.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, Absolute Maximum Input Voltage (Voc)

Documented

Maximum output current
15 A
Distributor datasheet
Sources

Printed as "15" Adc, one cell shared by all 3 models; the maximum output voltage is printed as "60" Vdc for this model, and the safety output voltage in standby as "1 ± 0.1" Vdc.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, OUTPUT DURING OPERATION, Maximum Output Current

Documented

PV short-circuit current limit
14.5 A
Distributor datasheet
Sources

Printed as "14.5" Adc, the limit for the connected module.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, Maximum Short Circuit Current (Isc) of Connected PV Module

Documented

Operating temperature
-40 to 85 °C-40 to 185 °F converted
Distributor datasheet
Sources

Printed as "-40 to +85" ˚C; footnote (3): power de-rating above +85°C for S440 and above +75°C for S500B.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INSTALLATION SPECIFICATIONS, Operating Temperature Range

Documented

Weighted efficiency
98.6 %
Distributor datasheet
Sources

Printed as "98.6" %, one cell shared by all 3 models.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, INPUT, Weighted Efficiency

Documented

Rapid shutdown compliance
Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020
Distributor datasheet
Sources

Printed as "Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020". Manufacturer claim.

Distributor datasheet: "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023) Rev DS-000018-NA · April 3, 2023 · Checked · Earlier document

Location: SolarEdge Power Optimizer data sheet for North America DS-000018-NA (Date: April 3, 2023), PDF page 2, S440 column, STANDARD COMPLIANCE

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • WEB
    "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023)SolarEdgeDistributor datasheetApril 3, 2023
    Source details
    Revision
    DS-000018-NA
    Revision date
    April 3, 2023

    Archived copy obtained from 7534425.app.netsuite.com (the BayWa r.e. US store's file host, a distributor), captured 2026-10-13 at 07:04:01 UTC by Alternative Research. The copy read hashes to the SHA-256 Alternative Research recorded for it.

    Retrieved

    SolarEdge's own data sheet "Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023). One column per model, with some cells spanning columns. This copy was obtained from 7534425.app.netsuite.com (the BayWa r.e. US store's file host, a distributor), captured 2026-10-13 at 07:04:01 UTC by Alternative Research (www.solaredge.com blocks our fetcher). Read in full; table columns were checked on the rendered pages. Manufacturer claims, not an independent test.

    Archived copies

    Archived copy of a document published by SolarEdge. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup DS-000018-NA · 0.19 MB

    Archived copy, unaltered, kept as a record of what SolarEdge published. Original address: https://7534425.app.netsuite.com/core/media/media.nl?_xt=.pdf&c=7534425&h=zzCkgNMvKwQO8Ku_wcwlrqGGj8VGpPhKDaOQv2lS18g8iNvd&id=4153368. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2023-04-03

    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: eb04b0791333bcf23d015f447ff3683f96cb14e7843856541cd0fdd350da1729

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

"Power Optimizer For North America S440 / S500B / S650B" (DS-000018-NA, Date: April 3, 2023)

Archived copy of a document published by SolarEdge. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup DS-000018-NA · 0.19 MB

Archived copy, unaltered, kept as a record of what SolarEdge published. Original address: https://7534425.app.netsuite.com/core/media/media.nl?_xt=.pdf&c=7534425&h=zzCkgNMvKwQO8Ku_wcwlrqGGj8VGpPhKDaOQv2lS18g8iNvd&id=4153368. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2023-04-03

Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: eb04b0791333bcf23d015f447ff3683f96cb14e7843856541cd0fdd350da1729

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
S440

US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.