Key specs

Units
Weight
1.11 kg2.44 lb converted
Converted: 1106 g / 1000 g/kg
Source datasheet
Sources

Converted: 1106 g / 1000 g/kg

Printed as "1106 / 2.4" gr / lb; the gram figure is converted to kilograms.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INSTALLATION SPECIFICATIONS, Weight

Converted

Safety listing
IEC62109-1 (class II safety), UL1741, CSA C22.2#107.1; EMC: FCC Part15, IEC 61000-6-2, IEC 61000-6-3
Source datasheet
Sources

Printed as "EMC FCC Part15, IEC 61000-6-2, and IEC 61000-6-3" and "Safety IEC62109-1 (class II safety), UL1741, CSA C22.2#107.1". Manufacturer claims; no certificate was read.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, STANDARD COMPLIANCE, Safety and EMC

Documented

Device type
Power optimizer, ground mount (module-level MPPT, monitoring and rapid shutdown)
Source datasheet
Sources

The data sheet is titled "Power Optimizer Ground Mount for North America S1200" and describes module-level MPPT, module-level monitoring and automatic reduction of DC voltage to touch-safe levels (SafeDC) upon grid or inverter shutdown.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM, page titles and PDF page 1

Documented

Dimensions
1.18 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 129 × H: 59 × L: 155 mmW: 5.08 × H: 2.3 × L: 6.1 in convertedSource datasheet
Sources

Printed as "129 x 155 x 59 / 5.08 x 6.10 x 2.32" mm / in (W x L x H); the printed millimeter figures are recorded.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

Calculated

Efficiency
99.5 %
Source datasheet
Sources

Printed as "Maximum Efficiency 99.5 %".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, Maximum Efficiency

Documented

MPPT voltage range
12.5 to 105 V
Source datasheet
Sources

Printed as "MPPT Operating Range 12.5-105 Vdc".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, MPPT Operating Range

Documented

Enclosure
IP68 / NEMA6P
Source datasheet
Sources

Printed as "IP68 / NEMA6P".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INSTALLATION SPECIFICATIONS, Protection Rating

Documented

Maximum input power
1,200 W
Source datasheet
Sources

Rated Input DC Power printed as "1200" W; footnote (1): the rated power of the module at STC will not exceed the power optimizer Rated Input DC Power, and modules with up to +5% power tolerance are allowed.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, Rated Input DC Power

Documented

All specs14
Weight
1.11 kg2.44 lb converted
Converted: 1106 g / 1000 g/kg
Source datasheet
Sources

Converted: 1106 g / 1000 g/kg

Printed as "1106 / 2.4" gr / lb; the gram figure is converted to kilograms.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INSTALLATION SPECIFICATIONS, Weight

Converted

Safety listing
IEC62109-1 (class II safety), UL1741, CSA C22.2#107.1; EMC: FCC Part15, IEC 61000-6-2, IEC 61000-6-3
Source datasheet
Sources

Printed as "EMC FCC Part15, IEC 61000-6-2, and IEC 61000-6-3" and "Safety IEC62109-1 (class II safety), UL1741, CSA C22.2#107.1". Manufacturer claims; no certificate was read.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, STANDARD COMPLIANCE, Safety and EMC

Documented

Device type
Power optimizer, ground mount (module-level MPPT, monitoring and rapid shutdown)
Source datasheet
Sources

The data sheet is titled "Power Optimizer Ground Mount for North America S1200" and describes module-level MPPT, module-level monitoring and automatic reduction of DC voltage to touch-safe levels (SafeDC) upon grid or inverter shutdown.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM, page titles and PDF page 1

Documented

Dimensions
129 W × 59 H × 155 L mm5.08 W × 2.3 H × 6.1 L in converted
Source datasheet
Sources

Printed as "129 x 155 x 59 / 5.08 x 6.10 x 2.32" mm / in (W x L x H); the printed millimeter figures are recorded.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

Documented

Efficiency
99.5 %
Source datasheet
Sources

Printed as "Maximum Efficiency 99.5 %".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, Maximum Efficiency

Documented

MPPT voltage range
12.5 to 105 V
Source datasheet
Sources

Printed as "MPPT Operating Range 12.5-105 Vdc".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, MPPT Operating Range

Documented

Enclosure
IP68 / NEMA6P
Source datasheet
Sources

Printed as "IP68 / NEMA6P".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INSTALLATION SPECIFICATIONS, Protection Rating

Documented

Maximum input power
1,200 W
Source datasheet
Sources

Rated Input DC Power printed as "1200" W; footnote (1): the rated power of the module at STC will not exceed the power optimizer Rated Input DC Power, and modules with up to +5% power tolerance are allowed.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, Rated Input DC Power

Documented

Maximum input voltage
125 V
Source datasheet
Sources

Printed as "Absolute Maximum Input Voltage (Voc) 125 Vdc".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, Absolute Maximum Input Voltage (Voc)

Documented

Maximum output current
18 A
Source datasheet
Sources

Printed as "Maximum Output Current 18 Adc"; the maximum output voltage is printed as 80 Vdc, and the safety output voltage per power optimizer in standby as 1 Vdc.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, OUTPUT DURING OPERATION, Maximum Output Current

Documented

PV short-circuit current limit
15 A
Source datasheet
Sources

Printed as "Maximum Short Circuit Current (Isc) of Connected PV Module 15 Adc", the limit for the connected module.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, Maximum Short Circuit Current (Isc) of Connected PV Module

Documented

Operating temperature
-40 to 85 °C-40 to 185 °F converted
Source datasheet
Sources

Printed as "-40 to +85 / -40 to +185" ˚C / ˚F; footnote (4): for ambient temperatures above +65°C / +149°F power de-rating is applied.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INSTALLATION SPECIFICATIONS, Operating Temperature Range

Documented

Weighted efficiency
98.8 %
Source datasheet
Sources

Printed as "Weighted Efficiency 98.8 %".

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, INPUT, Weighted Efficiency

Documented

Rapid shutdown compliance
Photovoltaic Rapid Shutdown System compliant with NEC 2014, 2017, 2020
Source datasheet
Sources

Printed as "Photovoltaic Rapid Shutdown System Compliant with NEC 2014, 2017, 2020". Manufacturer claim.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM (Date: February 6, 2023), PDF page 2, STANDARD COMPLIANCE, Photovoltaic Rapid Shutdown System

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • WEB
    SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023)SolarEdgeSource datasheetFebruary 6, 2023
    Source details
    Revision
    DS-000132-NAM
    Revision date
    February 6, 2023

    Archived copy of SolarEdge's document, obtained from 7534425.app.netsuite.com (copy of SolarEdge's document; www.solaredge.com blocks our fetcher), captured 2026-10-13 at 02:03:57 UTC by Alternative Research. The copy read hashes to the SHA-256 Alternative Research recorded for it.

    Retrieved

    SolarEdge's own data sheet titled "Power Optimizer Ground Mount for North America S1200", printed "Date: February 6, 2023 DS-000132-NAM". Two pages; its table (PDF page 2) has one column, for the S1200. This copy was obtained from 7534425.app.netsuite.com (copy of SolarEdge's document; www.solaredge.com blocks our fetcher), captured 2026-10-13 at 02:03:57 UTC by Alternative Research. Read in full; each model's column was checked on the rendered pages. Manufacturer claims, not an independent test.

    Archived copies

    Archived copy of a document published by SolarEdge. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup DS-000132-NAM · 0.19 MB

    Archived copy, unaltered, kept as a record of what SolarEdge published. Original address: https://7534425.app.netsuite.com/core/media/media.nl?_xt=.pdf&c=7534425&h=qCVHU1OP7qmd5ImnXESoW285jZ9fxYo87ugWigKEpbLKRWYM&id=4153060. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2023-02-06

    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d3b660f634a8bc72d9473601ff0281290267449ff61bc6dd8be5363cdae3052f

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023)

Archived copy of a document published by SolarEdge. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup DS-000132-NAM · 0.19 MB

Archived copy, unaltered, kept as a record of what SolarEdge published. Original address: https://7534425.app.netsuite.com/core/media/media.nl?_xt=.pdf&c=7534425&h=qCVHU1OP7qmd5ImnXESoW285jZ9fxYo87ugWigKEpbLKRWYM&id=4153060. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2023-02-06

Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d3b660f634a8bc72d9473601ff0281290267449ff61bc6dd8be5363cdae3052f

Submit a document

Warranty

Product warranty
25 years
Source datasheet
Sources

Page 1 prints "POWER OPTIMIZER 25 YEAR WARRANTY". The full warranty terms were not read.

Source datasheet: SolarEdge Power Optimizer Ground Mount for North America, S1200 (DS-000132-NAM, February 6, 2023) Rev DS-000132-NAM · February 6, 2023 · Checked · Earlier document

Location: SolarEdge's S1200 data sheet DS-000132-NAM, PDF page 1

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
S1200

US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.