Charged Reviews
Quick reference
Sol-Ark External Revenue Grade Meter (RGM) Kit, 900-00080
Model: 900-00080 · SKU: 900-00080
Prepared Nov 12, 2026
Common specifications
| Device type | External revenue grade meter kit for Sol-Ark residential hybrid invertersSource [1] |
|---|---|
| Max switched load (A) | Not documented |
| Max switched load (W) | Not documented |
| Measurement channels | Not documented |
| Current sensors | 200 A split-core current transformers, 0.33333 VAC at rated currentSource [1] |
| Current rating | Not documented |
| Voltage range | Not documented |
| Accuracy | Not documented |
| Communications | RS-485 Modbus RTUSource [1] |
| Display | Not documented |
| Power input | 6 to 24 VDC or 12 to 24 VAC; 1.0 W maximumSource [1] |
| Mounting | Not documented |
| Safety listing | UL Listed U.S./Canada, file E312220; UL/IEC 61010-1; CAN/CSA-C22.2 No. 61010-1-12Source [1] |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.29 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Communications | RS-485 Modbus RTUDocumented claim ConditionsThe communication rows. Location: PDF page 2, page 2, Measurement and Modbus Communication The communication rows. Location: PDF page 2, page 2, Measurement and Modbus Communication |
|---|---|
| Compatibility | Sol-Ark 12K-2P-N, 12K-2P-LL, 15K-2P-LV, 18K-2P-LV (inverter firmware update required)Documented claim ConditionsThe compatibility line and its note. Location: PDF page 1, page 1 The compatibility line and its note. Location: PDF page 1, page 1 |
| Current sensors | 200 A split-core current transformers, 0.33333 VAC at rated currentDocumented claim ConditionsThe kit CT rating and nominal CT input rows. Location: PDF page 2, page 2, Current Transformer Inputs The kit CT rating and nominal CT input rows. Location: PDF page 2, page 2, Current Transformer Inputs |
| Device type | External revenue grade meter kit for Sol-Ark residential hybrid invertersDocumented claim ConditionsThe data sheet heading. Location: PDF page 1, page 1, heading The data sheet heading. Location: PDF page 1, page 1, heading |
| Dimensions | 93.4 W × 29.1 H × 106.4 L mm3.68 W × 1.15 H × 4.19 L in convertedDocumented claim ConditionsPrinted as 106.4 x 93.4 x 29.1 mm without axis labels. Location: PDF page 2, page 2, Regulatory and Physical Specifications Printed as 106.4 x 93.4 x 29.1 mm without axis labels. Location: PDF page 2, page 2, Regulatory and Physical Specifications |
| Included equipment | Meter; 2 x 200 A current transformersDocumented claim ConditionsThe kit contents line. Location: PDF page 1, page 1 The kit contents line. Location: PDF page 1, page 1 |
| Power input | 6 to 24 VDC or 12 to 24 VAC; 1.0 W maximumDocumented claim ConditionsThe meter power supply row. Location: PDF page 2, page 2, Electrical and Current Transformer Inputs The meter power supply row. Location: PDF page 2, page 2, Electrical and Current Transformer Inputs |
| Safety listing | UL Listed U.S./Canada, file E312220; UL/IEC 61010-1; CAN/CSA-C22.2 No. 61010-1-12Documented claim ConditionsThe safety row. Manufacturer claim, no issuer directory was checked. Location: PDF page 2, page 2, Regulatory and Physical Specifications The safety row. Manufacturer claim, no issuer directory was checked. Location: PDF page 2, page 2, Regulatory and Physical Specifications |
| Weight | 0.13 kg0.3 lb convertedCalculated134 g / 1000 g/kg ConditionsPrinted as 134 g (4.7 oz). Location: PDF page 2, page 2, Regulatory and Physical Specifications Printed as 134 g (4.7 oz). Location: PDF page 2, page 2, Regulatory and Physical Specifications |
Warranty
Certificate records
No records documented.
Sources and revisions
- Sol-Ark datasheetOfficial datasheet · Checked https://sol-ark.com/wp-content/uploads/2026/08/Sol-Ark_External_RGM_Datasheet_Rev1_21Aug2026.pdf
- 12K-2P-LL Datasheet V4.0 (EN)Official datasheet · Checked https://sol-ark.com/wp-content/uploads/2026/09/12K-LL_Datasheet_PS-00045_Rev_4_9Sept2026.pdf
- 15K-2P-LV Datasheet V8.0 (EN)Official datasheet · Checked https://sol-ark.com/wp-content/uploads/2026/09/15KDatasheet_PS-00001_Rev_8_10Sept2026.pdf
- 18K-2P-LV Datasheet V8.0 (EN)Official datasheet · Checked https://sol-ark.com/wp-content/uploads/2026/09/18KDatasheet_PS-00036_Rev_8_9Sept2026.pdf