Sol-Ark External Revenue Grade Meter (RGM) Kit, 900-00080

By Sol-ArkSKU 900-00080

No reviews · Write the first

Key specs

Units
SKU
900-00080
Official datasheet
Sources

Sol-Ark's SKU, printed in the heading of the kit's own data sheet.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 1, page 1, heading

Documented

Weight
0.13 kg0.3 lb converted
Converted: 134 g / 1000 g/kg
Official datasheet
Sources

Converted: 134 g / 1000 g/kg

Printed as 134 g (4.7 oz).

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Regulatory and Physical Specifications

Converted

Safety listing
UL Listed U.S./Canada, file E312220; UL/IEC 61010-1; CAN/CSA-C22.2 No. 61010-1-12
Official datasheet
Sources

The safety row. Manufacturer claim, no issuer directory was checked.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Regulatory and Physical Specifications

Documented

Device type
External revenue grade meter kit for Sol-Ark residential hybrid inverters
Official datasheet
Sources

The data sheet heading.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 1, page 1, heading

Documented

Power input
6 to 24 VDC or 12 to 24 VAC; 1.0 W maximum
Official datasheet
Sources

The meter power supply row.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Electrical and Current Transformer Inputs

Documented

Compatibility
Sol-Ark 12K-2P-N, 12K-2P-LL, 15K-2P-LV, 18K-2P-LV (inverter firmware update required)
Official datasheet
Sources

The compatibility line and its note.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 1, page 1

Documented

Dimensions
0.29 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 93.4 × H: 29.1 × L: 106.4 mmW: 3.68 × H: 1.15 × L: 4.19 in convertedOfficial datasheet
Sources

Printed as 106.4 x 93.4 x 29.1 mm without axis labels.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Regulatory and Physical Specifications

Calculated

Communications
RS-485 Modbus RTU
Official datasheet
Sources

The communication rows.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Measurement and Modbus Communication

Documented

Included equipment
Meter; 2 x 200 A current transformers
Official datasheet
Sources

The kit contents line.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 1, page 1

Documented

All specs9
Weight
0.13 kg0.3 lb converted
Converted: 134 g / 1000 g/kg
Official datasheet
Sources

Converted: 134 g / 1000 g/kg

Printed as 134 g (4.7 oz).

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Regulatory and Physical Specifications

Converted

Safety listing
UL Listed U.S./Canada, file E312220; UL/IEC 61010-1; CAN/CSA-C22.2 No. 61010-1-12
Official datasheet
Sources

The safety row. Manufacturer claim, no issuer directory was checked.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Regulatory and Physical Specifications

Documented

Device type
External revenue grade meter kit for Sol-Ark residential hybrid inverters
Official datasheet
Sources

The data sheet heading.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 1, page 1, heading

Documented

Power input
6 to 24 VDC or 12 to 24 VAC; 1.0 W maximum
Official datasheet
Sources

The meter power supply row.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Electrical and Current Transformer Inputs

Documented

Compatibility
Sol-Ark 12K-2P-N, 12K-2P-LL, 15K-2P-LV, 18K-2P-LV (inverter firmware update required)
Official datasheet
Sources

The compatibility line and its note.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 1, page 1

Documented

Dimensions
93.4 W × 29.1 H × 106.4 L mm3.68 W × 1.15 H × 4.19 L in converted
Official datasheet
Sources

Printed as 106.4 x 93.4 x 29.1 mm without axis labels.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Regulatory and Physical Specifications

Documented

Communications
RS-485 Modbus RTU
Official datasheet
Sources

The communication rows.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Measurement and Modbus Communication

Documented

Included equipment
Meter; 2 x 200 A current transformers
Official datasheet
Sources

The kit contents line.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 1, page 1

Documented

Current sensors
200 A split-core current transformers, 0.33333 VAC at rated current
Official datasheet
Sources

The kit CT rating and nominal CT input rows.

Official datasheet: Sol-Ark datasheet Checked · Earlier document

Location: PDF page 2, page 2, Current Transformer Inputs

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    12K-2P-LL Datasheet V4.0 (EN)OfficialSol-ArkOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Sol-Ark publishes this datasheet for 12K-2P-LL and names no other model in this catalog on it. Read from https://sol-ark.com/residential-energy-solutions/limitless-12k-2p-ll-hybrid-inverter/ on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.

    Location: Document title as published

    Retrieved

    Sol-Ark publishes this datasheet for 12K-2P-LL and names no other model in this catalog on it. Read from https://sol-ark.com/residential-energy-solutions/limitless-12k-2p-ll-hybrid-inverter/ on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.

    SHA-256: af6e9180fe5e32702c89d79218a3432c43d1dbf39aaed15e3edba313e7cc4865

    Archived copies

    Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.51 MB

    Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/09/12K-LL_Datasheet_PS-00045_Rev_4_9Sept2026.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    3

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: af6e9180fe5e32702c89d79218a3432c43d1dbf39aaed15e3edba313e7cc4865

    Open

Archive and older revisions

Archive and older revisions3

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • PDF
    15K-2P-LV Datasheet V8.0 (EN)OfficialSol-ArkOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Sol-Ark publishes this datasheet for 15K-2P-LV and names no other model in this catalog on it. Read from https://sol-ark.com/residential-energy-solutions/whole-home-15k-2p-hybrid-inverter/ on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.

    Location: Document title as published

    Retrieved

    Sol-Ark publishes this datasheet for 15K-2P-LV and names no other model in this catalog on it. Read from https://sol-ark.com/residential-energy-solutions/whole-home-15k-2p-hybrid-inverter/ on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.

    SHA-256: 910e12b360f4ed033b86b2cf6f2f76f8335f3895bec9d45742dbffe9230ff0e5

    Archived copies

    Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.47 MB

    Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/09/15KDatasheet_PS-00001_Rev_8_10Sept2026.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    3

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 910e12b360f4ed033b86b2cf6f2f76f8335f3895bec9d45742dbffe9230ff0e5

    Open
  • PDF
    18K-2P-LV Datasheet V8.0 (EN)OfficialSol-ArkOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Sol-Ark publishes this datasheet for 18K-2P-LV and names no other model in this catalog on it. Read from https://sol-ark.com/residential-energy-solutions/premium-18k-2p-hybrid-inverter/ on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.

    Location: Document title as published

    Retrieved

    Sol-Ark publishes this datasheet for 18K-2P-LV and names no other model in this catalog on it. Read from https://sol-ark.com/residential-energy-solutions/premium-18k-2p-hybrid-inverter/ on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.

    SHA-256: 03c5a150b9214a7164a6d8d5773b3a8690471db78e4c6d2aeec1088fc38a28d8

    Archived copies

    Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.47 MB

    Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/09/18KDatasheet_PS-00036_Rev_8_9Sept2026.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    3

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 03c5a150b9214a7164a6d8d5773b3a8690471db78e4c6d2aeec1088fc38a28d8

    Open
  • PDF
    Sol-Ark datasheetOfficialSol-ArkOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 1

    Retrieved

    SHA-256: c67658f10e7761a55a57e22b0570c5ee00b5750b80262b6e3909f59a377ef13e

    Archived copies

    Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.15 MB

    Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/08/Sol-Ark_External_RGM_Datasheet_Rev1_21Aug2026.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: c67658f10e7761a55a57e22b0570c5ee00b5750b80262b6e3909f59a377ef13e

    Open

Archived documents

Sol-Ark datasheet

Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.15 MB

Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/08/Sol-Ark_External_RGM_Datasheet_Rev1_21Aug2026.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: c67658f10e7761a55a57e22b0570c5ee00b5750b80262b6e3909f59a377ef13e

12K-2P-LL Datasheet V4.0 (EN)

Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.51 MB

Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/09/12K-LL_Datasheet_PS-00045_Rev_4_9Sept2026.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
3

Embedded dates are file metadata, not independent proof of publication.

SHA-256: af6e9180fe5e32702c89d79218a3432c43d1dbf39aaed15e3edba313e7cc4865

15K-2P-LV Datasheet V8.0 (EN)

Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.47 MB

Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/09/15KDatasheet_PS-00001_Rev_8_10Sept2026.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
3

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 910e12b360f4ed033b86b2cf6f2f76f8335f3895bec9d45742dbffe9230ff0e5

18K-2P-LV Datasheet V8.0 (EN)

Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.47 MB

Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2026/09/18KDatasheet_PS-00036_Rev_8_9Sept2026.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
3

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 03c5a150b9214a7164a6d8d5773b3a8690471db78e4c6d2aeec1088fc38a28d8

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
900-00080
Published model / SKU
810-00040

Printed as "External RGM Kit (810-00040)" in the optional accessories rows of Sol-Ark's 12K-2P-LL, 15K and 18K data sheets. It differs from the SKU 900-00080 printed in the kit's own data sheet; both are recorded as printed.

Official datasheet: 12K-2P-LL Datasheet V4.0 (EN) Checked · Earlier documentOfficial datasheet: 15K-2P-LV Datasheet V8.0 (EN) Checked · Earlier documentOfficial datasheet: 18K-2P-LV Datasheet V8.0 (EN) Checked · Earlier document

Manufacturer SKU 900-00080

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.