Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S)

By RenogySKU RBC40D1S-US

No reviews · Write the first

Key specs

Units
SKU
RBC40D1S-US
Official store listing
Sources

Printed as "sku":"RBC40D1S-US" for "40A DC-DC Battery Charger with MPPT" in Renogy's US store product data, captured October 21, 2026.

Official store listing: Renogy store Checked · Earlier document

Location: Store product data, variants, "sku" field

Documented

Power
616 W
Official instruction manual
Sources

Printed as "Nominal Output Power 616W"; the store page prints "Output Power 616W".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Weight
1.2 kg2.6 lb converted
Official instruction manual
Sources

Printed as "Weight 1.2 kg /2.65 lb".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Charger input
DC and solar (MPPT)
Official instruction manual
Sources

Printed as "Auxiliary Battery Charging Mode MPPT", with "Start Battery Input Specifications" and "Solar Panel Input Specifications" sections; single-model manual (RBC40D1S-G1).

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: PDF page 30, Specifications (General)

Documented

Dimensions
1.39 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 149 × H: 48 × L: 195 mmW: 5.87 × H: 1.9 × L: 7.68 in convertedOfficial instruction manual
Sources

Printed as "Dimensions (LxWxH) 195 x 149 x 48 mm / 7.68 x 5.87 x 1.89 inch", read as length, width and height.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Calculated

Solar input limit
670 W
Official instruction manual
Sources

Printed as "Maximum Input Power 670W" under "Solar Panel Input Specifications" (the start-battery section prints the same line); PDF page 13 also says the array must not exceed 670W.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: PDF page 30, Specifications (Solar Panel Input Specifications)

Documented

Input voltage
Starter battery 7-16 V DC; solar 13-30 V DC
Official instruction manual
Sources

Printed as "Voltage Range 7V to 16V DC" under Start Battery Input Specifications and "Voltage Range 13V to 30V DC" under Solar Panel Input Specifications.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications, Start Battery Input and Solar Panel Input

Documented

Charge current
40 A
Official instruction manual
Sources

Printed as "Maximum Charging Current 40A".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Enclosure
IP31
Official instruction manual
Sources

Printed as "Enclosure Rating IP31".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

All specs18
Power
616 W
Official instruction manual
Sources

Printed as "Nominal Output Power 616W"; the store page prints "Output Power 616W".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Weight
1.2 kg2.6 lb converted
Official instruction manual
Sources

Printed as "Weight 1.2 kg /2.65 lb".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Charger input
DC and solar (MPPT)
Official instruction manual
Sources

Printed as "Auxiliary Battery Charging Mode MPPT", with "Start Battery Input Specifications" and "Solar Panel Input Specifications" sections; single-model manual (RBC40D1S-G1).

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: PDF page 30, Specifications (General)

Documented

Dimensions
149 W × 48 H × 195 L mm5.87 W × 1.9 H × 7.68 L in converted
Official instruction manual
Sources

Printed as "Dimensions (LxWxH) 195 x 149 x 48 mm / 7.68 x 5.87 x 1.89 inch", read as length, width and height.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Solar input limit
670 W
Official instruction manual
Sources

Printed as "Maximum Input Power 670W" under "Solar Panel Input Specifications" (the start-battery section prints the same line); PDF page 13 also says the array must not exceed 670W.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: PDF page 30, Specifications (Solar Panel Input Specifications)

Documented

Input voltage
Starter battery 7-16 V DC; solar 13-30 V DC
Official instruction manual
Sources

Printed as "Voltage Range 7V to 16V DC" under Start Battery Input Specifications and "Voltage Range 13V to 30V DC" under Solar Panel Input Specifications.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications, Start Battery Input and Solar Panel Input

Documented

Charge current
40 A
Official instruction manual
Sources

Printed as "Maximum Charging Current 40A".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Enclosure
IP31
Official instruction manual
Sources

Printed as "Enclosure Rating IP31".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Engine detection
IGN Signal Wire (for Smart Alternator)
Official instruction manual
Sources

Printed as "4.5. Install a IGN Signal Wire (for Smart Alternator)"; the section adds the wire may instead go to the alternator D+ terminal; single-model manual.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: PDF page 19, 4.5

Documented

Battery voltage
12 V
Official instruction manual
Sources

Printed as "System Voltage 12V".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Maximum input power
670 W
Official instruction manual
Sources

Printed as "Maximum Input Power 670W" for the starter battery input and again for the solar panel input.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications, Start Battery Input and Solar Panel Input

Documented

Max efficiency
93 %
Official instruction manual
Sources

Printed as "Max Chargering Efficiency 93%" (Renogy's spelling) with no load point or test condition.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Solar input voltage
13 to 30 V
Official instruction manual
Sources

Printed as "Voltage Range 13V to 30V DC" under "Solar Panel Input Specifications"; single-model manual.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: PDF page 30, Specifications (Solar Panel Input Specifications)

Documented

Maximum input current
45 A
Official instruction manual
Sources

Printed as "Maximum Input Current 45A ±5%" for each input; the tolerance is Renogy's.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications, Start Battery Input and Solar Panel Input

Documented

Battery chemistry
Sealed/AGM, GEL, FLOOD, LiFePO4
Official instruction manual
Sources

Printed as "Battery Type Sealed/AGM, GEL, FLOOD, LiFePO4".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications, Auxiliary Battery

Documented

Storage temperature
-20 to 60 °C-4 to 140 °F converted
Official instruction manual
Sources

Printed as "Storage Temperature -4°F to 140°F / -20°C to 60°C".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Operating temperature
-20 to 45 °C-4 to 113 °F converted
Official instruction manual
Sources

Printed as "Operating Temperature -4°F to 113°F /-20°C to 45°C".

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Other compliance claims
FCC Path 15, Class B, CE, RoHS, SAA
Official instruction manual
Sources

Recorded exactly as Renogy prints it ("Path" is Renogy's spelling). No certificate, test report or issuer record is linked.

Official instruction manual: Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026 Rev Version A0 (January 1, 2026) · Checked · Earlier document

Location: Section 8, Specifications

Documented

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026OfficialRenogyOfficial instruction manual
    Source details
    Revision
    Version A0 (January 1, 2026)
    Revision date
    Not stated

    Archived copy captured on 2026-10-21.

    Location: Section 8, Specifications (manual page 26, PDF page 30)

    Retrieved

    Renogy's 35-page user manual for the RBC40D1S-G1, Version A0 dated January 1, 2026, linked from the charger's US store page and captured on October 21, 2026. Section 8, Specifications (manual page 26, PDF page 30), is cited. Manufacturer document, not an independent test.

    Archived copies

    Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Version A0 (January 1, 2026) · 7.24 MB

    Archived copy, unaltered, kept as a record of what Renogy published. Original address: https://www.renogy.com/cdn/shop/files/RBC40D1S-G1_RENOGY_CORE_40A_Charger__User_Manual_A0_20260101.pdf?v=16586284203971710104. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    35
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: f6df740469ec39f9e94166c48ee6a97658e9cb2480264e75b5b3f60296638174

    Open
  • WEB
    Renogy US store page: 40A DC-DC Battery Charger with MPPT (October 21, 2026 capture)OfficialRenogyOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-21.

    Location: Store country and currency; product title; specification text

    Retrieved

    Renogy's own US store page (www.renogy.com), captured on October 21, 2026 with the paced research fetcher; the store reports country US and prices in US dollars. Manufacturer claims, not independent tests; the page carries no revision date.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Renogy 12V 40A DC-DC Battery Charger with MPPT (RBC40D1S-G1) User Manual, Version A0, January 1, 2026

Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Version A0 (January 1, 2026) · 7.24 MB

Archived copy, unaltered, kept as a record of what Renogy published. Original address: https://www.renogy.com/cdn/shop/files/RBC40D1S-G1_RENOGY_CORE_40A_Charger__User_Manual_A0_20260101.pdf?v=16586284203971710104. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
35
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: f6df740469ec39f9e94166c48ee6a97658e9cb2480264e75b5b3f60296638174

Submit a document

Warranty

Product warranty
2 years
Official product page
Sources

Printed as "2-year material and workmanship warranty" on Renogy's US store page.

Official product page: Renogy US store page: 40A DC-DC Battery Charger with MPPT (October 21, 2026 capture) Checked · Earlier document

Location: Store page, specification list

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

Listing stated, none checked

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
RBC40D1S-G1

Manufacturer SKU RBC40D1S-US · US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.