EcoFlow AFCI Box

By EcoFlowSKU ASwitchBox-MR500BC

No reviews · Write the first

Key specs

Units
SKU
ASwitchBox-MR500BC
Official product page
Sources

EcoFlow's US store page titled "EcoFlow AFCI Box" prints one variant with SKU ASwitchBox-MR500BC.

Official product page: EcoFlow US store page: EcoFlow AFCI Box (November 3, 2026 capture) Checked · Earlier document

Location: Product data: SKU

Documented

Device type
AFCI/GFCI breaker box
Official user manual
Sources

Printed as "The EcoFlow AFCI/GFCI Box is used for A/GFCI breakers. Each circuit is independent of each other." It is installed indoors with an EcoFlow Smart Home Panel.

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Introduction

Documented

Maximum circuits
10
Official user manual
Sources

Printed as "Number of circuits 10".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Dimensions
11.58 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 348 × H: 127 × D: 262 mmW: 13.7 × H: 5 × D: 10.3 in convertedOfficial user manual
Sources

Printed as "Dimensions (W*D*H) 348*262*127 mm/13.7*10.3*5 (in)".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Calculated

Mounting
Wall Mount
Official user manual
Sources

Printed as "Mounting type Wall Mount".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Rated current (as printed)
10~160A
Official user manual
Sources

Printed as "Rated current 10~160A"; the guide recommends a 2/0 AWG neutral wire (current 160 A).

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Enclosure
Type I; indoor rated
Official user manual
Sources

Printed as "Enclosure Type I" and "Environment Indoor rated".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Voltage rating
120/240V
Official user manual
Sources

Printed as "Rated voltage 120/240V" with "Rated frequency 60Hz".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Operating temperature
-20 to 45 °C-4 to 113 °F converted
Official user manual
Sources

Printed as "Working temperature -20℃~45℃/-4°F-113°F".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

All specs8
Device type
AFCI/GFCI breaker box
Official user manual
Sources

Printed as "The EcoFlow AFCI/GFCI Box is used for A/GFCI breakers. Each circuit is independent of each other." It is installed indoors with an EcoFlow Smart Home Panel.

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Introduction

Documented

Maximum circuits
10
Official user manual
Sources

Printed as "Number of circuits 10".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Dimensions
262 D × 348 W × 127 H mm10.3 D × 13.7 W × 5 H in converted
Official user manual
Sources

Printed as "Dimensions (W*D*H) 348*262*127 mm/13.7*10.3*5 (in)".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Mounting
Wall Mount
Official user manual
Sources

Printed as "Mounting type Wall Mount".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Rated current (as printed)
10~160A
Official user manual
Sources

Printed as "Rated current 10~160A"; the guide recommends a 2/0 AWG neutral wire (current 160 A).

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Enclosure
Type I; indoor rated
Official user manual
Sources

Printed as "Enclosure Type I" and "Environment Indoor rated".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Voltage rating
120/240V
Official user manual
Sources

Printed as "Rated voltage 120/240V" with "Rated frequency 60Hz".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Operating temperature
-20 to 45 °C-4 to 113 °F converted
Official user manual
Sources

Printed as "Working temperature -20℃~45℃/-4°F-113°F".

Official user manual: EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture) Rev V1.0 · Checked · Earlier document

Location: PDF page 1, Product specifications

Documented

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    EcoFlow AFCI Box User Manual V1.0 (November 3, 2026 capture)OfficialEcoFlowOfficial user manual

    Our copy is kept as private evidence and is not available to download. SHA-256: 96b8d862c44cb48c698cc58d8f58286e05ef280e2f7fea46c73ccdf68efabb08, captured .

    Source details
    Revision
    V1.0
    Revision date
    Not stated

    Captured 2026-11-03T20:28:02.520Z (private archived copy).

    Location: PDF page 1, Introduction and Product specifications

    Retrieved

    EcoFlow's AFCI Box user manual V1.0 (2 pages), whose specification table names the product "EcoFlow AFCI/GFCI Box", Model EFD500BC-AB. Fetched directly from the maker's file address on November 3, 2026 (address from EcoFlow's public support download list; robots.txt checked first; request logged 20:28:02.520 UTC). Kept as a private copy only; readers get the maker's own address. Manufacturer claims, not independent tests.

    Open
  • WEB
    EcoFlow US store page: EcoFlow AFCI Box (November 3, 2026 capture)OfficialEcoFlowOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured 2026-11-03T19:58:59.209Z (private archived copy).

    Location: Product data: variant name and SKU

    Retrieved

    EcoFlow's own US store page titled "EcoFlow AFCI Box", whose product data prints variant "Default Title" with SKU ASwitchBox-MR500BC. Fetched directly from us.ecoflow.com with the paced research fetcher on November 3, 2026 (robots.txt checked first; request ended 19:58:59.209 UTC). Read for the product title and the variant name and SKU only; no price or stock state is recorded. Kept as a private copy only. Manufacturer claims, not independent tests.

    Open

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
EFD500BC-AB

Manufacturer SKU ASwitchBox-MR500BC

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.