Charged Reviews
Quick reference
Victron Energy SmartSolar MPPT 250/60-MC4
Model: SmartSolar MPPT 250/60-MC4 · SKU: SCC125060321
Prepared
Common specifications
| Field | Value | Sources |
|---|---|---|
| Controller type | MPPT | [1] [2] |
| Max PV voltage | 250 | [1] [2] |
| Max PV input power | 860 W (12 V) / 1720 W (24 V) / 2580 W (36 V) / 3440 W (48 V) | [2] |
| Max PV input power | 12: 860, 24: 1,720, 36: 2,580, 48: 3,440 W | [2] |
| Max PV current | ? | |
| Charge current | 60 A | [1] [2] |
| Battery voltage | 12/24/48 V Auto Select (software tool needed to select 36 V) | [2] |
| Supported chemistry | Gel long life (OPzV), Gel Exide A600 (OPzV), Gel MK, Gel Victron deep discharge, Gel Exide A200, AGM Victron deep discharge, Stationary tubular plate (OPzS), AGM spiral cell, Rolls AGM, PzS tubular plate traction batteries or OPzS batteries, Lithium Iron Phosphate (LiFePo4) batteries | [1] |
| Efficiency | ? | |
| MPPT tracking efficiency | ? | |
| Max conversion efficiency | 99 % | [1] [2] |
| Full load efficiency | ? | |
| Charger efficiency | ? | |
| Weighted efficiency | ? | |
| Rated charge power | ? | |
| Load output | ? | |
| Self consumption ma | Less than 35 mA @ 12 V / 20 mA @ 48 V | [2] |
| Enclosure rating | IP43 (electronic components), IP22 (connection area) | [2] |
| Listing | EN/IEC 62109-1, UL 1741, CSA C22.2 | [1] |
| Enclosure volume | 5.11 L Calculated | [1] [2] |
| Warranty term | ? |
All recorded specifications
| Field | Value | Sources |
|---|---|---|
| Listing | EN/IEC 62109-1, UL 1741, CSA C22.2 | [1] |
| Grounding | The solar charger can be installed in a positive or in a negative grounded system.; Apply a single ground connection, preferably close to the battery, to prevent system issues or ground loops.; The positive and negative of the PV array should not be grounded.; This charge controller must be used with an external GFDI device as required by the Article 690 of the USA National Electrical Code for the installation location. | [1] |
| Weight | 3 kg / 6.6 lb converted | [1] [2] |
| Clearances | Minimum clearance of 10cm under and above the solar charger | [1] |
| Dimensions | W 250 × H 215 × D 95 mm / W 9.84 × H 8.46 × D 3.7 in converted | [1] [2] |
| PV disconnect | Provide a means to disconnect all current-carrying conductors of a photo-voltaic power source from all other conductors in a building or other structure. | [1] |
| Communications | VE.Direct or Bluetooth | [2] |
| Controller type | MPPT | [1] [2] |
| Charge current | 60 A | [1] [2] |
| Enclosure rating | IP43 (electronic components), IP22 (connection area) | [2] |
| Max PV voltage | 250 | [1] [2] |
| Battery voltage | 12/24/48 V Auto Select (software tool needed to select 36 V) | [2] |
| Battery wire size | 35 mm² / AWG2 | [1] |
| Battery protection | Battery fuse: minimum 70A, maximum 80A | [1] |
| Max PV input power | 860 W (12 V) / 1720 W (24 V) / 2580 W (36 V) / 3440 W (48 V) | [2] |
| Communication ports | VE.Direct socket | [1] |
| Self consumption ma | Less than 35 mA @ 12 V / 20 mA @ 48 V | [2] |
| Supported chemistry | Gel long life (OPzV), Gel Exide A600 (OPzV), Gel MK, Gel Victron deep discharge, Gel Exide A200, AGM Victron deep discharge, Stationary tubular plate (OPzS), AGM spiral cell, Rolls AGM, PzS tubular plate traction batteries or OPzS batteries, Lithium Iron Phosphate (LiFePo4) batteries | [1] |
| Max PV input power | 12: 860, 24: 1,720, 36: 2,580, 48: 3,440 W | [2] |
| Mounting orientation | Vertically on a non-flammable substrate, with the electrical terminals facing downwards | [1] |
| Battery terminal torque | 2.4 N·m | [1] |
| Operating temperature | -30 to +60 °C (full rated output up to 40 °C) | [2] |
| Max conversion efficiency | 99 % | [1] [2] |
Warranty
No warranty facts recorded.
Certificate records
| Standard | Record | Evidence | Sources |
|---|---|---|---|
| EN/IEC 62109-1 | Claimed · present at observation | [2] | |
| UL 1741 | Claimed · present at observation | [2] | |
| CSA C22.2 | Claimed · present at observation | [2] |
Sources and revisions
- Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026) https://www.victronenergy.com/upload/documents/Manual_SmartSolar_MPPT_150-60_up_to_250-70/29694-MPPT_solar_charger_manual-pdf-en.pdf
- SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture) https://www.victronenergy.com/upload/documents/Datasheet-SmartSolar-charge-controller-MPPT-250-60-and-250-70-EN.pdf