About brandOutBack Power's About page says the company has made battery-based power equipment since 2001, including off-grid inverter/chargers, grid-interactive inverter systems, MPPT charge controllers and energy storage. It says OutBack Power is now part of Energy Access Innovations (EAI). Its datasheets name OutBack Power Technologies, Inc. of Phoenix, Arizona.
SKU detail
locator: Models line
conditions: Printed as the datasheet's own model designation for the FLEXmax 80.
UL 1741 2nd Edition, CSA C22.2 No. 107.1-01, IEC 62509:2010
Printed as "Regulatory Specifications for All Models UL 1741 2nd Edition CSA C22.2 No. 107.1-01 IEC 62509:2010" in Table 3 of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020). The electrical specifications on the same page also print "150 Vdc maximum (ETL Rating for UL1741 Standard)". Manufacturer claim as printed.
Where: PDF page 95, Table 3 Regulatory Specifications for All Models
This product is intended to be installed as part of a permanently grounded electrical system; The negative battery conductor should be bonded to the grounding system at only one point in the system.; The FLEXmax controller is not intended to be wired into a positive-ground configuration.
Printed as "The negative battery conductor should be bonded to the grounding system at only one point in the system." in the Grounding section of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020), with the other quoted sentences; the section adds that with a GFDI present the battery negative and ground are connected by the GFDI device.
Up to #2 AWG (33.6 mm2); input conductors rated at 1.56 times the PV array short-circuit current (NEC)
Printed as "Input conductors and circuit breakers must be rated at 1.56 times the short-circuit current of the PV array (according to NEC)." in OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020), with "Use up to #2 AWG (33.6 mm2) to reduce losses and ensure high performance of the FLEXmax" in the same section. No fixed PV conductor size is printed.
W 146 × H 412.8 × D 101.6 mm / W 5.75 × H 16.25 × D 4 inCheck note
OutBack's manual and datasheet print different depths for the FLEXmax 80. OutBack Power's FLEXmax Series owner's manual (Rev D, January 2020) prints the FLEXmax 80 as 16.25 inches high, 5.75 inches wide and 4 inches deep (its figure gives 4.0 inches as 10.2 cm), while OutBack's FLEXmax 80 datasheet (2026) prints 41.3 × 14.6 × 11.4 cm. Both are OutBack documents; the manual's figure is shown first and the datasheet's is kept beside it.
Printed as "Dimensions 13.5” H × 5.75” W × 4” D 16.25” H × 5.75” W × 4”D" in OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020); the second entry is the FLEXmax 80 column. The dimension figure on PDF page 10 labels the FLEXmax 80 "16.25” (41.3 cm)" tall, with "4.0” (10.2 cm)" and "5.75” (14.6 cm)" for the shared depth and width. Revised on 1 October 2026: The owner's manual, which outranks the datasheet, prints a depth of 4 inches (10.2 cm) for the FLEXmax 80, while the 2026 datasheet prints 11.4 cm; height and width agree. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (height x width x depth).
Where: PDF page 95, Electrical and Mechanical Specifications, Dimensions row, FLEXmax 80 column; PDF page 10, Figure 3
Sources
Converted: 16.25 x 5.75 x 4 in x 25.4 mm/in, rounded to 0.1 mm
W 146 × H 413 × D 114 mm
Printed as this model's own unit dimensions, excluding shipping packaging. Printed as "Dimensions H x W x D (in/cm): Unit: 16.25 × 5.75 × 4.5 / 41.3 × 14.6 × 11.4" in OutBack Power's FLEXmax 80 datasheet. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (height x width x depth).
Install OutBack PNL-80-DC circuit breakers for disconnect and overcurrent protection; Input conductors and circuit breakers must be rated at 1.56 times the short-circuit current of the PV array (according to NEC).
Printed as "Install OutBack PNL-80-DC circuit breakers for disconnect and overcurrent protection" in the FLEXmax 80 list of the Wire and Disconnect Sizing section of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020), which also prints the 1.56 times rule for input circuit breakers. The section does not split the breakers between the PV and battery sides.
Where: PDF page 12, Wire and Disconnect Sizing, FLEXmax 80 list
Printed as "The FLEXmax Charge Controllers use continuous Maximum Power Point Tracking (MPPT)" in OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Printed as "Output Current Rating @ 40°C ambient 60 amps continuous 80 amps continuous" in OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020); 80 amps is the FLEXmax 80 column. PDF page 7 prints "FLEXmax 80: 80 amps maximum continuous output current". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Where: PDF page 95, Electrical and Mechanical Specifications, Output Current Rating row, FLEXmax 80 column; PDF page 7, Features
Printed as "Use up to 35 mm2 (#2 AWG) wire" for the Chassis/Equipment Ground Lug in the wiring compartment figure of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020).
Where: PDF page 13, Wiring Compartment, Chassis/Equipment Ground Lug
Printed as "PV Open Circuit Voltage (Voc) 150 Vdc maximum (ETL Rating for UL1741 Standard); 145 Vdc temperature corrected Voc (operational maximum)" in OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020), one entry for both models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Where: PDF page 95, Electrical and Mechanical Specifications, PV Open Circuit Voltage (Voc) row
Sources
145 VDC
Printed as this model's own start-up and operating maximum PV open circuit voltage, distinct from its absolute maximum in coldest conditions.
Minimum #4 AWG (25 mm2) between the FLEXmax 80 and the battery bus bar; up to #2 AWG (33.6 mm2)
Printed as "Use a minimum of #4 AWG (25 mm2) wire for the output between the FLEXmax 80 and the battery bus bar conductors." in the FLEXmax 80 list of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020); the same section prints "Use up to #2 AWG (33.6 mm2) to reduce losses and ensure high performance of the FLEXmax" and asks for copper wiring rated at 75°C or higher.
DC battery overcurrent protection must be used as part of the installation.; Install OutBack PNL-80-DC circuit breakers for disconnect and overcurrent protection
Printed as "DC battery overcurrent protection must be used as part of the installation." on PDF page 9 of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020), and as "Install OutBack PNL-80-DC circuit breakers for disconnect and overcurrent protection" in the FLEXmax 80 list on PDF page 12.
Where: PDF page 9, DC / Battery-Related Installation Requirements; PDF page 12, FLEXmax 80 list
Printed as this model's own NEC-recommended solar maximum array rating on a 48VDC system, the controller's default nominal voltage; the 12V, 24V and 60V system figures are kept as alternatives.
Where: Models block, NEC Recommended Solar Maximum Array STC Nameplate row
Sources
1000 W W
Printed as this model's own recommended maximum array rating on a 12VDC system.
Printed as "Torque all the FLEXmax wire lugs and ground terminals to 4 Nm (35 in-lb)." in the FLEXmax 80 list of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020) and again on PDF page 9; one figure for all wire lugs and ground terminals, recorded on the PV, battery and ground terminal keys. Printed in two units, newton meters first ("4 Nm", then "35 in-lb").
Where: PDF page 12, Wire and Disconnect Sizing, FLEXmax 80 list; PDF page 9, DC / Battery-Related Installation Requirements
MATE/HUB RJ45 port; Battery Remote Temp Sensor (RTS) RJ11 port
Printed as "MATE/HUB RJ45 port" and "Battery Remote Temp Sensor (RTS) RJ11 port" in the wiring compartment figure of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020); the figure also names the Auxiliary Output (AUX) terminals.
Printed as "IMPORTANT: Install the FLEXmax in an upright position out of direct sunlight." in OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020). PDF page 9 adds that the controller is designed for indoor installation or installation inside a weatherproof enclosure.
Where: PDF page 11, Mounting the Charge Controller; PDF page 9, Standards and Requirements
Printed as "Torque to 4 Nm (35 in-lb)" for the Chassis/Equipment Ground Lug in OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020), and as "Torque all the FLEXmax wire lugs and ground terminals to 4 Nm (35 in-lb)." on PDF page 12. Printed in two units, newton meters first.
Where: PDF page 13, Wiring Compartment, Chassis/Equipment Ground Lug; PDF page 12, FLEXmax 80 list
Printed as "Torque all the FLEXmax wire lugs and ground terminals to 4 Nm (35 in-lb)." in the FLEXmax 80 list of OutBack Power's FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D, January 2020) and again on PDF page 9; one figure for all wire lugs and ground terminals, recorded on the PV, battery and ground terminal keys. Printed in two units, newton meters first ("4 Nm", then "35 in-lb").
Where: PDF page 12, Wire and Disconnect Sizing, FLEXmax 80 list; PDF page 9, DC / Battery-Related Installation Requirements
Printed as "Peak Efficiency: 60VDC input w/48V battery at 53.1VDC (98.44%)" in OutBack Power's FLEXmax 80 data sheet. The same block prints "Power Conversion Efficiency: 97.5% @ 80ADC in a 48VDC system (typical)" and "CEC Weighted Efficiency: 97.3% (at 48VDC)". Revised on 13 October 2026: the value was 97.5, the typical power conversion efficiency at 80ADC in a 48VDC system; it is now the printed peak efficiency, 98.44.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
FLEXmax 80
Limitations
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No. 107.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
FLEXmax 80
Limitations
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Location: PDF page 1 cover; PDF page 7, Features ("The FLEXmax Series has two models available")
Retrieved Oct 1, 2026
OutBack Power's own owner's manual with installation instructions for the FLEXmax Series charge controllers, captured 1 October 2026 from outbackpower.com, where the FLEXmax 60/80 product page links it as the Owner Manual; January 2020, Revision D as printed; it names the FLEXmax 80 and FLEXmax 60 (FM80 and FM60) but does not print the FM80-150VDC part number. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No. 107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Primary source for the FLEXmax 80 (FM80-150VDC): names this exact model and part number.
Archived copies
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
OutBack Power's own FLEXmax 80 Specifications datasheet, dated 2026, linked from OutBack Power's own outbackpower.com FLEXmax 60/80 product page.
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
OutBack Power FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D)
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].