| Listing | UL1741; CSA C22.2 No. 107.1-16; IEC 62109-1:2010 | [1] |
|---|
| Grounding | This product is intended to be installed as part of a permanently grounded electrical system.; The product comes with a functional bond established from negative to ground.; The battery conductor (positive or negative) must be bonded to the grounding system at only one point.; Make certain to connect the FLEXmax grounding terminal bus bar to earth ground. | [1] |
|---|
| Weight | 7.3 kg | [2] |
|---|
| PV wire size | Input conductors rated at 1.56 times the PV array short-circuit current (NEC) | [1] |
|---|
| Clearances | Above the ground or floor surface: 36” (91.4 cm) Above and below the controller: 6“ (15.2 cm) Right and left sides: 1” (2.5 cm) | [1] |
|---|
| Dimensions | W 224 × H 584 × D 152 mm / W 8.8 × H 23 × D 6 in | [2] |
|---|
| PV disconnect | Input conductors and circuit breakers must be rated at 1.56 times the short-circuit current of the PV array (per NEC).; PNL-40-300VDC 40 amp single pole; PNL-40D-300VDC 40 amp double pole; PNL-60-300VDC 60 amp single pole; PNL-60D-300VDC 60 amp double pole; PNL-80-300VDC 80 amp single pole; PNL-80D-300VDC 80 amp double pole | [1] |
|---|
| Communications | Proprietary network system using RJ-45 modular connectors | [2] |
|---|
| Controller type | MPPT | [1] [2] |
|---|
| Charge current | 100 A | [1] [2] |
|---|
| Enclosure rating | IP54 | [1] [2] |
|---|
| Ground wire size | Up to #6 AWG (16 mm2), 90°C copper | [1] |
|---|
| Max PV current | 64 A | [1] |
|---|
| Max PV voltage | 300 VDC | [1] [2] |
|---|
| Battery voltage | 24VDC / 36VDC / 48VDC | [2] |
|---|
| Battery wire size | #4 AWG (25 mm2) minimum; accepts up to #2 AWG (35 mm2); 90°C copper | [1] |
|---|
| Battery protection | DC battery overcurrent protection must be used as part of the installation.; PNL-100-300VDC 100 amp single pole with plastic shield; PNL-125-300VDC 125 amp single pole with plastic shield; The minimum AIC (amps interrupting capacity) rating required is 1125 Adc. | [1] |
|---|
| Max PV input power | 7000 W | [1] [2] |
|---|
| PV terminal torque | 4 N·m | [1] |
|---|
| Communication ports | HUB Port (RJ-45); Remote Temperature Sensor Port; Device and LAN Ports (not currently active) | [1] |
|---|
| Max PV input power | 24: 3,500, 36: 5,250, 48: 7,000 W | [1] [2] |
|---|
| Mounting orientation | Upright on a wall or similar flat upright mounting surface; no other mounting positions are allowed | [1] |
|---|
| Ground terminal torque | 4 N·m | [1] |
|---|
| Battery terminal torque | 4 N·m | [1] |
|---|
| Operating temperature | –25° to 60°C | [2] |
|---|
| Weighted efficiency | 97.3 % | [2] |
|---|
| Max conversion efficiency | 98.8 % | [2] |
|---|