About brandOutBack Power's About page says the company has made battery-based power equipment since 2001, including off-grid inverter/chargers, grid-interactive inverter systems, MPPT charge controllers and energy storage. It says OutBack Power is now part of Energy Access Innovations (EAI). Its datasheets name OutBack Power Technologies, Inc. of Phoenix, Arizona.
SKU detail
locator: Model line
conditions: Printed as the datasheet's own model designation; Greentech Renewables' own listing carries the same designation as its part number.
Printed as "This product carries a listing report by ETL. It is listed to the following standards:" in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), followed by UL1741 (Ed: 2) and CSA C22.2 No. 107.1-16 (Ed:4); PDF page 68 prints "This product is certified to the following standards:" followed by IEC 62109-1:2010. Manufacturer claim as printed.
Where: PDF page 67, Regulatory Specifications, Listings; PDF page 68, Certifications
This product is intended to be installed as part of a permanently grounded electrical system.; The product comes with a functional bond established from negative to ground.; The battery conductor (positive or negative) must be bonded to the grounding system at only one point.; Make certain to connect the FLEXmax grounding terminal bus bar to earth ground.
Printed as "The product comes with a functional bond established from negative to ground." in the Grounding section of OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), with the other quoted sentences; the controller includes internal ground-fault protection, and PDF page 19 sets out the steps for a positive-ground system (remove the bonding jumper, external positive-to-ground bond, external GFDI).
Where: PDF page 18, Wiring, Grounding; PDF page 19, Positive-Ground Systems
Input conductors rated at 1.56 times the PV array short-circuit current (NEC)
Printed as "Input conductors and circuit breakers must be rated at 1.56 times the short-circuit current of the PV array (per NEC)." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), which refers to the NEC and other codes for PV array cable sizing. No fixed PV conductor size is printed.
Above the ground or floor surface: 36” (91.4 cm) Above and below the controller: 6“ (15.2 cm) Right and left sides: 1” (2.5 cm)
Printed as "Clearance requirements (minimum) Above the ground or floor surface: 36” (91.4 cm) Above and below the controller: 6“ (15.2 cm) Right and left sides: 1” (2.5 cm)" in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), which adds "This includes clearance for multiple controllers installed next to each other."
Where: PDF page 15, Dimensions and Clearances, Clearance requirements (minimum)
Printed as this model's own unit dimensions, excluding shipping packaging; the datasheet notes the height figure includes the cooling fan. Printed as "Dimensions H × W × D (in/cm)*: Unit: 23 × 8.8 × 6 / 58.4 × 22.4 × 15.2" in OutBack Power's FLEXmax 100 AFCI datasheet. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (height x width x depth).
Input conductors and circuit breakers must be rated at 1.56 times the short-circuit current of the PV array (per NEC).; PNL-40-300VDC 40 amp single pole; PNL-40D-300VDC 40 amp double pole; PNL-60-300VDC 60 amp single pole; PNL-60D-300VDC 60 amp double pole; PNL-80-300VDC 80 amp single pole; PNL-80D-300VDC 80 amp double pole
Printed as "The input (PV) and output protective devices must be sized according to the installation requirements." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), followed by the quoted Input Circuit Breakers list. PDF page 19 adds that a positive-ground system needs a dual-pole PV input circuit breaker.
Where: PDF page 21, Circuit Breaker Size and Requirements, Input Circuit Breakers
Printed as "maximum power point tracking charge controllers" in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), whose cover names this model as a charge controller. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Where: PDF page 2, About OutBack Power; PDF page 1, cover
Printed as "Maximum Continuous Output Current 100 Adc" in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Where: PDF page 67, Table 10 Electrical and Mechanical Specifications, Maximum Continuous Output Current row
Printed as "Ingress Protection Rating IP54" in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022); the same table also prints "Enclosure Type Type 3R". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Printed as "The maximum permitted conductor size for connection to the grounding wire terminal block is #6 AWG (16 mm2)." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), followed by "Use 90°C copper wire."
Printed as "Maximum Input Current (short-circuit) 64 Adc" in Table 10 of OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022); the figure is printed as a short-circuit input current, and PDF page 21 adds that the largest PV array must have a rated short-circuit current of 64 amps or less under STC.
Where: PDF page 67, Table 10 Electrical and Mechanical Specifications, Maximum Input Current (short-circuit) row
Printed as "PV Open-Circuit Voltage 300 Vdc (highest open-circuit voltage before equipment damage)" in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022); the operating maximum is printed separately as 290 Vdc temperature corrected Voc. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Where: PDF page 67, Table 10, PV Open-Circuit Voltage row
#4 AWG (25 mm2) minimum; accepts up to #2 AWG (35 mm2); 90°C copper
Printed as "Use #4 AWG (25 mm2) wire (minimum) for the output between the FLEXmax 100 and the battery bus bar conductors." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), with "The output can accept conductors up to #2 AWG (35 mm2)." and "Use 90°C copper wire."
DC battery overcurrent protection must be used as part of the installation.; PNL-100-300VDC 100 amp single pole with plastic shield; PNL-125-300VDC 125 amp single pole with plastic shield; The minimum AIC (amps interrupting capacity) rating required is 1125 Adc.
Printed as "DC battery overcurrent protection must be used as part of the installation." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), which lists OutBack's output circuit breakers as the quoted PNL-100-300VDC and PNL-125-300VDC models and prints the minimum AIC rating.
Where: PDF page 21, Wiring Size and Requirements; Circuit Breaker Size and Requirements, Output Circuit Breakers
Printed as "24 V 3500 W 36 V 5250 W 48 V 7000 W" in Table 13 (Maximum Array Size, Standard Test Conditions) of OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022); the recorded 7000 W is the 48 V row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to OutBack Power (outbackpower.com), which stays listed as an additional source.
Where: PDF page 73, Table 13 Maximum Input Wattage Per Charge Controller, 48 V row
Sources
3500 W W
Printed as this model's own maximum array rating at 24V nominal battery voltage.
Printed as "All wire lugs and ground terminals are to be tightened to a torque value of 4 Nm (35 in-lb)." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022); one figure for all wire lugs and ground terminals, recorded on the PV, battery and ground terminal keys. Printed in two units, newton meters first ("4 Nm", then "35 in-lb").
Where: PDF page 22, Physical Requirements and Conduit
HUB Port (RJ-45); Remote Temperature Sensor Port; Device and LAN Ports (not currently active)
Printed as "HUB Port This is an RJ-45 port for a CAT5-style cable to connect OutBack Power system displays or the HUB communications manager." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), which also names the Remote Temperature Sensor Port and prints "Device and LAN Ports These ports are not currently active."; a MicroSD card slot and an accessory terminal block are also shown.
Printed as "Nominal Battery Voltage Maximum Array Size (Standard Test Conditions) 24 V 3500 W 36 V 5250 W 48 V 7000 W" in Table 13 of OutBack Power's FLEXmax 100 Owner's Manual (900-0253-01-00 Rev C); the data sheet prints "Maximum Array (STC Nameplate): 3500W / 5250W / 7000W (charging output limited to 100A at battery voltage)".
Where: PDF page 73, Table 13 Maximum Input Wattage Per Charge Controller
Upright on a wall or similar flat upright mounting surface; no other mounting positions are allowed
Printed as "The FLEXmax 100 must be mounted upright on a wall or similar flat upright mounting surface. No other mounting positions are allowed." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022), which adds "Installation in shade is recommended."
Where: PDF page 16, Mounting the Charge Controller
Printed as "All wire lugs and ground terminals are to be tightened to a torque value of 4 Nm (35 in-lb)." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022); one figure for all wire lugs and ground terminals, recorded on the PV, battery and ground terminal keys. Printed in two units, newton meters first ("4 Nm", then "35 in-lb").
Where: PDF page 22, Physical Requirements and Conduit
Printed as "All wire lugs and ground terminals are to be tightened to a torque value of 4 Nm (35 in-lb)." in OutBack Power's FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C, June 2022); one figure for all wire lugs and ground terminals, recorded on the PV, battery and ground terminal keys. Printed in two units, newton meters first ("4 Nm", then "35 in-lb").
Where: PDF page 22, Physical Requirements and Conduit
Printed as "Peak Efficiency: 24V: 97.5% 48V: 98.8%" in OutBack Power's FLEXmax 100 AFCI data sheet; 98.8% is the 48V figure, the higher of the two, and the 24V figure is kept as an alternative. The same block prints "Power Conversion Efficiency: 24V: 96% 48V: 97%". Revised on 13 October 2026: the value was 97, the power conversion efficiency at 48V; it is now the printed peak efficiency at 48V, 98.8.
Where: Model block, Peak Efficiency row, 48V
Sources
97.5 %
Printed as this model's peak efficiency at 24V nominal battery voltage.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
FLEXmax 100 AFCI
Limitations
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No. 107.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
FLEXmax 100 AFCI
Limitations
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
FLEXmax 100 AFCI
Limitations
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Location: PDF page 1 cover; PDF page 2, Applicability
Retrieved Oct 1, 2026
OutBack Power's own owner's manual with installation instructions for the FLEXmax 100 charge controller, captured 1 October 2026 from old.outbackpower.com, linked as the Owner's Manual from OutBack's current FLEXmax 100 AFCI product page; June 2022, Revision C as printed; its cover names FM100-300VDC-01 and FM100-300VDC-AFCI. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No. 107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109-1Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications row, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: Model / electrical / mechanical / certifications block
Retrieved Sep 27, 2026
Primary source for the FLEXmax 100 AFCI (FM100-300VDC-AFCI): names this exact model.
Archived copies
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
OutBack Power's own FLEXmax 100 AFCI Specifications datasheet, document 980-00078-01-001 REV C, dated October 2021, linked from OutBack Power's own outbackpower.com FLEXmax 100 AFCI product page.
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
OutBack Power FLEXmax 100 Charge Controller FM100-300VDC-01 FM100-300VDC-AFCI Owner's Manual (900-0253-01-00 Rev C)
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].