About brandMorningstar Corporation, based in Newtown, Pennsylvania since 1993, makes solar charge controllers and inverters used in off-grid, industrial and hazardous-location power systems worldwide; its datasheets describe the company as employee-owned with well over three million products made.
SKU detail
locator: Versions line
conditions: Printed as this model's own version designation (the meter-equipped "M" suffix versions, PS-MPPT-25M and PS-MPPT-40M, are built as separate records: same electrical specifications, only a factory-fitted meter).
Printed as "UL1741 INVERTERS, CONVERTERS, AND CONTROLLERS AND INTERCONNECTION SYSTEM EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY SOURCES" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), the ProStar MPPT Addendum to Operator's Manual, Certifications, a list for the ProStar MPPT. UL121201/CSA C22.2 #213 covers Class I, Division 2 hazardous locations. These are the maker's claims as printed, not checked against the listing bodies' directories.
Use copper wire to connect the grounding terminal in the case, and other dead metal, to earth ground.; DO NOT bond DC system electrical negative to earth grounding terminal on the controller.
Printed as "Use copper wire to connect the grounding terminal in the case, and other dead metal, to earth ground." in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Step 4, a statement for all ProStar MPPT models. The manual says the unit has no internal ground fault protection and must be used with an external GFDI device where Article 690 of the National Electrical Code requires one.
Where: PDF page 20, section 3.4.3, Step 4 (Grounding and Ground Fault Interruption)
#14 - 2 AWG (2.5 - 33.6 mm2); maximum #6 AWG (16 mm2) with the standard terminal cover
Printed as "The power terminals are sized for #14 - 2 AWG (2.5 - 33.6 mm2) wire." in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.1, a statement for all ProStar MPPT power terminals. Up to #2 AWG only inside an enclosure or with the Wiring Box accessory. The manual requires PV wire ampacity of at least 156% of the PV array Isc.
at least 15 cm (6 in) of space above and below the controller, and 50 mm (2 in) at the sides
Printed as "allow at least 15 cm (6 in) of space above and below the controller, and 50 mm (2 in) at the sides" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.3, a statement for all ProStar MPPT models.
W 200 × L 194 × D 70 mm / W 7.87 × L 7.62 × D 2.76 inCheck note
The manual and the data sheet print different dimensions. Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8) prints 20.0(W) x 19.4(L) x 7.0(D) cm for the standard version; Morningstar's ProStar MPPT data sheet prints 20 x 17 x 7 cm.
Printed as "Dimensions: Standard 7.87(W) x 7.62(L) x 2.76(D) in. / 20.0(W) x 19.4(L) x 7.0(D) cm" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, the Standard version (without the Wire Box option). With the Wire Box option the manual prints 20.0 (W) x 28.5 (L) x 9.2(D) cm. Revised on 1 October 2026: The installation and operation manual is the primary source; its standard-version length (19.4 cm) differs from the data sheet figure (17 cm). Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (width x length x depth).
Where: PDF page 40, section 7.0, Mechanical, Dimensions: Standard row
Sources
Converted: 20 x 19.4 x 7 cm x 10 mm/cm
20 × 17 × 7 cm
Printed as a single standard-enclosure value shared across both models; a wire-box option changes this figure.
Printed as "Load Current Rating 25 Amps 30 Amps" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0; 30 Amps is the PS-MPPT-40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 40, section 7.0, Electrical, Load Current Rating row, PS-MPPT-40 column
Printed as "Maximum PV breaker or fuse ratings are:" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.2, the maximum PV breaker or fuse rating for the PS-MPPT-40. PV input disconnect switches must be rated at least 1.25 times the PV array Isc.
Where: PDF page 17, section 3.4.2, PV input disconnect and over-current protection device sizing
The manual and the data sheet print different peak efficiencies. Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8) prints a peak conversion efficiency of 97.3%; Morningstar's ProStar MPPT data sheet prints 98%.
Printed as "Conversion Efficiency (peak) All: 97.3%" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models. Revised on 1 October 2026: The installation and operation manual is the primary source; it prints a peak conversion efficiency of 97.3%, while the data sheet prints 98%.
Printed as "Max. Battery Current 25 Amps 40 Amps" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0; 40 Amps is the PS-MPPT-40 column (columns PS-MPPT-25, PS-MPPT-40). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 40, section 7.0, Electrical, Max. Battery Current row, PS-MPPT-40 column
Printed as "ProStar MPPT-40 10 AWG (5 mm2)" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Step 4, the minimum equipment copper grounding wire size per NEC printed for the ProStar MPPT-40. Per IEC 62109 the manual prints "ProStar MPPT-40 7 AWG (10 mm2)", or a wire of the same or greater cross-sectional area as the PV wires.
Where: PDF page 20, section 3.4.3, Step 4 (Grounding and Ground Fault Interruption)
Printed as "Max. PV Open-Circuit Voltage All: 120 Volts" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 40, section 7.0, Electrical, Max. PV Open-Circuit Voltage row
Printed as "PS-MPPT 40 8 AWG 6 AWG > 35°C 4 AWG > 45°C 8 AWG 8 AWG 10-18" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Table C-1, the PS-MPPT-40 row (columns: wire size in a raceway, cable, or earth at 30ºC and 30º-60ºC; in free air at 30ºC and 30º-45ºC; metric size in mm2). Minimum sizes for 75ºC or 90ºC rated stranded copper. Section 3.4.1 (PDF page 15) says the power terminals are sized for #14 - 2 AWG (2.5 - 33.6 mm2) wire, with #6 AWG the maximum under the standard terminal cover.
Where: PDF page 44, Appendix C, Table C-1 (Minimum DC battery wire sizes), PS-MPPT-40 row
Printed as "PS-MPPT-40: 50 Amps" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.2, the recommended battery circuit fuse or breaker rating for the PS-MPPT-40. Section 3.1 (PDF page 13) requires over-current protection interrupt ratings of at least 2000A for 12V systems and 4000A for 24V systems.
Where: PDF page 17, section 3.4.2, Battery disconnect and over-current protection device sizing
Printed as this model's own nominal output power and max recommended solar PV input on a 24 volt battery, the higher of the two nominal voltages; the 12 volt battery figure is kept as an alternative.
Where: Electrical block, Nominal Maximum Output Power / Max Recommended Solar PV Input row
Sources
550W / 700W W
Printed as this model's own nominal output power and max recommended solar PV input on a 12 volt battery.
Printed as "torque tightly up to 35 in-lb" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.1, for all ProStar MPPT power terminals. Section 7.0 (PDF page 40) prints "Maximum torque 35 in-lb" for the power terminals.
Printed as "Self-Consumption All: ~0.6W (no meter) ~1.0W (w/backlit meter)" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models. The manual states self-consumption in watts, not milliamps.
Where: PDF page 40, section 7.0, Electrical, Self-Consumption row
Printed as "off-off-off 1 - Sealed* 14.00" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Table 3.1, the battery types selectable with DIP switches 4, 5 and 6. The table's footnote says the "Sealed" battery type includes gel and AGM batteries.
Where: PDF page 14, section 3.2, Table 3.1 (battery charging settings for each selectable battery type)
Printed in the "Nominal Maximum Output Power / Max Recommended Solar PV Input" rows of Morningstar's ProStar MPPT data sheet: "12 volt battery 550W / 700W" and "24 volt battery 1100W / 1400W" in the PS-MPPT-40 column; the second figure of each pair is the max recommended solar PV input. Footnote: "The PV array power rating may exceed the controller's Max Nominal Output Power specification."
Where: Electrical block, Nominal Maximum Output Power / Max Recommended Solar PV Input rows, PS-MPPT-40 column
Printed as "Mount the ProStar MPPT to a vertical surface" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.3, a statement for all ProStar MPPT models.
Printed as "torque tightly up to 35 in-lb" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.1, for all ProStar MPPT power terminals. Section 7.0 (PDF page 40) prints "Maximum torque 35 in-lb" for the power terminals.
Printed as "Battery Voltage Range All: 10-35 Volts" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models.
Where: PDF page 40, section 7.0, Electrical, Battery Voltage Range row
Printed as "T4 Certified -40°C to +60°C T5 Certified -40°C to +45°C" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, Ambient Temperature Range, the T4 Certified figure; printed once for all ProStar MPPT models. The T5 Certified range is -40°C to +45°C. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 41, section 7.0, Environmental, Ambient Temperature Range
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
prostar-mppt-40
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No.107.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
prostar-mppt-40
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109-1manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-40
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Part-15 Class Bmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-40
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
UL121201/CSA C22.2 #213manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-40
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Location: Cover page (MODELS list) and section 7.0 (Technical Specifications)
Retrieved Oct 1, 2026
Morningstar's own installation, operation and maintenance manual for the ProStar MPPT models PS-MPPT-25, PS-MPPT-25M, PS-MPPT-40 and PS-MPPT-40M, captured 1 October 2026 from morningstarcorp.com, where the product page links it; revision MS-001537 v3.8 as printed on the back cover. Manufacturer instructions and specifications, not independent tests.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No.107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109-1Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Part-15 Class BManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
UL121201/CSA C22.2 #213Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
ATEXManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IECExManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: Versions table and Technical Specifications block
Retrieved Sep 27, 2026
Primary source for the ProStar MPPT models.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Morningstar's own ProStar MPPT datasheet, control #MS-001724 REV 01/2025.EN, from morningstarcorp.com's own ProStar MPPT product page.
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Morningstar ProStar MPPT Solar Charging System Controller Installation, Operation and Maintenance Manual (MS-001537 v3.8)
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].