About brandMorningstar Corporation, based in Newtown, Pennsylvania since 1993, makes solar charge controllers and inverters used in off-grid, industrial and hazardous-location power systems worldwide; its datasheets describe the company as employee-owned with well over three million products made.
SKU detail
locator: MODELS row
conditions: Printed as this model's own column heading.
Do not connect the negative system wire to the case grounding terminal.; the system electrical negative must be bonded through a GFPD to earth ground at only one point
Printed as "Do not connect the negative system wire to the case grounding terminal." in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 2.5.3, a statement for all GenStar MPPT models. The same section says the GenStar MPPT does not have internal ground fault protection.
Where: PDF page 37, section 2.5.3 (Grounding and Ground Fault Interruption)
Printed as "Battery and PV input terminals 10 - 53.5 mm2 / #8 - 1/0 AWG" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), the wire size range the battery and PV input terminals accept, printed once for all three models. The manual's appendix requires PV wire ampacity of at least 156% of the PV array Isc without correction factors.
Where: PDF page 151, section 8.0, Mechanical table, Wire Size Range, Battery and PV input terminals row
at least 6" (150 mm) of space above and below the unit, and at least 3" (75 mm) around the heatsink
Printed as "Verify that there is at least 6" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 2.3 Mounting, Step 2 (6 and 3 inches), a statement for all GenStar MPPT models.
Where: PDF page 24, section 2.3 (Mounting), Step 2
W 222 × H 360.4 × D 170.2 mm / W 8.75 × H 14.2 × D 6.7 in
Printed as a single value shared across all three amperages. Printed as "Product Dimensions (H x W x D) 14.2 x 8.75 x 6.70 in / 360.4 x 222 x 170.2 mm" in Morningstar's GenStar MPPT datasheet. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (height x width x depth).
Printed as "Maximum Load Current 30 Amps 30 Amps 30 Amps" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Electrical table; 30 Amps in the GS-MPPT-100M-200V column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 150, section 8.0, Electrical table, Maximum Load Current row, GS-MPPT-100M-200V column
Printed as "Maximum PV breaker or fuse ratings are:" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), Table 2, the maximum PV input breaker or fuse rating on the GS-MPPT-100M-200V row. The manual says the PV input breaker or fuse rating should not be less than the next higher breaker rating above 156% of the PV array Isc.
Where: PDF page 28, section 2.4, Table 2 (PV Input Circuit Maximum Breaker or Fuse Current Ratings)
Printed as "MPPT Operating Voltage Range ALL: > battery voltage + 1 Volt; < 180 Volts" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Electrical table, printed once for all three models.
Where: PDF page 150, section 8.0, Electrical table, MPPT Operating Voltage Range row
Printed as "Maximum Battery Charge Current 60 Amps 80 Amps 100 Amps" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Electrical table; 100 Amps is the GS-MPPT-100M-200V column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 150, section 8.0, Electrical table, Maximum Battery Charge Current row, GS-MPPT-100M-200V column
Printed as "Max. Input Current (Imp/Isc) 56/60 Amps 75/80 Amps 94/100 Amps" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Electrical table; 94/100 Amps is the GS-MPPT-100M-200V column (columns GS-MPPT-60M-200V, GS-MPPT-80M-200V, GS-MPPT-100M-200V). The two figures are the maximum input current at the maximum power point (Imp) and the short-circuit current (Isc).
Where: PDF page 150, section 8.0, Electrical table, Max. Input Current (Imp/Isc) row, GS-MPPT-100M-200V column
Printed as "Maximum Input Voltage (Voc) ALL: 200 Volts" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Electrical table, printed once for all three models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 150, section 8.0, Electrical table, Maximum Input Voltage (Voc) row
Printed as "Battery and PV input terminals 10 - 53.5 mm2 / #8 - 1/0 AWG" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), the wire size range the battery and PV input terminals accept, printed once for all three models. Section 2.1 (PDF page 20) adds: "The maximum power wire size is 1/0 AWG / 53.5 mm2 (multi-strand)." The minimum size for an installation follows the manual's ampacity rules (at least 125% of the controller's battery current rating).
Where: PDF page 151, section 8.0, Mechanical table, Wire Size Range, Battery and PV input terminals row
Printed as "GS-MPPT-100M-200V 125 Amps" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), Table 1, the recommended battery circuit breaker or fuse rating on the GS-MPPT-100M-200V row. The manual requires battery breakers or fuses sized at a minimum of 125% of the controller's continuous output current, and (PDF page 19) over-current protection interrupt ratings of at least 2kA, 3kA and 5kA for 12V, 24V and 48V systems.
Where: PDF page 27, section 2.4, Table 1 (Battery Circuit Breaker/Fuse Current Ratings)
Printed as "Battery and PV input terminals 100 in-lb / 11.3 N-m" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), a maximum torque printed as "100 in-lb / 11.3 N-m" for the battery and PV input terminals of all three models. Section 2.5.5 (PDF page 41) also gives 100 in-lb (11.3 Nm) as the maximum PV terminal torque.
Where: PDF page 151, section 8.0, Mechanical table, Maximum torque, Battery and PV input terminals row
Printed as "Maximum Self- consumption < 2.4 Watts (12/24V); < 3.2 Watts (48V)" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Electrical table, printed once for all three models. The manual states self-consumption in watts, not milliamps.
Where: PDF page 150, section 8.0, Electrical table, Maximum Self-consumption row
SD Card; USB-C for data; RS-232 Port; EIA-485 Port; Ethernet/RJ-45 Port; Controller Area Network (CAN); Bluetooth Low Power
Printed as "SD Card Yes (8 GB included) USB-C for data Yes RS-232 Port Yes EIA-485 Port Yes Ethernet/RJ-45 Port Yes Controller Area Network (CAN) Yes Bluetooth Low Power Yes" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Communication Interfaces table for "GENSTAR MPPT - all models". The manual notes on PDF page 124 that the RS-232 and EIA-485 ports share hardware and cannot be used simultaneously.
Where: PDF page 152, section 8.0, Communication Interfaces table
Printed as "1 - Sealed 14.1 13.7" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), Table 6, the eight preset battery types (presets 1 and 2 Sealed, 3 to 5 Sealed / Flooded, 6 to 8 LiFePO4); the trailing 2 is a footnote mark. The manual's caution on PDF page 90 reads "LiFePO4 settings are for 4, 8 and 16-cell LiFePO4 batteries only".
Printed as "Locate the GenStar MPPT on a vertical surface that is protected from direct sun, high temperatures, and water." in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 2.3 Mounting, Step 1, a statement for all GenStar MPPT models.
Where: PDF page 24, section 2.3 (Mounting), Step 1
Printed as "Equip. grounding terminals 50 in-lb / 5.65 N-m" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), a maximum torque printed as "50 in-lb / 5.65 N-m" for the equipment grounding terminal of all three models.
Where: PDF page 151, section 8.0, Mechanical table, Maximum torque, Equip. grounding terminals row
Printed as "Battery and PV input terminals 100 in-lb / 11.3 N-m" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), a maximum torque printed as "100 in-lb / 11.3 N-m" for the battery and PV input terminals of all three models. Section 2.5.4 (PDF page 40) also gives 100 in-lb (11.3 Nm) as the maximum battery terminal torque.
Where: PDF page 151, section 8.0, Mechanical table, Maximum torque, Battery and PV input terminals row
Printed as "Battery Voltage Range ALL: 9-72V (charging); 10-72V (load); Power OFF < 8V" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Electrical table, printed once for all three models.
Where: PDF page 150, section 8.0, Electrical table, Battery Voltage Range row
Printed as "Ambient Operating Temperature Range -30°C to +60°C (current may de-rate above 45°C)" in Morningstar's GenStar MPPT Installation, Operation and Maintenance Manual (MS-003633 v3.0), section 8.0 Environmental table, printed once for all three models. The manual adds that current may de-rate above 45°C. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 153, section 8.0, Environmental table, Ambient Operating Temperature Range row
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA 22.2 107-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109-1manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
EMC Directive 2014/30/EUmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
ICES-003manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Class Bmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CEC Australia Listingmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 60950manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
GS-MPPT-100M-200V
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Location: Cover page (MODELS list) and section 8.0 (Technical Specifications)
Retrieved Oct 1, 2026
Morningstar's own installation, operation and maintenance manual for the GenStar MPPT models GS-MPPT-60M-200V, GS-MPPT-80M-200V and GS-MPPT-100M-200V, captured 1 October 2026 from morningstarcorp.com, where the product page links it; revision MS-003633 v3.0 as printed on the back cover. Manufacturer instructions and specifications, not independent tests.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA 22.2 107-1Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109-1Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
EMC Directive 2014/30/EUManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
ICES-003Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Class BManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CEC Australia ListingManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 60950Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: MODELS table and Technical Specifications blocks
Retrieved Sep 27, 2026
Primary source for the three GenStar MPPT models.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Morningstar's own GenStar MPPT datasheet, control #MS-003676, dated May 12, 2026, from morningstarcorp.com's own GenStar MPPT product page.
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Morningstar GenStar MPPT Solar DC System Controller Installation, Operation and Maintenance Manual (MS-003633 v3.0)
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].