Charged ReviewsSaved 0Compare 0Login
RICH SOLAR
DC battery module

RICH SOLAR ALPHA 1 LITE

Key specs

Nominal voltage12.8 V
Capacity100 Ah
Weight11 kg / 24 lb converted Check note
Nominal energy1.28 kWh
Converted: 1280 Wh x 0.001 = 1.28 kWh
Cycle life3,200 cycles Check note
Continuous discharge100 A

6 specs not documented yet: cell manufacturer, cell model, usable energy, continuous charge current, continuous output power, estimated throughputHelp fill in ›

All specifications

Identity

BrandRICH SOLAR · Website Paid link
ModelALPHA 1 LITE
MarketUS
Manufacturer SKURS-B121
About brandBattery and solar equipment manufacturer.
SKU detail
conditions: Exact part/model identifier in the manufacturer specification.
Sources: [1]
FieldValueConditionsSource
Bluetoothno boolean
Date from filename, not separately printed issue date; 4 parallel maximum. Heater activates below 41F and stops above 50F on ALPHA1/PRO only.
Where: PDF p2 exact model column and common specifications
[1]
ChemistryLiFePO4Manufacturer document chemistry.[1]
TerminalsM8
Where: Datasheet p2
[1]
Weight11 kg / 24 lb converted Check note
Manual and datasheet weights differ. The ALPHA 1 LITE User Manual (240914) prints "About 24.3lb/11.0kg"; the ALPHA 1 Series datasheet (20260826) prints "Net Weight 24.0 lbs".
Printed as "Weight About 24.3lb/11.0kg, Net battery weight" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data, captured on September 26, 2026. Revised on 26 September 2026: The exact-model user manual is the primary source (owner ruling of September 26, 2026); the ALPHA 1 Series datasheet (20260826) prints "Net Weight 24.0 lbs" and stays beside it.
Where: Technical Data (PDF page 14)
Sources
10.9 kg

Date from filename, not separately printed issue date; 4 parallel maximum. Heater activates below 41F and stops above 50F on ALPHA1/PRO only.

[1]
[2]
Cell modelUnknownNo source on record
Cycle life3,200 cycles Check note
≥3200 cycles to 70% capacity, full 50A cycles
Manual and datasheet cycle ratings differ. The ALPHA 1 LITE User Manual (240914) prints "≥3200" cycles to 70% capacity retention; the ALPHA 1 Series datasheet (20260826) prints "4,000+ (80% DoD)" for RS-B121.
Printed as "Cycle life (times)(77±3.6°F) ≥3200, capacity retention: ≥70%" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data, Cycle life (PDF page 15): 50A constant-current charge to the charge voltage, 50A discharge to 11.2V, repeated until the discharge capacity reaches 70% of rated capacity, captured on September 26, 2026. Revised on 26 September 2026: The exact-model user manual is the primary source (owner ruling of September 26, 2026); the ALPHA 1 Series datasheet (20260826) prints "4,000+ (80% DoD)" for RS-B121 and stays beside it.
Where: Technical Data, Cycle life (PDF page 15)
Sources
4,000 cycles

Minimum claim at 80% DoD; C-rate, temperature and capacity-retention endpoint not specified.

[1]
[2]
Capacity100 Ah
Exact model column in the cited manufacturer document.
Where: PDF p2 exact model column and common specifications
[1]
Self heatingno boolean
Date from filename, not separately printed issue date; 4 parallel maximum. Heater activates below 41F and stops above 50F on ALPHA1/PRO only.
Where: PDF p2 exact model column and common specifications
[1]
DimensionsW 168 × H 211 × L 260 mm / W 6.61 × H 8.31 × L 10.2 in converted
Printed as "10.2x6.6x8.3in /260x168x211mm" in RICH SOLAR user manual, RICH SOLAR ALPHA 1 LITE user manual, PDF page 15 (printed page 14), Standard Parameters table, Overall dimensions row. Revised on 1 October 2026: The ALPHA 1 LITE user manual prints the overall dimensions directly in millimeters, 260 x 168 x 211 mm, so the inch conversion is replaced by the printed metric figures.
Where: RICH SOLAR ALPHA 1 LITE user manual, PDF page 15 (printed page 14), Standard Parameters table, Overall dimensions row
[2]
Terminal sizeM8
Printed as "1. Negative battery terminal(M8) 2. Positive battery terminal(M8)" in the RICH SOLAR user manual (PDF page 8, Installation, components).
Where: PDF page 8, Installation, components
[2]
Battery format
Case battery
Site classificationBased onOfficial datasheet
Details

Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.

Physical enclosure format; installation methods follow the exact manual.

Official datasheet: RICH SOLAR ALPHA series: datasheet
Enclosure ratingIP65
Where: Datasheet p2
[1]
Maximum charge100 A
Date from filename, not separately printed issue date; 4 parallel maximum. Heater activates below 41F and stops above 50F on ALPHA1/PRO only.
Where: PDF p2 exact model column and common specifications
[1]
Cell manufacturerUnknownNo source on record
Nominal voltage12.8 V
Exact model column in the cited manufacturer document.
Where: PDF p2 exact model column and common specifications
[1]
Standard charge50 A
Printed as "Nominal discharging cutoff voltage Standard charging current Maximum charging current"; "1280Wh 14.4V 11.2V 50A 100A 50A 100A 100A" in the RICH SOLAR user manual (PDF page 14, Technical Data, battery technical parameters). The table prints its row labels and values in matching order: standard charging current 50A, maximum charging current 100A.
Where: PDF page 14, Technical Data, battery technical parameters
[2]
Usable energyUnknownNo source on record
Max parallel units4 units
Printed as "A maximum of 4 batteries in parallel." in RICH SOLAR user manual, PDF page 10, Configuration warnings. Revised on 1 October 2026: The ALPHA 1 LITE User Manual prints "A maximum of 4 batteries in parallel.", a higher-ranked source than the datasheet, and the limit is a printed maximum.
Where: PDF page 10, Configuration warnings
[2]
Nominal energy1.28 kWh
Converted: 1280 Wh x 0.001 = 1.28 kWh
Printed as "Nominal energy 1280Wh" in RICH SOLAR user manual, RICH SOLAR ALPHA 1 LITE user manual, PDF page 14, Standard Parameters table, Nominal energy row. Revised on 1 October 2026: The ALPHA 1 LITE user manual prints a nominal energy of 1280 Wh, and the manual ranks above the datasheet and product page; 1.28 kWh is the same figure in kilowatt-hours.
Where: RICH SOLAR ALPHA 1 LITE user manual, PDF page 14, Standard Parameters table, Nominal energy row
Sources
Converted: 1280 Wh x 0.001 = 1.28 kWh
[2]
Continuous chargeUnknownNo source on record
Maximum discharge100 A
Printed as "Maximum discharge current 100A" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026.
Where: Technical Data, Battery Technical Parameters (PDF page 14)
[2]
Charge temperature0 to 55 °C / 32 to 131 °F converted
Charge current limit varies by temperature band
Charging temperature row printed as bands with a charge current limit for each: 30A at "32~50°F / 0~10℃", 50A at "50~68°F / 10~20℃", 100A at "68~104°F / 20~40℃" and 30A at "104~131°F / 40~55℃" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data (PDF page 15), captured on September 26, 2026.
Where: Technical Data (PDF page 15)
[2] [1]
Continuous outputUnknownNo source on record
Max charge voltage14.4 V
Printed as "Max Charge Voltage 14.4V" in the ALPHA 1 Series datasheet (20260826) and as "Nominal charging voltage 14.4V" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), captured on September 26, 2026.
Where: Datasheet Electrical Performance & Charging; manual Technical Data (PDF page 14)
[1] [2]
Mounting orientationPlace the battery smoothly with the positive and negative poles facing up.; Do not mount the battery on the wall without the mounting bracket.
Printed as "Place the battery smoothly with the positive and negative poles facing up."; "Do not mount the battery on the wall without the mounting bracket." in the RICH SOLAR user manual (PDF page 8, Installation, mounting instructions).
Where: PDF page 8, Installation, mounting instructions
[2]
Recommended charge50 A
Date from filename, not separately printed issue date; 4 parallel maximum. Heater activates below 41F and stops above 50F on ALPHA1/PRO only.
Where: PDF p2 exact model column and common specifications
[1]
Standard discharge50 A
Printed as "Standard discharge current 50A" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026.
Where: Technical Data, Battery Technical Parameters (PDF page 14)
[2]
Storage temperature-30 to 55 °C / -22 to 131 °F converted
Less than 1 month; -10 to 45 °C for more than 3 months
Printed as "Storage temperature -22~131°F / -30~55℃, 90%RH Max, Less than 1 month" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data (PDF page 15); for more than 3 months it prints "14~113°F / -10~45℃", captured on September 26, 2026.
Where: Technical Data (PDF page 15)
[2]
Continuous discharge100 A
Date from filename, not separately printed issue date; 4 parallel maximum. Heater activates below 41F and stops above 50F on ALPHA1/PRO only.
Where: PDF p2 exact model column and common specifications
[1]
Discharge temperature-20 to 60 °C / -4 to 140 °F converted
Printed as "Discharge temperature -4~140°F /-20~60℃" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data (PDF page 15), captured on September 26, 2026.
Where: Technical Data (PDF page 15)
[2]
Discharge cutoff voltage11.2 V Check note
Manual and datasheet cutoff voltages differ. The ALPHA 1 LITE User Manual (240914) prints "Nominal discharging cutoff voltage 11.2V"; the ALPHA 1 Series datasheet (20260826) prints "Discharging Cutoff Voltage 10.0V" for RS-B121.
Printed as "Nominal discharging cutoff voltage 11.2V" in the RICH SOLAR ALPHA 1 LITE User Manual (file dated 240914), Technical Data, Battery Technical Parameters (PDF page 14), captured on September 26, 2026. Revised on 26 September 2026: The exact-model user manual is the primary source (owner ruling of September 26, 2026); the ALPHA 1 Series datasheet (20260826) prints 10.0V for the RS-B121 column and is kept beside it.
Where: Technical Data, Battery Technical Parameters (PDF page 14)
Sources
10 V

Printed as "Discharging Cutoff Voltage 10.0V" in the ALPHA 1 Series datasheet (20260826), common to RS-B121, RS-B121S and RS-B121SP, captured on September 26, 2026.

[1]
[2]
Estimated lifetime energy mwhUnknown
Not printed for this model in the documents on file. Revised on 1 October 2026: RICH SOLAR prints no lifetime energy figure; the stored value was computed from the nominal energy and the rated cycle count.
Where: Technical Data (Nominal energy, Cycle life)
Sources
4.096 MWh

Our estimate from the ALPHA 1 Series datasheet (20260826), which prints "Nominal Energy 1,280Wh" and "Cycle Life 4,000+ (80% DoD)"; assumes nominal energy on every cycle and models no degradation.

[1]
[2]
Low temperature charge cutoffyes
Where: Datasheet p2
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Basic specs
1.28 kWh* (1280 Wh x 0.001 = 1.28 kWh)Discharge 100 ACharge 50 A standard
$ / rated kWh
Unavailable
Warranty
5 yearsSee terms
Lifetime production
Not published
Size
9.22 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)Value needs confirmation: Manual and datasheet weights differW: 168 × H: 211 × L: 260 mm / W: 6.61 × H: 8.31 × L: 10.2 in11 kg / 24 lb0.14 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)

Evidence score

9/10040% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

12 V · Case battery · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Warranty term5 years5 / 20

5 years · 20% weight

5 of 20 years, the best documented for a small DC battery (printed by the maker): Bioenno Power 6V 3Ah LiFePO4 Battery (PVC, BLF-0603W)

Printed as "*5-Year Warranty" under ALPHA LITE Series on RICH SOLAR's Limited Warranty page, captured on September 26, 2026; the row names the category, not a model. The asterisk is explained as "*Prorated Warranty". Revised on 26 September 2026: Re-read against the current warranty page; the earlier record was an earlier capture of the same page with a shorter note.

25 / 100 × 20 = 5 points.

[3] [4]

Lifetime / capacity3,200 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

The maker's documents disagree; the less favorable printed figure, 3,200 cycles, is scored. Warning: Manual and datasheet cycle ratings differ

[2]

Not documented, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UN 38.3manufacturer claimpresent at observation[1]
Scope
pack
Covered models
ALPHA 1 LITE
Limitations
Transport claim.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
MSDSmanufacturer claimpresent at observation[1]
Scope
pack
Covered models
ALPHA 1 LITE
Limitations
Safety data document claim, not a product safety certification.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
RemedyRICH SOLAR will, at its option, (1) repair the product at no charge, using new or refurbished replacement parts, or (2) exchange the product with a product that is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026, which adds that a replacement "assumes the remaining warranty of the original product or ninety (90) days" from replacement or repair, whichever is longer. Revised on 26 September 2026: The earlier value summarized the prorated replacement schedule, now recorded under Proration exactly as printed; the page's REMEDY paragraph is recorded here as printed.
Where: Limited Warranty page, REMEDY
[3]
TransferThis warranty is not transferable to any subsequent owner of a RICH SOLAR product.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026.
Where: Limited Warranty page, LIMITED TO ORIGINAL CONSUMER BUYER
[3]
Proration5-Year Prorated Warranty Rates Year 1: Full replacement (100% coverage) Year 2: 80% coverage (customer pays 20% of the cost) Year 3: 60% coverage (customer pays 40% of the cost) Year 4: 40% coverage (customer pays 60% of the cost) Year 5: 20% coverage (customer pays 80% of the cost)
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026. The page marks the ALPHA LITE Series term with "*" ("*Prorated Warranty") and prints this 5-year table; it does not name the table per row.
Where: Limited Warranty page, PRORATED WARRANTY
[3]
ConditionsThis warranty does not apply to (i) damage caused by accident, abuse, misuse, misapplication, or non-RICH SOLAR products; (ii) damage caused by service performed by anyone other than RICH SOLAR; (iii) a product or a part that has been modified without the written permission of RICH SOLAR; (iv) a product where any RICH SOLAR serial number has been removed or defaced, or (v) any product purchased through an online auction house. This limited warranty does not apply to any battery cell or product containing a battery cell unless the battery cell has been fully charged by you within seven (7) days after your purchase of the product and at least once every 6 months thereafter. Please note that failure to properly install or operate the battery will void the Limited Warranty.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026; applies to every RICH SOLAR product.
Where: Limited Warranty page, EXCLUSIONS AND LIMITATIONS and PRORATED WARRANTY
[3]
Start basisA sales receipt from the original consumer purchase, or other reasonable documentary proof, is required in order to establish the start of the warranty period.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026.
Where: Limited Warranty page, WARRANTY PERIOD
[3]
RegistrationWarranty coverage is not conditioned upon such registration.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026; the page adds that completing the online Product Registration Form "within thirty (30) days after purchasing your product, that registration can also establish the start date of the warranty period".
Where: Limited Warranty page, WARRANTY PERIOD
[3]
Warranty term5 years
Prorated after year 1
Printed as "*5-Year Warranty" under ALPHA LITE Series on RICH SOLAR's Limited Warranty page, captured on September 26, 2026; the row names the category, not a model. The asterisk is explained as "*Prorated Warranty". Revised on 26 September 2026: Re-read against the current warranty page; the earlier record was an earlier capture of the same page with a shorter note.
Where: Limited Warranty page, WARRANTY PERIOD, ALPHA LITE Series
[3] [4]
Labor and shippingYou must then send the product by mail or courier, with shipping costs paid by you ... We will process your return and send your repaired or replacement product to you at our expense for the product being shipped to locations in North America.
Printed on RICH SOLAR's Limited Warranty page, captured on September 26, 2026. Return shipping at RICH SOLAR's expense is stated only for North America.
Where: Limited Warranty page, warranty service paragraph
[3]
Warranted throughputUnknownNo source on record

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • RICH SOLAR user manualOfficial · RICH SOLAR · Official user manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Exact source product model shown on manufacturer manual cover; historical revision may differ from current hardware.

    Retrieved Sep 15, 2026

    SHA-256: 0fb2fe321c95e73e23ba57c38f697c40f2d4c1fafb51e0b34299c931c077838b

    Archived copies

    Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 5.75 MB

    Archived copy, unaltered, kept as a record of what RICH SOLAR published. Original address: https://cdn.shopify.com/s/files/1/0058/2769/0553/files/ALPHA_1_LITE_Manual_240914.pdf?v=1726812608. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    18

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 0fb2fe321c95e73e23ba57c38f697c40f2d4c1fafb51e0b34299c931c077838b

    Open
  • Datasheets

  • RICH SOLAR ALPHA series: datasheetOfficial · RICH SOLAR · Official datasheet · PDF
    Certificate & compliance claims (2)
    UN 38.3Manufacturer claim · packClaimedListed when checked

    Transport claim.

    Manufacturer document

    Official datasheet: RICH SOLAR ALPHA series: datasheet
    MSDSManufacturer claim · packClaimedListed when checked

    Safety data document claim, not a product safety certification.

    Manufacturer document

    Official datasheet: RICH SOLAR ALPHA series: datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Filename includes 20260826. No printed revision identifier or issue date established; copyright 2026 is not a revision date.

    Location: PDF p2 exact model column and common specifications

    Retrieved Sep 9, 2026

    SHA-256: a7d3ffcef138dbc44ac39fd3c35b4700d22cb6db56e67daf6c779af3da688ee8

    Archived copies

    Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.25 MB

    Archived copy, unaltered, kept as a record of what RICH SOLAR published. Original address: https://cdn.shopify.com/s/files/1/0058/2769/0553/files/ALPHA_1_SERIES_20260826.pdf?v=1787712023. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: a7d3ffcef138dbc44ac39fd3c35b4700d22cb6db56e67daf6c779af3da688ee8

    Open
  • Warranty

  • RICH SOLAR: warranty Paid linkOfficial · RICH SOLAR · Official warranty · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Batteries and Prorated Warranty sections

    Retrieved Sep 9, 2026

    SHA-256: b3024f0f2ec179bdf9932eb4fa379f2708add696232ff1132757d8d92b7943d6

    Open Paid link

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • RICH SOLAR Limited Warranty Paid linkOfficial · RICH SOLAR · Official warranty · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: WARRANTY PERIOD, PRORATED WARRANTY, REMEDY and EXCLUSIONS AND LIMITATIONS

    Retrieved Sep 25, 2026

    RICH SOLAR's own Limited Warranty page, captured on September 26, 2026. Its WARRANTY PERIOD list gives terms by product category or series, not by stock keeping unit, and marks prorated terms with an asterisk. The manufacturer's published policy, not a certificate.

    Open Paid link

Archived documents

RICH SOLAR ALPHA series: datasheet

Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.25 MB

Archived copy, unaltered, kept as a record of what RICH SOLAR published. Original address: https://cdn.shopify.com/s/files/1/0058/2769/0553/files/ALPHA_1_SERIES_20260826.pdf?v=1787712023. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: a7d3ffcef138dbc44ac39fd3c35b4700d22cb6db56e67daf6c779af3da688ee8

RICH SOLAR user manual

Archived copy of a document published by RICH SOLAR. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 5.75 MB

Archived copy, unaltered, kept as a record of what RICH SOLAR published. Original address: https://cdn.shopify.com/s/files/1/0058/2769/0553/files/ALPHA_1_LITE_Manual_240914.pdf?v=1726812608. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
18

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 0fb2fe321c95e73e23ba57c38f697c40f2d4c1fafb51e0b34299c931c077838b

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
ALPHA 1 LITE

Manufacturer SKU RS-B121 · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: UN 38.3 · MSDS
shown detail: Not scored
state: missing
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: 5
unit: years
shown: 5 years
shown detail: Unknown
state: documented
points: 5
ceiling: 20
weight: 20
share: 25
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [3] [4]
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 3,200 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: documents-disagree
reason text: The maker's documents disagree; the less favorable printed figure, 3,200 cycles, is scored. Warning: Manual and datasheet cycle ratings differ
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [2]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. RICH SOLAR ALPHA series: datasheet (RICH SOLAR · manufacturer · observed Sep 9, 2026)
  2. RICH SOLAR user manual (RICH SOLAR · manufacturer · observed Sep 15, 2026)
  3. RICH SOLAR Limited Warranty Paid link (RICH SOLAR · manufacturer · observed Sep 25, 2026)
  4. RICH SOLAR: warranty Paid link (RICH SOLAR · manufacturer · observed Sep 9, 2026)

Sign in to report an error on this page

Similar products

All with a price

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

* Missing details