Key specs

Units
Chemistry
Cylindrical - LiFePO4
Official product page
Sources

RELiON publishes "Cylindrical - LiFePO4" against "Cell Type - Chemistry" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Mechanical Specifications, row "Cell Type - Chemistry"

Documented

Nominal energy
1.02 kWh
Official product page
Sources

RELiON publishes "1024 Wh" against "Energy" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Electrical Specifications, row "Energy"

Documented

Nominal voltage
12.8 V
Official product page
Sources

RELiON publishes "12.8 V" against "Nominal Voltage" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Electrical Specifications, row "Nominal Voltage"

Documented

Rated capacity
80 Ah
Official product page
Sources

RELiON publishes "80 Ah" against "Nominal Capacity" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Electrical Specifications, row "Nominal Capacity"

Documented

Continuous discharge current
80 A
Official datasheet
Sources

RELiON prints "Maximum Continous Discharge Current 80 A" on its RB80 data sheet (dated 05.09.23), PDF page 1.

Official datasheet: RELiON RB80 data sheet (dated 05.09.23) Rev 05.09.23 · Checked · Earlier document

Location: Data sheet PDF page 1, "Maximum Continuous Discharge Current" row (printed with the spelling "Continous")

Documented

Continuous charge current
80 A
Official datasheet
Sources

RELiON prints "Maximum Continuous Charge Current 80 A" on its RB80 data sheet (dated 05.09.23), PDF page 1.

Official datasheet: RELiON RB80 data sheet (dated 05.09.23) Rev 05.09.23 · Checked · Earlier document

Location: Data sheet PDF page 1, "Maximum Continuous Charge Current" row

Documented

Maximum discharge current
80 A
Official product page
Sources

RELiON publishes "80 A" against "Maximum Continuous Discharge Current" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Discharge Specifications, row "Maximum Continuous Discharge Current"

Documented

Maximum charge current
80 A
Official product page
Sources

RELiON publishes "80 A" against "Maximum Continuous Charge Current" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, specification table, row "Maximum Continuous Charge Current"

Documented

1 spec not documented yet: usable energyHelp fill in ›

All specs29
Chemistry
Cylindrical - LiFePO4
Official product page
Sources

RELiON publishes "Cylindrical - LiFePO4" against "Cell Type - Chemistry" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Mechanical Specifications, row "Cell Type - Chemistry"

Documented

Nominal energy
1.02 kWh
Official product page
Sources

RELiON publishes "1024 Wh" against "Energy" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Electrical Specifications, row "Energy"

Documented

Usable energy
Not documented
Nominal voltage
12.8 V
Official product page
Sources

RELiON publishes "12.8 V" against "Nominal Voltage" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Electrical Specifications, row "Nominal Voltage"

Documented

Rated capacity
80 Ah
Official product page
Sources

RELiON publishes "80 Ah" against "Nominal Capacity" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Electrical Specifications, row "Nominal Capacity"

Documented

Continuous discharge current
80 A
Official datasheet
Sources

RELiON prints "Maximum Continous Discharge Current 80 A" on its RB80 data sheet (dated 05.09.23), PDF page 1.

Official datasheet: RELiON RB80 data sheet (dated 05.09.23) Rev 05.09.23 · Checked · Earlier document

Location: Data sheet PDF page 1, "Maximum Continuous Discharge Current" row (printed with the spelling "Continous")

Documented

Continuous charge current
80 A
Official datasheet
Sources

RELiON prints "Maximum Continuous Charge Current 80 A" on its RB80 data sheet (dated 05.09.23), PDF page 1.

Official datasheet: RELiON RB80 data sheet (dated 05.09.23) Rev 05.09.23 · Checked · Earlier document

Location: Data sheet PDF page 1, "Maximum Continuous Charge Current" row

Documented

Maximum discharge current
80 A
Official product page
Sources

RELiON publishes "80 A" against "Maximum Continuous Discharge Current" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Discharge Specifications, row "Maximum Continuous Discharge Current"

Documented

Maximum charge current
80 A
Official product page
Sources

RELiON publishes "80 A" against "Maximum Continuous Charge Current" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, specification table, row "Maximum Continuous Charge Current"

Documented

Peak discharge current
160 A
Official product page
Sources

RELiON publishes "160 A (7.5±2.5 sec)" against "Peak Discharge Current" for RB80.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Location: Specifications panel, Discharge Specifications, row "Peak Discharge Current"

Documented

Charge cutoff voltage
15.6 V
Official datasheet
Sources

RELiON prints "BMS Charge Voltage Cut-Off 15.6 V (3.9 ±0.025 vpc)" on its RB80 data sheet (dated 05.09.23), PDF page 1. The printed tolerance and cell-level figure are quoted; only the pack voltage is recorded.

Official datasheet: RELiON RB80 data sheet (dated 05.09.23) Rev 05.09.23 · Checked · Earlier document

Location: Data sheet PDF page 1, "Charge Voltage Cut-Off" row

Documented

Discharge cutoff voltage
8 V
Official datasheet
Sources

RELiON prints "Discharge Under-Voltage Protection 8.0 V (2.0 ±0.08 vpc) (144 ms±30 ms)" on its RB80 data sheet (dated 05.09.23), PDF page 1. The printed tolerance and delay are quoted; only the pack voltage is recorded.

Official datasheet: RELiON RB80 data sheet (dated 05.09.23) Rev 05.09.23 · Checked · Earlier document

Location: Data sheet PDF page 1, "Discharge Under-Voltage Protection" row

Documented

Lifetime production

Not published

Published claims and calculations are not independently tested lifetime output.

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    RELiON RB80 data sheet (dated 05.09.23)OfficialRELiON BatteriesOfficial datasheet
    Source details
    Revision
    05.09.23
    Revision date
    Not stated

    File RELiON-Data-Sheet_RB80.pdf, 2 pages, captured on September 29, 2026 from RELiON's document host. It prints the model RB80 in its header and footer.

    Location: RELiON-Data-Sheet_RB80.pdf

    Retrieved

    RELiON's own two-page data sheet for the RB80, dated 05.09.23 in its footer, served from RELiON's document host and captured on September 29, 2026. It establishes the figures RELiON prints for the RB80 only. Manufacturer claims, not independent tests. Its second page is a performance chart page whose leftover template text names the RB10-PC; no figure is read from that page.

    Archived copies

    Archived copy of a document published by RELiON Batteries. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.66 MB

    Archived copy, unaltered, kept as a record of what RELiON Batteries published. Original address: https://relion-battery.s3.us-east-1.amazonaws.com/docs/product/RELiON-Data-Sheet_RB80.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e4e88b90b8ff87eee037558193b515b58702c0f54c42cb0e3a898147b063a217

    Open
  • WEB
    RELiON RB80 product identityOfficialRELiONOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Revision date not established.

    Location: Original source record

    Retrieved

    Official product page: RELiON RB80 product identity Checked
    Open

Archive and older revisions

Archive and older revisions2

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • PDF
    RELiON datasheet linked from the RB80 specifications panelOfficialRELiON BatteriesOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Linked from https://www.relionbattery.com/products/lithium/rb80 inside the Specifications panel.

    Location: RELiON-Data-Sheet_RB80-8162023.pdf

    Retrieved

    Original manufacturer PDF preserved byte for byte, downloaded through the same browser context from the link RELiON publishes inside the RB80 specifications panel. The revision is whatever was published at this URL on the access date; no later revision was checked and no coverage beyond the model page that linked it is claimed.

    SHA-256: 36022e4bcb81aa73be16d4c72cbd6b85409a3718b8aa153042f57007e592ba01

    Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document
    Archived copies

    Archived copy of a document published by RELiON Batteries. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.77 MB

    Archived copy, unaltered, kept as a record of what RELiON Batteries published. Original address: https://relion-battery.s3.us-east-1.amazonaws.com/docs/product/RELiON-Data-Sheet_RB80-8162023.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 36022e4bcb81aa73be16d4c72cbd6b85409a3718b8aa153042f57007e592ba01

    Open
  • WEB
    RELiON product page for RB80 (Specifications panel)OfficialRELiON BatteriesOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured with playwright_chromium_rendered_dom_specifications_tab_opened.

    Location: Specifications panel, 42 published rows

    Retrieved

    Manufacturer-operated product page for RB80, captured as rendered DOM with Playwright chromium because relionbattery.com answers a plain HTTPS GET with HTTP 403 and renders this table only after its Specifications tab is opened. It establishes what RELiON published on that page on the access date: the standards it names remain manufacturer statements, no issuer record was read, and no value here was taken from any other model's page.

    Open

Archived documents

RELiON datasheet linked from the RB80 specifications panel

Archived copy of a document published by RELiON Batteries. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.77 MB

Archived copy, unaltered, kept as a record of what RELiON Batteries published. Original address: https://relion-battery.s3.us-east-1.amazonaws.com/docs/product/RELiON-Data-Sheet_RB80-8162023.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 36022e4bcb81aa73be16d4c72cbd6b85409a3718b8aa153042f57007e592ba01

RELiON RB80 data sheet (dated 05.09.23)

Archived copy of a document published by RELiON Batteries. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.66 MB

Archived copy, unaltered, kept as a record of what RELiON Batteries published. Original address: https://relion-battery.s3.us-east-1.amazonaws.com/docs/product/RELiON-Data-Sheet_RB80.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e4e88b90b8ff87eee037558193b515b58702c0f54c42cb0e3a898147b063a217

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.

12 V · Case battery · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Lifetime / capacityResearch pending0 / 20

No qualifying figure · 20% weight

Not published. No lifetime-production bonus.

Not documented. Undisclosed data scores 0.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

3 on file3 claims on file · issuer check pending
UN 38.3Battery pack claim; verification pendingClaimedStatus unconfirmed

RELiON's own page for RB80 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked.

Models: RB80

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document
UL 1642Cell / component onlyClaimedStatus unconfirmed

RELiON's own page for RB80 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.

Models: RB80

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document
IEC 62133Cell / component onlyClaimedStatus unconfirmed

RELiON's own page for RB80 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.

Models: RB80

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
RB80
Observed

UN 38.3: claimed

Battery pack claim; verification pending. RELiON's own page for RB80 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document
Observed

UL 1642: claimed

Cell / component only. RELiON's own page for RB80 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document
Observed

IEC 62133: claimed

Cell / component only. RELiON's own page for RB80 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.

Official product page: RELiON product page for RB80 (Specifications panel) Checked · Earlier document

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.