Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: RELiON RB35, the product figure at the top of RELiON's own RB35 data sheet, whose page heading prints RB35; the label on the battery in the figure prints RB35. Shown against the data sheet's colored header bands, with no added text or badge. Figure from the manufacturer's document, page 1.DC battery module
RELiON RB35
Key specs
1 spec not documented yet: usable energyHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Chemistry | Cylindrical - LiFePO4 | RELiON publishes "Cylindrical - LiFePO4" against "Cell Type - Chemistry" on its own RB35 product page. Where: Specifications panel, row "Cell Type - Chemistry" | [1] |
| IP rating | IP66 | RELiON publishes "IP66" against "Enclosure Protection" on its own RB35 product page. Where: Specifications panel, row "Enclosure Protection" | [1] |
| Terminals | M8 x 1.25 | RELiON publishes "M8 x 1.25" against "Terminal Type" on its own RB35 product page. Where: Specifications panel, row "Terminal Type" | [1] |
| Weight | 4.5 kg / 9.9 lb converted | RELiON publishes "9.9 lbs (4.5 kg)" against "Weight" on its own RB35 product page. Where: Specifications panel, row "Weight" | [1] |
| Capacity | 35 Ah | RELiON publishes "35 Ah" against "Nominal Capacity" on its own RB35 product page. Where: Specifications panel, row "Nominal Capacity" | [1] |
| Dimensions | W 195 × H 171 × D 131 mm / W 7.68 × H 6.73 × D 5.16 in converted | RELiON publishes "7.8 x 5.2 x 6.7” (195 x 131 x 171 mm)" against "Dimensions (L x W x H)" on its own RB35 product page. The millimetre figures are recorded as length x width x height. Where: Specifications panel, row "Dimensions (L x W x H)" | [1] |
| Battery format | Case battery DetailsCharged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim. RELiON’s RB35 panel publishes case dimensions, a case material and threaded or tab terminal hardware and names no rack or stack mounting, so the pack is recorded as a cased battery. Official product page: RELiON product page for RB35 (Specifications panel)Location: Specifications panel, Mechanical Specifications | ||
| Max series units | 3 | RELiON publishes "3" against "Maximum Batteries Connected in Series" on its own RB35 product page. Where: Specifications panel, row "Maximum Batteries Connected in Series" | [1] |
| Maximum charge | 35 A | RELiON publishes "35 A" against "Maximum Continuous Charge Current" on its own RB35 product page. Where: Specifications panel, row "Maximum Continuous Charge Current" | [1] |
| Peak discharge | 70 A | RELiON publishes "70 A (7.5 s ±2.5 s)" against "Peak Discharge Current" on its own RB35 product page. Where: Specifications panel, row "Peak Discharge Current" | [1] |
| Nominal voltage | 12.8 V | RELiON publishes "12.8 V" against "Nominal Voltage" on its own RB35 product page. Where: Specifications panel, row "Nominal Voltage" | [1] |
| Nominal energy | 0.448 kWh | RELiON publishes "448 Wh" against "Energy" on its own RB35 product page. Where: Specifications panel, row "Energy" | [1] |
| Terminal torque | 80 to 100 in-lb | Printed as "Terminal Torque 80 - 100 in-lbs (9 - 11 N-m)" in RELiON's document "RELiON RB35 data sheet" (PDF page 1), for the battery's main terminals. Where: PDF page 1 | [2] |
| Maximum discharge | 35 A | RELiON publishes "35 A" against "Maximum Continuous Discharge Current" on its own RB35 product page. Where: Specifications panel, row "Maximum Continuous Discharge Current" | [1] |
| Charge temperature | -20 to 45 °C / -4 to 113 °F converted | RELiON publishes "-4 to 113 ºF (-20 to 45 ºC)" against "Charge Temperature*" on its own RB35 product page. Where: Specifications panel, row "Charge Temperature*" | [1] |
| Storage temperature | -5 to 35 °C / 23 to 95 °F converted | RELiON publishes "23 to 95 ºF (-5 to 35 ºC)" against "Recommended Storage Temperature" on its own RB35 product page. Where: Specifications panel, row "Recommended Storage Temperature" | [1] |
| Discharge temperature | -20 to 60 °C / -4 to 140 °F converted | RELiON publishes "-4 to 140 ºF (-20 to 60 ºC)" against "Discharge Temperature" on its own RB35 product page. Where: Specifications panel, row "Discharge Temperature" | [1] |
| Round trip efficiency | 99 % | RELiON publishes "99%" against "Efficiency" on its own RB35 product page. Where: Specifications panel, row "Efficiency" | [1] |
| Discharge cutoff voltage | 8 V | RELiON publishes "8.0 V (2.0 ±0.08 vpc) (140 ±60 ms)" against "Discharge Under-Voltage Protection" on its own RB35 product page. Where: Specifications panel, row "Discharge Under-Voltage Protection" | [1] |
| Recommended charge range | 1.75 A - 17.5 A A | RELiON publishes "1.75 A - 17.5 A" against "Recommended Charge Current" on its own RB35 product page. Where: Specifications panel, row "Recommended Charge Current" | [1] |
| Recommended charge voltage | 14.2 V - 14.6 V V | RELiON publishes "14.2 V - 14.6 V" against "Recommended Charge Voltage" on its own RB35 product page. Where: Specifications panel, row "Recommended Charge Voltage" | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Basic specs
- 0.45 kWhDischarge 35 A max.Charge 35 A max.Peak current: 70 A
- $ / rated kWh
- Unavailable
- Warranty
- UnknownSee terms
- Lifetime production
- Not published
- Size
- 4.37 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 195 × H: 171 × D: 131 mm / W: 7.68 × H: 6.73 × D: 5.16 in4.5 kg / 9.9 lb0.1 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
12 V · Case battery · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity0 / 20
No qualifying figure · 20% weight
Not published. No lifetime-production bonus.
Not documented. Undisclosed data scores 0.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
UL 1642manufacturer claimunknown[1]
- Scope
- cell
- Covered models
- RB35
- Limitations
- RELiON records UL 1642 against the CELLS used in RB35, not against the assembled pack: its Certifications row reads "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)". No certificate, issuer listing, cell model or validity was checked, and this must not be presented as a pack-level listing.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 19, 2026
- Source
- [1]
UN 38.3manufacturer claimunknown[1]
- Scope
- battery pack scope unverified
- Covered models
- RB35
- Limitations
- RELiON’s own page for RB35 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model string: no issuer listing, certificate number, edition, scope or validity was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 19, 2026
- Source
- [1]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Datasheets
- RELiON RB35 data sheetOpen
Source details
Linked from the RB35 specifications panel.
Location: RELiON-Data-Sheet_RB35.pdf
Retrieved Sep 19, 2026
RELiON publishes this specifications panel for the exact model named on the page. It establishes the printed figures for that model only; cell manufacturer, cell model, cycle life and warranty terms are not published there.
SHA-256: f0cd5593704e41db3cf22a07b1541eeda45055dff03426cb2676fc20b344f763
Other documents
- RELiON product page for RB35 (Specifications panel)Open
Source details
Location: rb35
Retrieved Sep 19, 2026
RELiON publishes this specifications panel for the exact model named on the page. It establishes the printed figures for that model only; cell manufacturer, cell model, cycle life and warranty terms are not published there.
SHA-256: bf90d7f17200490fa683d0b0e61ae06519db9c5afeaa47fdb86f1d1d3e44279b
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- RB35
Manufacturer SKU RB35
Observed Sep 19, 2026
UN 38.3: claimed
Battery pack claim; verification pending. RELiON’s own page for RB35 lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model string: no issuer listing, certificate number, edition, scope or validity was checked.
Observed Sep 19, 2026
UL 1642: claimed
Cell / component only. RELiON records UL 1642 against the CELLS used in RB35, not against the assembled pack: its Certifications row reads "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)". No certificate, issuer listing, cell model or validity was checked, and this must not be presented as a pack-level listing.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: 0.21-personal documented pct: 0 basis: nominal missing: Certificates evidence needed Warranty term needed Warranty energy disclosure evidence needed Lifetime / capacity evidence needed Cell model disclosure evidence needed criteria: key: certificateEvidence label: Certificates value: 0 unit: evidence points shown: UN 38.3 · UL 1642 shown detail: Research pending state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules. display note: Unknown Sources: No source on record key: years label: Warranty term value: Unknown unit: years shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: throughputEvidence label: Warranty energy disclosure value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment. display note: Unknown Sources: No source on record key: lifetime label: Lifetime / capacity value: Unknown unit: MWh/kWh shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: no reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not published. No lifetime-production bonus. display note: Unknown Sources: [1] key: cellDisclosure label: Cell model disclosure value: 0 unit: disclosure points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 5 weight: 5 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- RELiON product page for RB35 (Specifications panel) (RELiON Batteries · manufacturer · observed Sep 19, 2026)
- RELiON RB35 data sheet (RELiON Batteries · manufacturer · observed Sep 19, 2026)
Sign in to report an error on this page
Similar products
All with a priceBigBattery FEAGL-24016-G2-NC
BigBattery FEAGL-36015-G2
BigBattery FEAGL-48016-G2