Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: RELiON RB100-DHP, the product figure at the top of RELiON's own RB100-DHP data sheet, whose page heading prints RB100-DHP; the label on the battery in the figure prints RB100-DHP. Shown against the data sheet's colored header bands, with no added text or badge. Figure from the manufacturer's document, page 1.DC battery module
RELiON RB100-DHP
Key specs
1 spec not documented yet: usable energyHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Chemistry | Cylindrical LiFePO4 | RELiON publishes "Cylindrical LiFePO4" against "Cell Type - Chemistry" on its own RB100-DHP product page. Where: Specifications panel, row "Cell Type - Chemistry" | [1] |
| IP rating | IP66 | RELiON publishes "IP66" against "Enclosure Protection" on its own RB100-DHP product page. Where: Specifications panel, row "Enclosure Protection" | [1] |
| Terminals | M8 x 1.25 | RELiON publishes "M8 x 1.25" against "Terminal Type" on its own RB100-DHP product page. Where: Specifications panel, row "Terminal Type" | [1] |
| Weight | 13.7 kg / 30.2 lb converted | RELiON publishes "30.2 lbs (13.7 kg)" against "Weight" on its own RB100-DHP product page. Where: Specifications panel, row "Weight" | [1] |
| Capacity | 100 Ah | RELiON publishes "100 Ah" against "Nominal Capacity" on its own RB100-DHP product page. Where: Specifications panel, row "Nominal Capacity" | [1] |
| Case material | ABS | RELiON prints "Case Material ABS" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. Where: Data sheet PDF page 1, "Case Material" row | [2] |
| Dimensions | W 335 × H 191 × D 174 mm / W 13.2 × H 7.52 × D 6.85 in converted | RELiON publishes "13.2 x 6.9 x 7.5" 335 x 174 x 191 mm" against "Dimensions (L x W x H)" on its own RB100-DHP product page. The millimetre figures are recorded as length x width x height. Where: Specifications panel, row "Dimensions (L x W x H)" | [1] |
| Battery format | Case battery DetailsCharged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim. RELiON’s RB100-DHP panel publishes case dimensions, a case material and threaded or tab terminal hardware and names no rack or stack mounting, so the pack is recorded as a cased battery. Official product page: RELiON product page for RB100-DHP (Specifications panel)Location: Specifications panel, Mechanical Specifications | ||
| Enclosure rating | IP66 | RELiON prints "Enclosure Protection IP66" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. Where: Data sheet PDF page 1, "Enclosure Protection" row | [2] |
| Max series units | 1 | RELiON publishes "1 (Single Use)" against "Maximum Batteries Connected in Series" on its own RB100-DHP product page. Where: Specifications panel, row "Maximum Batteries Connected in Series" | [1] |
| Maximum charge | 100 A | RELiON publishes "100 A" against "Maximum Continuous Charge Current" on its own RB100-DHP product page. Where: Specifications panel, row "Maximum Continuous Charge Current" | [1] |
| Peak discharge | 800 A | RELiON publishes "800 A (2 s)" against "Peak Discharge Current" on its own RB100-DHP product page. Where: Specifications panel, row "Peak Discharge Current" | [1] |
| Nominal voltage | 12.8 V | RELiON publishes "12.8 V" against "Nominal Voltage" on its own RB100-DHP product page. Where: Specifications panel, row "Nominal Voltage" | [1] |
| Nominal energy | 1.28 kWh | RELiON publishes "1280 Wh" against "Energy" on its own RB100-DHP product page. Where: Specifications panel, row "Energy" | [1] |
| Terminal torque | 9 to 11 N·m | RELiON prints "Terminal Torque 80 - 100 in-lbs (9 - 11 N-m)" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. The data sheet prints the torque in inch-pounds and in N-m; the N-m range is recorded as printed. Where: Data sheet PDF page 1, "Terminal Torque" row | [2] |
| Continuous charge | 100 A | RELiON prints "Maximum Continuous Charge Current 100 A" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. Where: Data sheet PDF page 1, "Maximum Continuous Charge Current" row | [2] |
| Maximum discharge | 100 A | RELiON publishes "100 A" against "Maximum Continuous Discharge Current" on its own RB100-DHP product page. Where: Specifications panel, row "Maximum Continuous Discharge Current" | [1] |
| Charge temperature | -20 to 45 °C / -4 to 113 °F converted | RELiON publishes "-4 to 113 ºF (-20 to 45 ºC)" against "Charge Temperature*" on its own RB100-DHP product page. Where: Specifications panel, row "Charge Temperature*" | [1] |
| Storage temperature | -5 to 35 °C / 23 to 95 °F converted | RELiON publishes "23 to 95 ºF (-5 to 35 ºC)" against "Recommended Storage Temperature" on its own RB100-DHP product page. Where: Specifications panel, row "Recommended Storage Temperature" | [1] |
| Continuous discharge | 100 A | RELiON prints "Maximum Continous Discharge Current 100 A" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. Where: Data sheet PDF page 1, "Maximum Continuous Discharge Current" row (printed with the spelling "Continous") | [2] |
| Charge cutoff voltage | 15.4 V | RELiON prints "BMS Charge Voltage Cut-Off 15.4 V (3.85 ±0.025 vpc)" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. The printed tolerance and cell-level figure are quoted; only the pack voltage is recorded. Where: Data sheet PDF page 1, "Charge Voltage Cut-Off" row | [2] |
| Discharge temperature | -20 to 60 °C / -4 to 140 °F converted | RELiON publishes "-4 to 140 ºF (-20 to 60 ºC)" against "Discharge Temperature" on its own RB100-DHP product page. Where: Specifications panel, row "Discharge Temperature" | [1] |
| Other compliance claims | UN38.3, UKCA & CE (battery) UL1642 & IEC62133 (cells) | RELiON prints "Certifications UN38.3, UKCA & CE (battery) UL1642 & IEC62133 (cells)" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. Marks and standards RELiON lists on its own data sheet, recorded as printed; no certificate or issuer record was read. Where: Data sheet PDF page 1, "Certifications" row | [2] |
| Internal resistance | 30 mΩ | RELiON prints "Resistance ≤30 mΩ @ 50% SOC" on its RB100-DHP data sheet (dated 05.22.23), PDF page 1. Printed as a battery (pack) resistance, with the bound "≤" and the condition "@ 50% SOC" as quoted. Where: Data sheet PDF page 1, "Resistance" row | [2] |
| Round trip efficiency | 99 % | RELiON publishes "99%" against "Efficiency" on its own RB100-DHP product page. Where: Specifications panel, row "Efficiency" | [1] |
| Discharge cutoff voltage | 9.2 V | RELiON publishes "9.2 V (2.3 ±0.08 vpc) (4.2 ±0.5 s)" against "Discharge Under-Voltage Protection" on its own RB100-DHP product page. Where: Specifications panel, row "Discharge Under-Voltage Protection" | [1] |
| Recommended charge range | 5 A - 50 A A | RELiON publishes "5 A - 50 A" against "Recommended Charge Current" on its own RB100-DHP product page. Where: Specifications panel, row "Recommended Charge Current" | [1] |
| Recommended charge voltage | 14.2 V - 14.6 V V | RELiON publishes "14.2 V - 14.6 V" against "Recommended Charge Voltage" on its own RB100-DHP product page. Where: Specifications panel, row "Recommended Charge Voltage" | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Basic specs
- 1.28 kWhDischarge 100 ACharge 100 APeak current: 800 A
- $ / rated kWh
- Unavailable
- Warranty
- UnknownSee terms
- Lifetime production
- Not published
- Size
- 11.13 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 335 × H: 191 × D: 174 mm / W: 13.2 × H: 7.52 × D: 6.85 in13.7 kg / 30.2 lb0.11 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
12 V · Case battery · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity0 / 20
No qualifying figure · 20% weight
Not published. No lifetime-production bonus.
Not documented. Undisclosed data scores 0.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
UL 1642manufacturer claimunknown[1]
- Scope
- cell
- Covered models
- RB100-DHP
- Limitations
- RELiON records UL 1642 against the CELLS used in RB100-DHP, not against the assembled pack: its Certifications row reads "UKCA & CE (battery); UN38.3 (battery); UL1642 & IEC62133 (cells)". No certificate, issuer listing, cell model or validity was checked, and this must not be presented as a pack-level listing.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 19, 2026
- Source
- [1]
UN 38.3manufacturer claimunknown[1]
- Scope
- battery pack scope unverified
- Covered models
- RB100-DHP
- Limitations
- RELiON’s own page for RB100-DHP lists "UKCA & CE (battery); UN38.3 (battery); UL1642 & IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model string: no issuer listing, certificate number, edition, scope or validity was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 19, 2026
- Source
- [1]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Datasheets
- RELiON RB100-DHP data sheetOpen
Source details
Linked from the RB100-DHP specifications panel.
Location: RELiON-Data-Sheet_RB100-DHP.pdf
Retrieved Sep 19, 2026
RELiON publishes this specifications panel for the exact model named on the page. It establishes the printed figures for that model only; cell manufacturer, cell model, cycle life and warranty terms are not published there.
SHA-256: 339993e584aa1c8dc39249ea90cd87a4595072f2426bc44e624099f25a25699c
Other documents
- RELiON product page for RB100-DHP (Specifications panel)Open
Source details
Location: rb100-dhp
Retrieved Sep 19, 2026
RELiON publishes this specifications panel for the exact model named on the page. It establishes the printed figures for that model only; cell manufacturer, cell model, cycle life and warranty terms are not published there.
SHA-256: 50cbf548e0f3f349448122a9be4998be696338957723dda088bd29d8ac400e5a
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- RB100-DHP
Manufacturer SKU RB100-DHP
Observed Sep 19, 2026
UN 38.3: claimed
Battery pack claim; verification pending. RELiON’s own page for RB100-DHP lists "UKCA & CE (battery); UN38.3 (battery); UL1642 & IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model string: no issuer listing, certificate number, edition, scope or validity was checked.
Observed Sep 19, 2026
UL 1642: claimed
Cell / component only. RELiON records UL 1642 against the CELLS used in RB100-DHP, not against the assembled pack: its Certifications row reads "UKCA & CE (battery); UN38.3 (battery); UL1642 & IEC62133 (cells)". No certificate, issuer listing, cell model or validity was checked, and this must not be presented as a pack-level listing.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: 0.21-personal documented pct: 0 basis: nominal missing: Certificates evidence needed Warranty term needed Warranty energy disclosure evidence needed Lifetime / capacity evidence needed Cell model disclosure evidence needed criteria: key: certificateEvidence label: Certificates value: 0 unit: evidence points shown: UN 38.3 · UL 1642 shown detail: Research pending state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules. display note: Unknown Sources: No source on record key: years label: Warranty term value: Unknown unit: years shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: throughputEvidence label: Warranty energy disclosure value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment. display note: Unknown Sources: No source on record key: lifetime label: Lifetime / capacity value: Unknown unit: MWh/kWh shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: no reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not published. No lifetime-production bonus. display note: Unknown Sources: [1] key: cellDisclosure label: Cell model disclosure value: 0 unit: disclosure points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 5 weight: 5 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- RELiON product page for RB100-DHP (Specifications panel) (RELiON Batteries · manufacturer · observed Sep 19, 2026)
- RELiON RB100-DHP data sheet (RELiON Batteries · manufacturer · observed Sep 19, 2026)
Sign in to report an error on this page
Similar products
All with a priceBigBattery FEAGL-24016-G2-NC
BigBattery FEAGL-36015-G2
BigBattery FEAGL-48016-G2
* Missing details