Charged ReviewsSaved 0Compare 0Login
RELiON RB100-D 12V 100Ah Battery
RELiON
DC battery module

RELiON RB100-D 12V 100Ah Battery

Key specs

Nominal voltage12.8 V
Capacity100 Ah
Weight13.7 kg / 30.2 lb converted
Nominal energy1.28 kWh
Continuous discharge100 A
Maximum charge100 A

1 spec not documented yet: usable energyHelp fill in ›

All specifications

Identity

BrandRELiON · Website
ModelRB100-D
MarketUS
Manufacturer SKURB100-D
SKU detail
locator: RELiON RB100-D data sheet, PDF page 1
conditions: The manufacturer's document "RELiON RB100-D data sheet" prints RB100-D on PDF page 1.
Sources: [1]
FieldValueConditionsSource
ChemistryCylindrical LiFePO4Manufacturer data sheet.[1]
TerminalsM8 x 1.25
RELiON publishes "M8 x 1.25" against "Terminal Type" for RB100-D.
Where: Specifications panel, Mechanical Specifications, row "Terminal Type"
[2]
Weight13.7 kg / 30.2 lb convertedManufacturer data sheet.[1]
Capacity100 AhManufacturer nominal rating.[1]
DimensionsW 335 × H 191 × D 174 mm / W 13.2 × H 7.52 × D 6.85 in convertedPublished L×W×H mapped to display W/H/D.[1]
Enclosure ratingIP66Manufacturer data sheet.[1]
Max series units4
RELiON publishes "4" against "Maximum Batteries Connected in Series" for RB100-D.
Where: Specifications panel, Electrical Specifications, row "Maximum Batteries Connected in Series"
[2]
Maximum charge100 A
RELiON publishes "100 A" against "Maximum Continuous Charge Current" for RB100-D.
Where: Specifications panel, Charge Specifications, row "Maximum Continuous Charge Current"
[2]
Peak discharge200 A
RELiON publishes "200 A (7.5 s ±2.5 s)" against "Peak Discharge Current" for RB100-D.
Where: Specifications panel, Discharge Specifications, row "Peak Discharge Current"
[2]
Nominal voltage12.8 VManufacturer nominal rating.[1]
Nominal energy1.28 kWhPublished as 1280 Wh.[1]
Terminal torque80 to 100 in-lb
Printed as "Terminal Torque 80 - 100 in-lbs (9 - 11 N-m)" in RELiON's document "RELiON datasheet linked from the RB100-D specifications panel" (PDF page 1), for the battery's main terminals.
Where: PDF page 1
[3]
Continuous charge100 APublished maximum continuous charge current.[1]
Maximum discharge100 A
RELiON publishes "100 A" against "Maximum Continuous Discharge Current" for RB100-D.
Where: Specifications panel, Discharge Specifications, row "Maximum Continuous Discharge Current"
[2]
Charge temperature-20 to 45 °C / -4 to 113 °F converted
RELiON publishes "-4 to 113 ºF (-20 to 45 ºC)" against "Charge Temperature*" for RB100-D.
Where: Specifications panel, Temperature Specifications, row "Charge Temperature*"
[2]
Continuous output1.28 kW Calculated
Calculated at nominal voltage using the documented continuous discharge current. Operating voltage and thermal limits apply.
Sources
Calculated: Nominal volts × continuous discharge amps ÷ 1,000
[1]
Storage temperature-5 to 35 °C / 23 to 95 °F converted
RELiON publishes "23 to 95 ºF (-5 to 35 ºC)" against "Recommended Storage Temperature" for RB100-D.
Where: Specifications panel, Temperature Specifications, row "Recommended Storage Temperature"
[2]
Continuous discharge100 APublished maximum continuous discharge current.[1]
Discharge temperature-20 to 60 °C / -4 to 140 °F converted
RELiON publishes "-4 to 140 ºF (-20 to 60 ºC)" against "Discharge Temperature" for RB100-D.
Where: Specifications panel, Temperature Specifications, row "Discharge Temperature"
[2]
Recommended charge range5 A - 50 A A
RELiON publishes "5 A - 50 A" against "Recommended Charge Current" for RB100-D.
Where: Specifications panel, Charge Specifications, row "Recommended Charge Current"
[2]
Recommended charge voltage14.2 V - 14.6 V V
RELiON publishes "14.2 V - 14.6 V" against "Recommended Charge Voltage" for RB100-D.
Where: Specifications panel, Charge Specifications, row "Recommended Charge Voltage"
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Basic specs
1.28 kWhDischarge 100 ACharge 100 APeak current: 200 A
$ / rated kWh
Unavailable
Warranty
10 yearsSee terms
Lifetime production
Not published
Size
11.13 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 335 × H: 191 × D: 174 mm / W: 13.2 × H: 7.52 × D: 6.85 in13.7 kg / 30.2 lb0.11 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)

Evidence score

10/10020% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.

12 V · Case battery · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Warranty term10 years10 / 20

10 years · 20% weight

10 of 20 years, the best documented for a small DC battery (printed by the maker): Bioenno Power 6V 3Ah LiFePO4 Battery (PVC, BLF-0603W)

Product-page limited warranty claim; full contract conditions require review.

50 / 100 × 20 = 10 points.

[4]

Lifetime / capacityNot documented0 / 20

No qualifying figure · 20% weight

Not published. No lifetime-production bonus.

Not documented. Undisclosed data scores 0.

[1]

Not documented, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
IEC 62133manufacturer claimunknown[2]
Scope
cell
Covered models
RB100-D
Limitations
RELiON's own page for RB100-D lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[2]
UL 1642manufacturer claimunknown[2]
Scope
cell
Covered models
RB100-D
Limitations
RELiON's own page for RB100-D lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[2]
UN 38.3manufacturer claimunknown[2]
Scope
battery pack scope unverified
Covered models
RB100-D
Limitations
RELiON's own page for RB100-D lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[2]
UL 1642manufacturer claim unresolvedunknown[1]
Scope
cell
Covered models
RB100-D
Limitations
Manufacturer sheet claims UL 1642 cells and file MH64523. Issuer record and installed cell identity were not checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term10 yearsProduct-page limited warranty claim; full contract conditions require review.[4]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Datasheets

  • RELiON RB100-D data sheetOfficial · RELiON · Official datasheet · PDF
    Certificate & compliance claims (1)
    UL 1642Manufacturer claim · cellClaimedStatus unconfirmed

    Manufacturer sheet claims UL 1642 cells and file MH64523. Issuer record and installed cell identity were not checked.

    Manufacturer document

    Official datasheet: RELiON RB100-D data sheet
    Source details
    Revision
    RB100-D DATA SHEET 05.10.23
    Revision date
    Not stated

    Revision date not established.

    Location: Original source record

    Retrieved Sep 7, 2026

    Open
  • Other documents

  • RELiON RB100-D product pageOfficial · RELiON · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Revision date not established.

    Location: Original source record

    Retrieved Sep 7, 2026

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • RELiON product page for RB100-D (Specifications panel)Official · RELiON Batteries · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured with playwright_chromium_rendered_dom_specifications_tab_opened.

    Location: Specifications panel, 42 published rows

    Retrieved Sep 18, 2026

    Manufacturer-operated product page for RB100-D, captured as rendered DOM with Playwright chromium because relionbattery.com answers a plain HTTPS GET with HTTP 403 and renders this table only after its Specifications tab is opened. It establishes what RELiON published on that page on the access date: the standards it names remain manufacturer statements, no issuer record was read, and no value here was taken from any other model's page.

    Open

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
RB100-D

Manufacturer SKU RB100-D · US market

  1. Observed Sep 18, 2026

    UN 38.3: claimed

    Battery pack claim; verification pending. RELiON's own page for RB100-D lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked.

    [2]

  2. Observed Sep 18, 2026

    UL 1642: claimed

    Cell / component only. RELiON's own page for RB100-D lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.

    [2]

  3. Observed Sep 18, 2026

    IEC 62133: claimed

    Cell / component only. RELiON's own page for RB100-D lists "UKCA & CE (battery); UN38.3 (battery); UL1642 (cells) (File# MH64523); IEC62133 (cells)" under Certifications. This is a manufacturer statement recorded against that exact model: no issuer listing, certificate number, edition, scope or validity was checked, and a cell-level standard does not establish product-level certification.

    [2]

  4. Observed Sep 7, 2026

    Document history

    Exact model research record created from the cited manufacturer evidence.

    [4] [1]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: UL 1642 · UN 38.3 +1
shown detail: Not scored
state: missing
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: 10
unit: years
shown: 10 years
shown detail: Unknown
state: documented
points: 10
ceiling: 20
weight: 20
share: 50
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [4]
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: no
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not published. No lifetime-production bonus.
display note: Unknown
Sources: [1]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. RELiON RB100-D data sheet (RELiON · manufacturer · RB100-D DATA SHEET 05.10.23 · observed Sep 7, 2026)
  2. RELiON product page for RB100-D (Specifications panel) (RELiON Batteries · manufacturer · observed Sep 18, 2026)
  3. RELiON datasheet linked from the RB100-D specifications panel (RELiON Batteries · manufacturer · observed Sep 18, 2026)
  4. RELiON RB100-D product page (RELiON · manufacturer · observed Sep 7, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details