XT60 Output*1 DC 12V-30A; USB-A*1 (5V,9V,12V, Max 18W)*1; USB-C*1 (5V,9V,12V,20V, Max 100W)*1; input GX16MF-5*1 DC Charging(12V~95V) Max 400W; Port For Cascade *2 (DC 24V)
Ports as the manual lists them, rearranged by row. The manual prints the USB-A and USB-C figures in an order that pairs "(5V,9V,12V,20V, Max 100W)" with USB-A and "(5V,9V,12V, Max 18W)" with USB-C; the list above follows the function-introduction figure (USB-C 100W, USB-A 18W) and the table text is kept in printed.
Where: PDF page 3, OUTPUT SPECS, INPUT SPECS and CASCADE FUNCTION
Printed as "DC Charging(12V~95V) Max 400W" in PECRON manual pecron_EB3000_user_manual 20221024, PECRON EB3000-24V user manual, PDF page 3, specification table, DC Charging row. Revised on 1 October 2026: The PECRON user manual prints 400 W; 0.4 kW is the same figure in kilowatts.
Where: PECRON EB3000-24V user manual, PDF page 3, specification table, DC Charging row
Printed as "3072Wh (25.6V120Ah)" in PECRON manual pecron_EB3000_user_manual 20221024, PECRON EB3000-24V user manual, PDF page 3, specification table, Capacity row. Revised on 1 October 2026: The PECRON user manual prints 3072 Wh; 3.072 kWh is the same figure in kilowatt-hours.
Where: PECRON EB3000-24V user manual, PDF page 3, specification table, Capacity row
Printed as "0℃~45℃/32°F~113°F (Charging)" (Temperature); ambient range in which the manual says the unit charges. Manufacturer claim, not an independent test.
Printed as "-20℃~45℃/-4°F~113°F (Discharging)"; ambient range in which the manual says the unit discharges. Manufacturer claim, not an independent test.
Not printed for this model in the documents on file. Revised on 1 October 2026: PECRON prints no lifetime energy figure; the stored value was computed from capacity and cycle life.
27.52 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 312 × H: 200 × L: 441 mm / W: 12.3 × H: 7.87 × L: 17.4 in26 kg / 57 lb0.11 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
4/10020% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
24 V · Portable expansion · Expansion · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for an expansion battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity3,500 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Not documented, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
PECRON manual pecron_EB3000_user_manual 20221024
Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
EB3000-24V
Manufacturer SKU EB3000-24V · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not assessed without a recorded parent system; UL 9540 not assessed without a recorded parent system.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 3,500 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.