Lithionics prints "The NX12V310 is designed for applications where high-current performance, compact packaging and simplified integration matter. Ideal for: High-power inverters and AC loads Electric motors and motor-driven equipment RV and marine house power systems" (Product page, Ideal Uses section (Built for High-Demand Systems)). The labels are the maker's own words: Marine from "marine"; RV and van from "RV".
Where: Product page, Ideal Uses section (Built for High-Demand Systems)
Printed as 300 A with footnote 1: maximum rates depend on the ambient temperature and usage. The product page describes the same figure as "300A Continuous".
Where: Datasheet DS-049 Rev.A page 2, SPECIFICATIONS, DISCHARGE, Max Discharge Current
Recorded as the datasheet prints it: UN38.3 approved, UL1642, and a UL1973 listing for the complete battery assembly marked pending. Page 1 of the datasheet prints "UL 1973 Pending for Motive Applications" and "COMING SOON". The product page instead prints "UL 1973 Certified" for the NX Series; because Lithionics' own datasheet marks the listing pending, no UL 1973 certification is recorded. No certificate or issuer record was read.
20.99 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 210.8 × H: 266.7 × L: 373.4 mm / W: 8.3 × H: 10.5 × L: 14.7 in27.6 kg / 60.8 lb0.19 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
5/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
12 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as 5 years or 3,000 full discharge and charge cycles, whichever is shorter. The warranty text on the page is Lithionics' general limited warranty for its batteries and does not name the NX12V310.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Printed as "UL1642" in the UL row of the CERTIFICATIONS section of Lithionics' NX Series 12V 310Ah datasheet DS-049 Rev.A, beside a UL1973 listing marked pending. Recorded exactly as printed. The datasheet does not say whether UL1642 applies to the cells or the battery, names no file number, and no issuer record was checked.
Printed as "UNDOT UN38.3 Approved" in the CERTIFICATIONS rows of Lithionics' NX Series 12V 310Ah datasheet DS-049 Rev.A, whose catalog number is printed as NX-12V310-A1508. Recorded exactly as printed. The datasheet names no test laboratory, report number or scope, no test summary was read, and no issuer record was checked.
Coverage ends at 3,000 cycles if that comes before 5 years; a cycle is printed as a full discharge and charge. This is a warranty limit, not a cycle-life specification.
Where: Product page, Warranty tab, Basic Coverage Period
Printed as 5 years or 3,000 full discharge and charge cycles, whichever is shorter. The warranty text on the page is Lithionics' general limited warranty for its batteries and does not name the NX12V310.
Where: Product page, Warranty tab, Basic Coverage Period
UN38.3Manufacturer claim · unresolved document setClaimedListed when checked
Printed as "UNDOT UN38.3 Approved" in the CERTIFICATIONS rows of Lithionics' NX Series 12V 310Ah datasheet DS-049 Rev.A, whose catalog number is printed as NX-12V310-A1508. Recorded exactly as printed. The datasheet names no test laboratory, report number or scope, no test summary was read, and no issuer record was checked.
UL1642Manufacturer claim · unresolved document setClaimedListed when checked
Printed as "UL1642" in the UL row of the CERTIFICATIONS section of Lithionics' NX Series 12V 310Ah datasheet DS-049 Rev.A, beside a UL1973 listing marked pending. Recorded exactly as printed. The datasheet does not say whether UL1642 applies to the cells or the battery, names no file number, and no issuer record was checked.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: Page 1 and page 2 SPECIFICATIONS
Retrieved Sep 28, 2026
Two-page Lithionics datasheet linked from the NX12V310 product page. It prints catalog number NX-12V310-A1508, which differs from the page's NX12V310-E1508, and marks the product coming soon with a UL 1973 listing pending. No date is printed. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by Lithionics Battery, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: Heading, overview and Warranty tab
Retrieved Sep 28, 2026
Lithionics' own product page, captured on September 28, 2026. It prints the catalog number, headline figures, a UL 1973 claim that the linked datasheet marks pending, and Lithionics' general limited warranty text. Manufacturer claims, not independently verified.
Archived copy of a document published by Lithionics Battery, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.