No product photos yet.
Fox ESS EQ5500-S (w) Support-pack Battery Module
No sellers found.
Key specs
Units- Chemistry
- Lithium Iron PhosphateOfficial user manual
Sources
The manual expressly names EQ5500(w) and states the battery chemistry of these products. No cell maker or cell model inferred.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 4, Notes on This Manual, expressly named EQ5500(w) scope
Documented
- Nominal energy
- 5.46 kWhOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Nominal energy (kWh)
Documented
- Nominal voltage
- 44.8 VOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Nominal voltage (V)
Documented
- Rated capacity
- 122 AhOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Rated capacity (Ah)
Documented
- Continuous discharge current
- 50 AOfficial user manual
Sources
Printed discharge/charge order retained; both continuous values explicitly printed.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Max. Continuous discharge/charge current (A)
Documented
- Continuous charge current
- 50 AOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Max. Continuous discharge/charge current (A)
Documented
- Standard charge current
- 50 AOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, (CC-CV) Standard charging current (A)
Documented
- Maximum discharge current
- 50 AOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Max. charge/discharge current (A)
Documented
6 specs not documented yet: usable energy, address / dip setting (manual), conductor sizes, terminal torque (manual), ground terminal torque (manual), external fuse breaker ratingHelp fill in ›
All specs51
- Chemistry
- Lithium Iron PhosphateOfficial user manual
Sources
The manual expressly names EQ5500(w) and states the battery chemistry of these products. No cell maker or cell model inferred.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 4, Notes on This Manual, expressly named EQ5500(w) scope
Documented
- Nominal energy
- 5.46 kWhOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Nominal energy (kWh)
Documented
- Usable energy
- Not documented
- Nominal voltage
- 44.8 VOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Nominal voltage (V)
Documented
- Rated capacity
- 122 AhOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Rated capacity (Ah)
Documented
- Continuous discharge current
- 50 AOfficial user manual
Sources
Printed discharge/charge order retained; both continuous values explicitly printed.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Max. Continuous discharge/charge current (A)
Documented
- Continuous charge current
- 50 AOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Max. Continuous discharge/charge current (A)
Documented
- Standard charge current
- 50 AOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, (CC-CV) Standard charging current (A)
Documented
- Maximum discharge current
- 50 AOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Max. charge/discharge current (A)
Documented
- Charge termination current
- 2 AOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Constant current and constant voltage charging cut-off current (A)
Documented
- Maximum charge current
- 50 AOfficial user manual
Sources
The table expressly names charge and discharge; charge termination and peak discharge are separate rows.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Max. charge/discharge current (A)
Documented
- Peak discharge current
- 65 AOfficial user manual
Sources
Peak for 60 seconds, as printed, not continuous current.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Peak discharge Current (60s) (A)
Documented
- Operating voltage range
- 40.6 to 51.1 VOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Battery voltage range (V)
Documented
Lifetime production
Published claims and calculations are not independently tested lifetime output.
- Battery weight
- 41 kg90 lb convertedWeight tolerance ±5%, as printed.Official user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Weight (kg)
Documented
- Dimensions
- 37.26 LW: 570 × H: 172 × D: 380 mmW: 22.4 × H: 6.77 × D: 15 in convertedOfficial user manual
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Dimensions (W*H*D) (mm)
Calculated
- Communications
- CANOfficial user manual
Sources
Printed in the exact warm-up model table, not transferred from the unsuffixed version.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Communication interfaces
Documented
- Storage temperature
- -10 to 35 °C14 to 95 °F convertedOfficial user manual
Sources
Exact warm-up table storage range; separate conditional storage chapter is retained under storage_schedule.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Storage temperature (°C)
Documented
- Fire protection
- aerosol fire extinguishing deviceOfficial user manual
Sources
Maker says each battery unit has a fire-protection module. This is not independent fire testing or an assurance of safety. Internal conflicting firefighting passages on PDF pages 14 and 16 remain separate. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 9, section 2.2.2 Fire Protection Function
Documented
- Charging temperature
- 0 to 55 °C32 to 131 °F convertedWarm-up function off; the warm-up-on range is retained separately with its condition.Official user manual
Sources
Footnote *1: warm up function off. Printed pair 0~55/-10~55, charge/discharge respectively. Footnote *2 gives a separate warm-up-on range, not a source disagreement. Internal cell-temperature control limits on PDF page 12 remain separate from these table operating ranges.
-25 to 55 °COfficial user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentFootnote *2: warm up function on. Printed pair -25~55/-25~55, charge/discharge respectively. This is a different operating condition, not a conflicting value or a transfer from another model.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Operating charge/discharge temperature, footnote *1
Documented
- Discharging temperature
- -10 to 55 °C14 to 131 °F convertedWarm-up function off; the warm-up-on range is retained separately with its condition.Official user manual
Sources
Footnote *1: warm up function off. Printed pair 0~55/-10~55, charge/discharge respectively. Footnote *2 gives a separate warm-up-on range, not a source disagreement. Internal cell-temperature control limits on PDF page 12 remain separate from these table operating ranges.
-25 to 55 °COfficial user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentFootnote *2: warm up function on. Printed pair -25~55/-25~55, charge/discharge respectively. This is a different operating condition, not a conflicting value or a transfer from another model.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Operating charge/discharge temperature, footnote *1
Documented
- Expansion requirements
- Installation: deviation of voltages between new batteries and every single present battery less than 0.5V; recommend new batteries comply to warranty scope or have ever been re-charged within 5 months; present battery system SOC 50%±5%.; Replacement/capacity expansion: each battery SOC consistent; max. SOC difference should be between±5%; existing system about 50%; manufacture date new battery shall not exceed 12 months, otherwise charge new battery to around 50%.Official user manual
Sources
Separate printed contexts retained. Odd between±5% wording not normalized to an invented inequality; no threshold calculated. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF pages 14 and 37, Installation and Expanded capacity requirement
Documented
- Features
- Battery Warm up functionOfficial user manual
Sources
Warm up function is exclusively available in warm-up versions. All batteries must be warm-up versions; otherwise the Warming up function will not operate. Heating control is based on internal cell temperature rather than ambient temperature. Battery can only discharge when internal temperature is above -10°C and only charge above 0°C. These internal-cell limits are separate from root-reviewed warm-up model-table operating ambient ranges. Self-heating state: SOC >= 10%, MinCell Temperature < Start Temperature, not in low-temperature protection, within set heating time. Resistor is powered by battery; inverter power control not affected. Inverter-controlled heating: SOC < 10% or in low-temperature protection, and MinCell Temperature < StartTemperature within set heating time. Resistor powered by inverter; inverter can only provide heating power and cannot respond to other charging/discharging requests. Page 11 app controls print heating start temperature 1~9℃ optional, stop 10~15℃ optional, and three time periods. Values are control settings, not battery charge/discharge operating limits.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 12, Exact warm-up module note; PDF pages 11-12 conditions and control settings
Documented
- Humidity
- 5 to 95 %Official user manual
Sources
5~95(No Condensing), as printed.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Humidity (%)
Documented
- Installation clearances (manual)
- Native diagram: rear ≥20 mm; top ≥300 mm; left ≥300 mm; right ≥300 mm.; Prose: To ensure proper heat dissipation of the battery pack, a reasonable clearance must be left around it (see the figure above for the specific distance).Official user manual
Sources
Q-only diagram and prose. No front distance printed in the reviewed diagram; do not invent one. Local installation/safety-clearance regulations apply. Natural convection requires the module exposed to ambient air; covering or shielding may stop operation. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 19, section 5.2 Clearance, native diagram and second note
Documented
- Cooling
- natural convectionOfficial user manual
Sources
The battery module must remain exposed to ambient air. The manual says entire or partial covering/shielding may cause the module to stop operating. Common named EQ5500(w) scope, no thermal performance inferred.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 19, Clearance, module-cooling note
Documented
- Address / DIP setting (manual)
- Not documentedOfficial user manual
Details
No address-setting procedure located. Module Addressing failed is a fault label only. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF pages 6-8, 24, 27 and 35-36; 53-page text keyword scan
Not documented
- Conductor sizes
- Not documentedOfficial user manual
Details
No AWG/mm² power or ground conductor gauge located. Native D and R labels describe cable diameter/bend geometry without a numerical conductor section. OT Terminal package label supplies no numerical gauge. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF pages 18 and 24-27; 53-page text keyword scan
Not documented
- Low SOC storage
- 0~35°C; 0% ≤ SOC < 5%; maximum charge interval 7 daysOfficial user manual
Sources
Power-off SOC before storage. Note says recharge within 7 days when SOC reaches 0%; permanent battery faults caused by customer-delayed charge are beyond warranty scope. No warranty duration inferred. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 37, section 7.3.2 Storage with Low SOC table
Documented
- Site restriction
- Do not install the equipment outdoors in salt-affected areas because it may be corroded.; Ensure the installation area is protected from direct sunlight, rain, and snow accumulation, a shelter (e.g., rain canopy) is recommended.Official user manual
Sources
Salt-affected area is within 1000 m of coast or prone to sea breeze, with weather/terrain qualifications. Area must be completely waterproof with hard level floor and wall without noticeable inclined angle; low stable humidity, ventilation, minimized dust/dirt. No market inferred. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF pages 14-15, sections 3.3 and 3.4
Documented
- Storage schedule
- Below -20°C: Not allowed; -20~0°C: 10%~90% RH; ≤1 months; 20%≤SOC≤50%; 0~35°C: 10%~90% RH; ≤6 months; 20%≤SOC≤50%; 35~55°C: 10%~90% RH; ≤1 months; 20%≤SOC≤50%; Above 55°C: Not allowedOfficial user manual
Sources
Recommended battery storage time is not more than 6 months. Each row keeps its RH, duration and SOC. Overlapping boundary values remain as printed. Conditional storage chapter is separate from the exact model-table storage row. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 17, Storage Requirement conditional table
Documented
- Battery fuse or breaker (manual)
- Internal Short Circuit, Over Voltage, Over Current, Over Temp, Under Voltage.Official user manualConflicting fire-response passages within the manual
EQ&TQ PDF page 14, Installation: In case of fire, use only dry powder fire extinguisher. Liquid extinguishers should not be used. PDF page 16, Fire Situation: In situations where the battery is on fire, if it is safe to do so, disconnect the battery module by turn off the circuit breaker to shut off the power to the system. Use FM-200 or CO₂ fire extinguisher for the battery and an ABC fire extinguisher for the other parts of the system. Under any fire situation, please evacuate the people from the building immediately before trying to extinguish it. Both passages remain as printed source evidence; no response procedure or independent safety recommendation is selected.
Sources
Maker battery-protection list. Inverter-interface protection is separately printed; no external fuse/breaker rating inferred. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 8, section 2.2.1 Battery Protection Function
Documented
- Maximum altitude m
- 3,000 m9,843 ft converted≤3000 m, as printed.Official user manual
Sources
Exact individual warm-up module rating, not a complete-system altitude.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Altitude (m)
Documented
- Terminal torque (manual)
- Not documentedOfficial user manual
Details
No numeric battery power-terminal torque located. Power connectors push until click. The RJ45-body torque is a separate scope. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 25 dedicated DC output procedure; 53-page text keyword scan
Not documented
- Installation area m2
- 10 m²No less than 10 m² for indoor installation, as printed.Official user manual
Sources
Indoor installation area must be no less than 10 m². Printed lower bound retained. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 19, indoor installation note
Documented
- Mounting orientation (manual)
- Stack the battery modules one by one.Official user manual
Sources
Bottom module is leveled using the footstand and spirit level. Check level before installing Main-pack; mark fixing brackets, drill holes and secure to wall. PDF page 23: L means number of system layers; L≤6 one pair Item D on Main-pack; L>6 one pair Main-pack plus an additional pair in middle Support-pack layer. Ground must support battery weight, and outdoors must be hard and leveled. No horizontal mounting inferred. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF pages 21-23, section 5.4 Installation Steps
Documented
- Installation location
- indoors or outdoorsOfficial user manual
Sources
The battery system can be installed indoors or outdoors, as printed. On a module record this is assembled-system installation context, not standalone operation or a separate market rating.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 19, Clearance, first note
Documented
- Depth of discharge
- 90 %Official user manual
Sources
Documented 90% for this exact warm-up model in EQ&TQ section 8.2. The shared EQ4800/EQ5500 manual unsuffixed 100% row is not an alternative for this code. No usable energy is derived.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 41, Depth of discharge (%)
Documented
- Ground terminal torque (manual)
- Not documentedOfficial user manual
Details
No numeric earth-terminal torque located in these reviewed passages or full-text keyword scan. M5 at the grounding inset is a screw-size label; mounting torque is a separate scope. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF pages 7-8 and 22-27; 53-page text keyword scan
Not documented
- Heat source clearance m
- 2 m6.6 ft convertedAt least 2 meters from heat sources, as printed.Official user manual
Sources
Battery system must be kept at least 2 meters away from heat sources. Printed lower bound retained. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 19, heat-source note
Documented
- Packing list as printed
- Support-pack: Mounting screwOfficial user manual
Sources
Separate printed component package lists only. Item D is Fixing bracket; Item G is Grounding cable. Only explicit *4 quantities retained; illustration counts not counted. No whole-system package quantity derived. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module. Exact warm-up module Model No. ties appear on PDF pages 41 and 42; this list is a component package, not a calculated configured-system package total.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 18, section 5.1 Items in the package
Documented
- Mounting fastener torque
- M6: 3~4 N·m; M5: 3~4 N·mOfficial user manual
Sources
M6 tool torque is printed at Step 5 and M5 at Step 6. These are mounting/bracket fastener torques, not battery power or earth-terminal torques. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 22, section 5.4 Steps 5-6 native diagrams
Documented
- Mounting hole dimensions
- φ: 8 mm; D: >50 mmOfficial user manual
Sources
Printed drill diameter and strict depth bound. Not a cable measurement. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 22, section 5.4 Step 4 native drill diagram
Documented
- Storage capacity loss claim
- If the battery is stored over one year,5%- 8% of the capacity may lose irreversibly.Official user manual
Sources
Printed conditional maker storage-loss claim. No annual degradation rate calculated. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 17, repeated storage Note
Documented
- External fuse breaker rating
- Not documentedOfficial user manual
Details
No numeric external fuse or breaker rating located. Protection and fault labels are not an external-device rating; model-table short-circuit current is not such a rating. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF pages 8, 16, 24-27 and 35-36; 53-page text keyword scan
Not documented
- Inverter voltage requirement
- the battery system voltage must meet the inverter battery port voltage rangeOfficial user manual
Sources
PDF page 14 prohibits exceeding inverter battery voltage rating and connecting an incompatible inverter. No exact compatible inverter list inferred. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 23, inverter warning; PDF page 14, section 3.3
Documented
- Storage recharge instruction
- no more than 0.5 C to the SOC of 50%Official user manual
Sources
Module stored between -20°C~55°C and recharged regularly according to conditional table after long storage. No ampere value calculated. Common EQ5500(w) storage guidance, separate from model-table operating or storage scalars.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 17, Storage Requirement paragraph
Documented
- Waterproof cover instruction
- The waterproof cover must be installed.Official user manual
Sources
Adjacent note also says screws must be installed. This mandatory named waterproof cover is distinct from optional protective cover on PDF page 26. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 22, Step 6 note
Documented
- System composition requirements
- Each system has only 1 Main-pack and a maximum of 8 Support-pack.Official user manual
Sources
PDF page 23 additionally says: Please make sure each system including 1 Main-pack and n Support-pack. Support-pack less than 8(1~8) pieces. Diagram prints Support-pack ≤8 Layers. Awkward less-than versus inclusive wording preserved; no component totals calculated. Exact warm-up system tables are separately reviewed by root. Assembled EQ5500(w) system. On either module record this remains stack-installation context, not an individual module dimension or standalone operating permission.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 6, Product Introduction; PDF page 23, installation note
Documented
- Fire protection discharge time s
- ≤5Official user manual
Sources
Fire-protection module discharge time, not electrical battery discharge duration. Common module fire-protection claim in the Q manual named EQ5500(w) scope.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 10, fire-protection Technical Specifications
Documented
- First installation manufacture interval
- shall not exceed 3 monthsOfficial user manual
Sources
Interval among battery-module manufacture dates for the first installation; not a warranty duration or a maximum battery age. Common EQ5500(w) family guidance within the expressly named manual scope on PDF page 4. Exact warm-up module names are printed on PDF page 12. This is an assembled battery system, not standalone operation of one module.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 17, first-installation note
Documented
- Fire protection activation temperature
- ≥170Official user manual
Sources
Thermal activation temperature of the fire-protection module. Not battery operating temperature. Common module fire-protection claim in the Q manual named EQ5500(w) scope.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentLocation: PDF page 10, fire-protection Technical Specifications
Documented
Published claims and calculations, not independent test results.
Documents
- PDFOpenFox ESS EQ&TQ Series user manual, V1.0.0, 2026-07Official
Our copy is kept as private evidence and is not available to download. SHA-256: d0d4c695b689c5426d564c25fe8f19334351b46ac6ea0fb29a5ae2cb6bb9cc6b, captured .
Source details
Printed Date 2026-07, with no day stated. Archived copy captured on 2026-11-04. The PDF filename is not used to infer a revision day.
Location: PDF pages 1-2, cover and version; PDF pages 44-45, exact EQ5000-S-P and EQ5000-M-P module tables; PDF pages 18-29, installation and wiring
Retrieved
Unchanged official Fox ESS PDF obtained through its native public download filter. Exact individual model tables govern these records; system-table figures are not transferred to modules. The printed month has no inferred day. Global is a download label, not a market. Reference app/Web screenshots supply no product facts. Manufacturer claims, not independent tests.
Warranty
No warranty terms on file.
Sellers
No sellers found.
Price history
No seller price history.
Owner reviews
No reviews yet
Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
48 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity0 / 20
No qualifying figure · 20% weight
Not published. No lifetime-production bonus.
Not documented. Undisclosed data scores 0.
Official user manual: Fox ESS EQ&TQ Series user manual, V1.0.0, 2026-07 Rev V1.0.0 · Checked · Earlier documentResearch pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
No certificates on file. Certificate guide
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- EQ5500-S (w)
Manufacturer SKU unknown
No historical observations recorded yet.
Community discussions
No discussions linked yet. Search DIY Solar Forum
Recalls / legal notices
No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice
Something wrong that is not one of the values above?
Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.