No product photos yet.
Fox ESS CQ7-L7 (w) High Voltage Storage Battery
No sellers found.
Key specs
Units- Chemistry
- Lithium Iron PhosphateOfficial installation manual
Sources
Explicit manual CQ7/CQ7(w) scope.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 5, Notes on This Manual
Documented
- Nominal energy
- 48.72 kWhOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) Nominal energy (kWh)
Documented
- Nominal voltage
- 403.2 VOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) Nominal voltage (V)
Documented
- Rated capacity
- 121 AhOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) Rated capacity (Ah)
Documented
- Standard charge current
- 50 AOfficial installation manual
Sources
Printed standard CHARGING current, not recommended discharge current.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, (CC-CV) Standard charging current (A)
Documented
- Maximum discharge current
- 80 AOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Max. charge/discharge current (A)
Documented
- Charge termination current
- 2 AOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Constant current and voltage charging cut-off current (A)
Documented
- Maximum charge current
- 80 AOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Max. charge/discharge current (A)
Documented
8 specs not documented yet: usable energy, fire response, address / dip setting (manual), maximum altitude m, terminal torque (manual), ground terminal torque (manual), external fuse breaker rating, power cable vertical lengthHelp fill in ›
All specs67
- Chemistry
- Lithium Iron PhosphateOfficial installation manual
Sources
Explicit manual CQ7/CQ7(w) scope.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 5, Notes on This Manual
Documented
- Nominal energy
- 48.72 kWhOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) Nominal energy (kWh)
Documented
- Usable energy
- Not documented
- Nominal voltage
- 403.2 VOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) Nominal voltage (V)
Documented
- Rated capacity
- 121 AhOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) Rated capacity (Ah)
Documented
- Standard charge current
- 50 AOfficial installation manual
Sources
Printed standard CHARGING current, not recommended discharge current.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, (CC-CV) Standard charging current (A)
Documented
- Maximum discharge current
- 80 AOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Max. charge/discharge current (A)
Documented
- Charge termination current
- 2 AOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Constant current and voltage charging cut-off current (A)
Documented
- Maximum charge current
- 80 AOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Max. charge/discharge current (A)
Documented
- Peak discharge current
- 120 AOfficial installation manual
Sources
Peak for 60 seconds, not continuous current.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Peak discharge current (60s) (A)
Documented
- Operating voltage range
- 365.4 to 459.9 VOfficial installation manual
Sources
Own exact column, not a family-wide range or calculation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, CQ7-L7 (w) Battery voltage range (V)
Documented
Lifetime production
Published claims and calculations are not independently tested lifetime output.
- Battery weight
- 358 kg789 lb converted358(1±5%) kg, as printed.Official installation manual
Sources
Printed whole-system expression 358(1±5%) kg. Base number and literal tolerance expression retained, not evaluated or summed.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, CQ7-L7 (w) Weight (kg)
Documented
- Dimensions
- 283.93 LW: 660 × H: 1,195 × D: 360 mmW: 26 × H: 47.05 × D: 14.2 in convertedOfficial installation manual
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
Sources
Printed whole-system dimensions, not summed. The tolerance heading is printed W*H*DH, retained without correction: ±3/±21/±3.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, CQ7-L7 (w) Dimensions (W*H*D) (mm)
Calculated
- Enclosure rating
- IP65Official installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Ingress protection
Documented
- Communications
- CANOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Communication interfaces
Documented
- Storage temperature
- -10 to 50 °C14 to 122 °F convertedOfficial installation manual
Sources
Exact model-table range. Separate storage-chapter schedule remains with its conditions.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Storage temperature (°C)
Documented
- Fire protection
- Each battery unit is equipped with a fire protection module using a new type of aerosol fire extinguishing device.Official installation manual
Sources
Manufacturer claim about an internal aerosol fire-protection device, separate from external emergency extinguishers. PDF page 11 prints activation at ≥170°C and discharge time ≤5 seconds, requires immediate replacement after activation, and warns against unauthorized disassembly or touching the device before the casing cools. Assembled-system context, not standalone module operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 9
Documented
- Charging temperature
- 0 to 55 °C32 to 131 °F convertedWarm-up function off; warm-up-on limits retained separately with their condition.Official installation manual
Sources
Printed pair is charge/discharge respectively. Footnote *1: warm up function off.
-25 to 55 °COfficial installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentWarm up function on; separate condition, not a disagreement. Internal cell thresholds are separate, and all batteries must be warm-up versions.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Operating charge/discharge temperature
Documented
- Discharging temperature
- -10 to 55 °C14 to 131 °F convertedWarm-up function off; warm-up-on limits retained separately with their condition.Official installation manual
Sources
Printed pair is charge/discharge respectively. Footnote *1: warm up function off.
-25 to 55 °COfficial installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentWarm up function on; separate condition, not a disagreement. Internal cell thresholds are separate, and all batteries must be warm-up versions.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Operating charge/discharge temperature
Documented
- Expansion requirements
- Please ensure on installation site that the deviation of voltages between new batteries and every single present battery is less than0.5V.; Recommend to check the new batteries mounted on-site comply to the warranty scope or have ever been re-charged within 5 months; on top of that, please make sure the SOC of present battery system onsite is50%±5%.; If a battery is replaced or added for capacity expansion, each battery’s SOC should be consistent. The max. SOC difference should be between ±5%.; If users want to increase their battery system capacity, please ensure that the SOC of the existing system capacity is about50%. The manufacturer date of the new battery shall not exceed12 months; in case of exceeding12 months. please charge the new battery to around50%.Official installation manual
Sources
Separate new/existing battery instructions retained; do not combine manufacture-date intervals with first-installation interval. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 15, 38
Documented
- Grounding (manual)
- Before wiring, ensure the grounding cable (Item I) is securely connected. Please ensure the reliability of the battery ground cable.Official installation manualGrounding cable item label differs between the package and wiring note
PDF page 19 labels the Grounding cable K and the PV connector removal tool I. PDF page 28 calls the grounding cable Item I. Both labels remain as printed; no component is relabeled.
Sources
Native PDF28 earth connection and note read visually. The note says Item I, but native PDF19 package labels Grounding cable Item K and PV connector removal tool Item I. Keep discrepancy; do not relabel silently. No numeric earth-terminal torque/ground conductor gauge located. CQ-M external Earth Terminal on complete system; not a separately labeled CQ-S external terminal.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 8, 19, 28
Documented
- Monitoring
- FoxCloud APP or FoxCloud Web platformOfficial installation manual
Sources
Battery monitored and controlled by inverter after successful installation/commissioning and correct communication. Inverter terminal-layout diagram reference only; actual wiring per exact inverter manual. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 32
Documented
- Startup without grid power
- Under special circumstances when both PV and Grid power are out of order, the battery can be activated through the "Black Start" function. This means that our energy storage inverter and battery can continue to operate.; Turn on the DC Switch, press and hold the “POWER” button for 3 seconds, then release.; Press the “POWER” button three times in succession within 4 seconds (Complete within 30 seconds after the battery system starts up).; The Status LED remains solid green, indicating successful activation of Black Start mode.; Ensure correct battery-inverter connection prior to Black Start. No wiring modifications during black start.Official installation manual
Sources
All full printed operation passages/warning retained. Not generic inverter compatibility or standalone-module capability. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 31
Documented
- Installation clearances (manual)
- Rear ≥20 mm; top ≥900 mm; left ≥600 mm; right ≥600 mm.Official installation manual
Sources
Native diagram read visually. No numerical front clearance printed. Prose refers to the figure for specific distances and says local installation/safety-clearance rules apply; module exposed to ambient air and cooled by natural convection. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 20
Documented
- Fire response
- Sources disagreeUnresolvedOfficial installation manualThe manual prints different fire-extinguisher directions
PDF page 15 says dry powder only; PDF page 16 names FM-200 or CO2 for the battery and ABC for other parts. Both full passages are retained; no procedure is selected.
Why values differ
Two complete fire-agent passages in one manual differ. Preserve both and warning; select no fire procedure. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
In case of fire, use only dry powder fire extinguisher. Liquid extinguishers should not be used.Literal printed passage or diagram label, retained with its physical PDF locator. No instruction is selected between differing passages.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentIn situations where the battery is on fire, if it is safe to do so, disconnect the battery pack by turn off the circuit breaker to shut off the power to the system. Use FM-200 or CO2 fire extinguisher for the battery and an ABC fire extinguisher for the other parts of the system. Under any fire situation, please evacuate the people from the building immediately before trying to extinguish it.Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLiteral printed passage or diagram label, retained with its physical PDF locator. No instruction is selected between differing passages.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 15, 16
Sources disagree
- Cooling
- natural convectionOfficial installation manual
Sources
The battery module must be exposed to ambient air; covering or shielding may cause it to stop operating. No thermal rating inferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 20, Clearance, fourth note
Documented
- Address / DIP setting (manual)
- Not documentedOfficial installation manual
Details
No address/DIP-setting procedure located in full manual text and viewed installation/operation pages. ModuleAddressingfailed fault label is not a setting procedure. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 8, 25, 28, 35, 37
Not documented
- Conductor sizes
- DC output cable (Wire gauge 16 mm²)Official installation manual
Sources
Native package Item L DC output cable. This does not state ground-cable size and does not become an AWG conversion. CQ-M package/system external DC output connection; not separately supplied CQ-S cable.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 19
Documented
- Low SOC storage
- 0~35℃; Power-Off SOC Before Storage0%≤SOC<5%; Maximum Charge Interval7days. When the battery SOC decreases to0%, charge the batteries within7days. Permanent battery faults caused by delayed charge due to customer reasons are beyond the warranty scope.Official installation manual
Sources
Printed low-SOC context, not warranty duration. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 38
Documented
- Protective class
- Class ⅠOfficial installation manual
Sources
Transcribed from the exact CQ7 model table; no sibling or regional scalar transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Protective class
Documented
- Site restriction
- Do not install the equipment outdoors in salt-affected areas because it may be corroded. A salt-affected area refers to the region within1000 m of the coast or prone to sea breeze. Regions prone to sea breeze vary with weather conditions (such as typhoons and monsoons) or terrains (such as dams and hills).Official installation manual
Sources
Keep full condition; not a country/market basis. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 15
Documented
- Storage schedule
- Below -20℃: Not allowed.; -20~0℃; relative humidity10%~90%; storage time≤1months;20%≤SOC≤50%.; 0~35℃; relative humidity10%~90%; storage time≤6months;20%≤SOC≤50%.; 35~55℃; relative humidity10%~90%; storage time≤1months;20%≤SOC≤50%.; Above55℃: Not allowed.Official installation manualThe storage chapter and exact model tables print different ranges
PDF page 18 describes storage from -20°C to +55°C with time, relative humidity, SOC and recharge conditions. PDF pages 52-59 print -10~50°C for the exact models. Both contexts are retained without replacing either range or choosing a storage procedure.
Sources
Storage chapter conditions, separate from PDF52-59 table storage temperature-10~50℃. Retain both with their own locators/conditions; no silent selection. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 18
Documented
- Warm up function
- This feature is exclusively available in the warm-up versions.; Please check that the wiring is properly connected and that all batteries are the warm up versions; otherwise, the Warming up function will not operate.; Warming up control is based on the internal cell temperature of the battery, rather than the ambient temperature.Official installation manual
Sources
PDF page 13 states that warm-up control uses internal cell temperature, rather than ambient temperature: discharge only above -10°C and charge only above 0°C. All batteries must be warm-up versions for the function to operate. These are distinct from the exact model-table operating ranges. Assembled-system context, not standalone module operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 11, 13
Documented
- Cable bending radius / connector notes (manual)
- R: ≥6×D; angle ≥90°Official installation manual
Sources
Native bend diagram; D labels cable diameter. No numeric radius calculated from wire area or diameter. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 28
Documented
- Cycle life cycles
- 6,000 cycles≥6000 cycles @25°C @70%SOH, as printed.Official installation manual
Sources
Printed lower bound ≥6000 at 25°C and 70% SOH; no unprinted DoD/rate inferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Cycle life
Documented
- Battery fuse or breaker (manual)
- Inverter interface protection: Over Voltage, Over Current, External Short Circuit, Reverse Polarity, Ground Fault, Over Temp, In Rush Current.; Battery protection: Internal Short Circuit, Over Voltage, Over Current, Over Temp, Under Voltage.Official installation manual
Sources
Printed protection claims, not external protection device ratings. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 9
Documented
- Maximum altitude m
- Not documentedOfficial installation manual
Details
Exact system table has no altitude row. Module ≤3000 m is not transferred.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 57-59
Not documented
- Start up procedure
- When the inverter is connected to the PV and the grid and both are operating normally, turn on the battery DC Switch. Press the POWER Switch and hold it for 3 seconds, then release. The Status LED is blinking green and indicates that the system is working normally.Official installation manual
Sources
Section6.1. Opening note says grid-connected inverter turned on first; all operations comply local electrical standards; check power/communication cables. No second manual/procedure selected. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 30
Documented
- Terminal torque (manual)
- Not documentedOfficial installation manual
Details
No numeric DC power terminal torque located; plugs illustrated without torque. RJ45 1.2±0.2N·m and mounting torque not substituted. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 8, 23, 25, 26, 28
Not documented
- Battery designation
- IFpP53/150/120[(18S)7S]M/-10+50/90Official installation manual
Sources
Literal native cell with line wraps joined; not decoded or treated as an ordering SKU.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) Battery designation
Documented
- Communication ports (manual)
- CAN, RJ45. CONN.1 PIN/CONN.2 PIN: 1 A-START; 2 GND; 3 /; 4 BMS-CANL; 5 BMS-CANH; 6 BMS-CANH; 7 BMS-CANL; 8 /. Default wire harness PIN to PIN.Official installation manual
Sources
Native CQ-M external interface and PDF28 pin table. PDF25 says BAT side to battery and INV side to inverter. PDF28 says connect other end into inverter BMS port; follow inverter user manual. No external RJ45 assigned to CQ-S. CQ-M external interface on complete system; do not assign standalone RJ45/CAN port to CQ-S.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 8, 25, 28
Documented
- Shut down procedure
- Press and hold the POWER Switch for at least 5 seconds until all of the main battery LEDs (BMS Status LED and SOC LED) begin blinking. Once they start blinking, release the switch. The lights will automatically turn off after 5 seconds. Then, turn off the DC Switch.Official installation manual
Sources
Section6.2 complete procedure. PDF29 disassembly Step1 states POWER off then DC off, without timings; retain as separate disassembly context, not contradictory control topology. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 30
Documented
- Communication terminal torque (manual)
- 1.2±0.2Official installation manual
Sources
Step3: Use an open-end spanner to lock the body onto the RJ45 board end connector; torque: 1.2±0.2N·m. Tolerance retained. Not DC or earth torque. CQ-M RJ45 external connector on complete system.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 25
Documented
- Installation area m2
- 10 m²No less than 10 m² for indoor installation, as printed.Official installation manual
Sources
For indoor installation scenarios, the installation area must be no less than 10 m². Printed minimum, not a system-specific area calculation. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 20
Documented
- Mounting orientation (manual)
- Install the bottom battery module, level it using the footstand, and use a spirit level to verify that it is level. Stack the battery modules one by one.Official installation manual
Sources
Native steps show standing stack, CQ-M on top, fixed to wall; floor must support weight and be hard/level outdoors. No wall-hung or horizontal installation inferred. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 22, 23
Documented
- Disassembly procedure
- First turn off the POWER Switch, and then turn off the DC Switch,all LEDs are off when POWER Switch is turned off. After shutting down the system, there is no current flow between the support units. Then disconnect the wiring harness connected to the inverter.Official installation manual
Sources
Native Step1. Subsequent steps remove waterproof cover, screws, CQ-M and CQ-S; do not touch stacking connector male label on figure. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 29
Documented
- Discharge capacity
- 97.6@-20±2℃ @1/3C; 121@25±2℃ @1/3C; 121@55±2℃ @1/3COfficial installation manual
Sources
Each printed temperature, tolerance and rate retained; separate from rated capacity.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Discharge capacity (Ah)
Documented
- Fixing bracket layout
- When L ≤ 6, a pair of Item C is installed on CQ-M;; When L >6, a pair of Item C is installed on CQ-M, and install an additional pair of Item C in the middle layer of the CQ-S modules.; When 11 ≤ L ≤14, a pair of Item C is installed on CQ-M, and install 2 additional pairs of Item C on 5th layer and 10th layer CQ-S.Official installation manual
Sources
L is number of layers in battery system. Preserve overlapping printed conditions, do not choose or simplify a bracket procedure. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 24
Documented
- Installation location
- indoors or outdoorsOfficial installation manual
Sources
Assembled-system installation context. The salt-affected outdoor restriction and local regulations remain separately cited.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 20, Clearance, first note
Documented
- Depth of discharge
- 90 %Official installation manual
Sources
Exact printed value. No usable energy derived.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 58, Depth of discharge (%)
Documented
- Ground terminal torque (manual)
- Not documentedOfficial installation manual
Details
No numeric earth-terminal torque located in full text and viewed installation diagrams. M6/M5 3~4 N·m PDF23 are mounting torques, not substituted. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 8, 23, 25, 28
Not documented
- Heat source clearance m
- 2 m6.6 ft convertedAt least 2 meters from heat sources, as printed.Official installation manual
Sources
The battery system must be kept at least 2 meters away from heat sources. Printed minimum. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 20
Documented
- Mounting fastener torque
- Step 5: M6, 3~4 N·m.; Step 6: M5, 3~4 N·m.Official installation manual
Sources
Both native torque callouts read visually. These are bracket/module mounting screws, not power or earth-terminal torque. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 23
Documented
- Mounting hole dimensions
- φ: 8mm; D: >50mmOfficial installation manual
Sources
Native Step4 drill callout; bore depth strict greater-than as printed, not ≥50. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 23
Documented
- Power cable installation
- For the DC output cable, connect the end marked "DC+" and "DC-" to the battery, and connect the opposite end marked "BAT+" and "BAT-" to the inverter.; Do not interchange the positive and negative terminals of the battery.Official installation manual
Sources
Full warning retained. Native diagram uses keyed plug connections; no terminal type inferred. CQ-M/system external DC connector.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 26
Documented
- Storage capacity loss claim
- If the battery is stored over one year, 5%-8% of the capacity may lose irreversibly.Official installation manual
Sources
Maker statement, not independent test. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 18
Documented
- Battery module configuration
- 1CQ7-M (w)+6CQ7-S (w)Official installation manual
Sources
Printed component counts, not arithmetic used for totals.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 57, CQ7-L7 (w) The number of batteries
Documented
- External fuse breaker rating
- Not documentedOfficial installation manual
Details
No numerical external fuse or breaker rating located in independently extracted full 68-page text or reviewed installation diagrams. Circuit-breaker mention in Fire Situation and HVB/Module FUSE fault labels do not give a rating. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF pages 16, 25, 26, 28, 37
Not documented
- Inverter voltage requirement
- When used with an inverter, the battery system voltage must meet the inverter battery port voltage range.Official installation manual
Sources
No inverter model, rating or compatibility list inferred. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 24
Documented
- Protective cover instruction
- The protective cover is optional.Official installation manual
Sources
Different from required waterproof cover PDF23. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 27
Documented
- Storage recharge instruction
- The battery module should be stored in an environment with a temperature range between -20℃- +55℃, and charged regularly according to the table below with no more than 0.5 C(A C-rate is a measure of the rate at which a battery is discharged relative to its maximum capacity.)to the SOC of50% after a long time of storage.Official installation manual
Sources
Exact extracted paragraph from independently parsed original, spacing may be typographic extraction. No own recharge schedule inferred. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 18
Documented
- Waterproof cover instruction
- The screws must be installed. The waterproof cover must be installed.Official installation manual
Sources
Both notes printed. Protective cover in PDF27 is separately described as optional, so do not conflate covers. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 23
Documented
- Power cable vertical length
- Sources disagreeUnresolvedOfficial installation manualDifferent minimum vertical cable lengths printed on the same page
The diagram prints ≥100 mm while the warning prose says greater than30mm. Both are retained; no selected minimum is supplied.
Why values differ
Native diagram prints ≥100 mm; adjacent warning prose says vertical length greater than30mm. Same diagram/prose context retained without choosing an interpretation or replacing either value. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
≥100 mmLiteral printed passage or diagram label, retained with its physical PDF locator. No instruction is selected between differing passages.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentMake sure that the power cable connected to the battery is connected vertically and that the vertical length is greater than30mm. If the cable is bent close to the terminals, it may cause poor line contact and result in burnt terminals.Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLiteral printed passage or diagram label, retained with its physical PDF locator. No instruction is selected between differing passages.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 28
Sources disagree
- System composition requirements
- CQ-S is the battery module, and CQ-M includes system controller and battery module. Ensure that each system has only 1 CQ-M and a maximum of 13 CQ-S.Official installation manual
Sources
Exact family roles printed in introduction. PDF24 prints 1 CQ-M and CQ-S less than 13(1~13) pieces, with diagram ≤13 layers; do not silently correct the wording. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 7
Documented
- Fire protection discharge time s
- 5 s≤5 seconds, as printed.Official installation manual
Sources
Printed upper bound for the internal aerosol fire-protection device, not a battery operating temperature or external fire procedure.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 11, Fire Protection Function
Documented
- First installation manufacture interval
- For the first installation, the interval among manufacture dates of battery modules shall not exceed 3 months.Official installation manual
Sources
Printed maximum age difference, not product service life. assembled CQ7 family system; on a module record this describes its installation through the stack, not standalone operation.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 18
Documented
- Fire protection activation temperature
- 170 °C338 °F converted≥170°C, as printed.Official installation manual
Sources
Printed lower bound for the internal aerosol fire-protection device, not a battery operating temperature or external fire procedure.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentLocation: PDF page 11, Fire Protection Function
Documented
Published claims and calculations, not independent test results.
Documents
- PDFOpenFox ESS CQ Series user manual, V1.0.5, 2026-07Official
Our copy is kept as private evidence and is not available to download. SHA-256: 264b09fba8dde64c98b6938bd5e509463b9485625d520bd26cfc4f6ce9400f2c, captured .
Source details
Archived copy captured on 2026-11-04.
Location: PDF page 1 scope; PDF page 2 revision/date; PDF pages 48-51 CQ6.6 (w) exact tables
Retrieved
Original official PDF from Alternative Research native download-filter capture; independently verified and reviewed. English, labeled Global; no country applicability inferred. Copyright notice retained, no figure or photo cropped for public reuse.
Warranty
No warranty terms on file.
Sellers
No sellers found.
Price history
No seller price history.
Owner reviews
No reviews yet
Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
High-voltage stacked batteries · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity0 / 20
No qualifying figure · 20% weight
Not published. No lifetime-production bonus.
Not documented. Undisclosed data scores 0.
Official installation manual: Fox ESS CQ Series user manual, V1.0.5, 2026-07 Rev V1.0.5 · July 2026 · Checked · Earlier documentResearch pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
No certificates on file. Certificate guide
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- CQ7-L7 (w)
Manufacturer SKU unknown
No historical observations recorded yet.
Community discussions
No discussions linked yet. Search DIY Solar Forum
Recalls / legal notices
No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice
Something wrong that is not one of the values above?
Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.