DC battery module
Deka Duration DD300-12H LiFePO4 battery (12.8 V, 300 Ah) with heater
Key specs
3 specs not documented yet: nominal energy, usable energy, recommended discharge currentHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Chemistry | LiFePO4 | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Mechanical; Cell Type - Electrolyte | [2] |
| Terminals | Threaded insert, M8 bolt | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Where: PDF page 5, 1.4 Mechanical; Threaded Insert and M8 Bolt; power terminals, not CAN connectors | [2] |
| Use cases | Marine, Off-grid | Deka Duration Smart LFP Batteries brochure, no printed date or revision; cover says BY MK BATTERY; third-party hosted by Solar Electric Supply. Printed Marine and Renewable Energy / Off-Grid Systems. Existing two use labels retained; no new uses inferred. Where: PDF page 2, Applications | [1] |
| Weight | 37.5 kg / 82.7 lb converted | Deka Duration Smart LFP Batteries brochure, undated; exact DD300-12H row, read natively. Printed metric figures are used directly; no value transferred from the nonheated column. Where: PDF page 2, DD300-12H row; Weight - lbs (kg) | [1] |
| Cycle life | 6,000 cycles | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Printed 6K at 80% DoD. Where: PDF page 5, 1.4 Performance; Cycles | [2] |
| Capacity | 300 Ah | Deka Duration Smart LFP Batteries brochure, undated; exact DD300-12H row, read natively. Printed metric figures are used directly; no value transferred from the nonheated column. Where: PDF page 2, DD300-12H row; Ah Capacity | [1] |
| Self heating | yes | Deka Duration Smart LFP Batteries brochure, undated; exact DD300-12H row, read natively. Printed metric figures are used directly; no value transferred from the nonheated column. Where: PDF page 2, DD300-12H row; Model star and *Heated Model footnote | [1] |
| Case material | ABS+PC Fire Rated | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Mechanical; Case Material | [2] |
| Dimensions | W 264.2 × H 233.7 × L 500.3 mm / W 10.4 × H 9.2 × L 19.7 in converted | Deka Duration Smart LFP Batteries brochure, undated; exact DD300-12H row, read natively. Printed metric figures are used directly; no value transferred from the nonheated column. Where: PDF page 2, DD300-12H row; Dimensions - L x W x H - Inches (mm) | [1] |
| Terminal size | M8 | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Mechanical; Terminal Hole | [2] |
| Battery format | Case battery DetailsCharged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim. Deka Duration Smart LFP Batteries brochure, no printed date or revision; cover says BY MK BATTERY; third-party hosted by Solar Electric Supply. Printed Group 27 and 8D footprint. Site classification as case, not a maker taxonomy. Source datasheet: Deka Duration Smart LFP Batteries brochure (undated)Location: PDF page 2, Benefits, Drop-in Replacement | ||
| Communications | CAN | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. CAN is optional; Modbus requires the separately described DD-T-BOX hub, not a native battery Modbus claim. Where: PDF page 17, 3.5.1; CAN optional, DD-T-BOX Modbus hub described on PDF 16 | [2] |
| Address setting | The battery connected to external equipment is the Master; all others are Subs. On the Master only, press and hold CONFIG for about 10 seconds until the lights cycle and turn off to confirm address matching. | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Where: PDF page 18, 3.5.2; Master only, CONFIG about10s until LEDs cycle/off | [2] |
| Enclosure rating | IP67 | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Mechanical; IP Rating | [2] |
| Max series units | 4 batteries | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 14, 3.3, combined bank limits on PDF 15 | [2] |
| Nominal voltage | 12.8 V | Deka Duration Smart LFP Batteries brochure, no printed date or revision; cover says BY MK BATTERY; third-party hosted by Solar Electric Supply. Printed 12.8V nominal lithium iron phosphate chemistry; the manual performance row uses the generic 12V system class. Where: PDF page 2, Features, 12V LiFePO4 | [1] |
| Series connection | yes | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 12, 3.1, series requirements on PDF 14 | [2] |
| Cycle life dod | 80 % | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Performance; Cycles | [2] |
| Max parallel units | 16 count | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 12, 3.2; ONLY at 12V, combined bank table PDF 15 | [2] |
| Terminal torque | 8 to 12 N·m | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Mechanical; Terminal Torque | [2] |
| Communication ports | Link In and Link Out CAN-bus ports for battery-to-battery and system communication and firmware updates | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Where: PDF page 10, 2.4 rowG plus PDF 17; Link In/Out CAN, firmware updates; M8 DIN versus M12 naming conflict remains unresolved, no connector selected | [2] |
| Charge temperature | -20 to 60 °C / -4 to 140 °F converted | Deka Duration Smart LFP Batteries brochure, undated; exact DD300-12H row, read natively. Heated-model range as printed. The Mar. 9 manual PDF 7 says heating with charger connected activates below 0 C and warms to 10 C before charging; it also prints a separate -10 to 0 C, at most 0.05C allowance. These statements are retained without inferring a procedure or a cell threshold. Where: PDF page 2, DD300-12H row; Temperature; Charge & Discharge | [1] |
| Heating activation | 0 °C / 32 °F converted | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. With a charger connected the heater activates below 0 C and warms to 10 C before charging. The same paragraph separately prints -10 to 0 C charging only at or below 0.05C; no operating instruction or threshold is inferred. Where: PDF page 7, 1.6 Heating Function (for heating modules) | [2] |
| Mounting orientation | Face-up on a stable and level surface; not on its side or upside down | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Where: PDF page 8, 2.2; face-up, stable/level, never side/upside-down | [2] |
| Storage temperature | 15 to 35 °C / 59 to 95 °F converted | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Temperature; Storage Temperature | [2] |
| Discharge temperature | -20 to 60 °C / -4 to 140 °F converted | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Temperature; Discharge Temperature | [2] |
| Operating temperature | -20 to 60 °C / -4 to 140 °F converted | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 5, 1.4 Temperature; Operational Temperature | [2] |
| Other compliance claims | Certifications: UN38.3, UL 1973 Recognized Component, IEC62619, CE; Cell: UN38.3, UL9540A, UL1642 | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Manufacturer claims only; battery/component and cell rows are separate. No issuer record was checked and no verified status is asserted. Where: PDF page 5, 1.4 Certifications; manufacturer claim only, battery row separate from cell row; no issuer-status upgrade | [2] |
| Recommended discharge | Unknown | The previously cited document is no longer used as evidence. No eligible maker document reviewed establishes this fact for the exact model; the earlier value remains in the record history. | No source on record |
| Internal resistance | 30 mΩ | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Printed as internal resistance <30 milliohm; value is an upper bound, not a measured 30. Where: PDF page 5, 1.4 Performance; Resistance; LESS THAN30mOhm, not a measured30 | [2] |
| Recommended charge voltage | 14.2 V | Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Where: PDF page 6, 1.5; 12V system row; float13.8V and absorption14.2–14.6V remain separate | [2] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Basic specs
- Not yet documentedDischarge UnknownCharge Unknown
- $ / rated kWh
- Unavailable
- Warranty
- UnknownSee terms
- Lifetime production
- Not published
- Size
- 30.89 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 264.2 × H: 233.7 × L: 500.3 mm / W: 10.4 × H: 9.2 × L: 19.7 in37.5 kg / 82.7 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
12 V · Case battery · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
20 × 0.2 = 4 points.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
UL 1973manufacturer claimpresent at observation[2] [1]
- Scope
- recognized component
- Covered models
- DD300-12H
- Limitations
- Manufacturer recognized-component claim, not a finished-battery listing. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Certifications row prints UN38.3, UL 1973 Recognized Component, IEC62619, CE; the undated maker brochure PDF page 2 repeats UL 1973 Recognized Component. No certificate, report number or issuer status was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Nov 9, 2026
- Source
- [2] [1]
UL 9540Amanufacturer claimpresent at observation[2] [1]
- Scope
- cell
- Covered models
- DD300-12H
- Limitations
- Manufacturer claim at cell level, not an assembled-battery certification. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Cell row prints UN38.3, UL9540A, UL1642. The undated maker brochure, PDF page 2, prints Cell-level UL 9540A testing. No test report number or issuer record was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Nov 9, 2026Edition as printed: Not printed
- Source
- [2] [1]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Deka Duration Installation Guide and User Manual, release Mar. 9, 2026Open
Our copy is kept as private evidence and is not available to download. SHA-256: e5ec7176252cff3804b84128d38be4e43a845e3115d484b8b6d4f8c00e11b231, captured .
Certificate & compliance claims (2)
UL 1973Manufacturer claim · recognized componentClaimedListed when checked
Manufacturer recognized-component claim, not a finished-battery listing. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Certifications row prints UN38.3, UL 1973 Recognized Component, IEC62619, CE; the undated maker brochure PDF page 2 repeats UL 1973 Recognized Component. No certificate, report number or issuer status was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
Manufacturer document
Source instruction manual: Deka Duration Installation Guide and User Manual, release Mar. 9, 2026UL 9540AManufacturer claim · cellClaimedListed when checked
Manufacturer claim at cell level, not an assembled-battery certification. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Cell row prints UN38.3, UL9540A, UL1642. The undated maker brochure, PDF page 2, prints Cell-level UL 9540A testing. No test report number or issuer record was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
Manufacturer document
Source instruction manual: Deka Duration Installation Guide and User Manual, release Mar. 9, 2026Source details
Independent native-page review on 2026-11-09; new permitted copy, not a byte-parity claim with a prohibited capture.
Location: PDF pages 1-21
Retrieved Nov 9, 2026
Manufacturer-authored document hosted by independent distributor Solar Electric Supply. Printed release Mar. 9, 2026; no equivalence to another manual edition claimed.
Datasheets
- Deka Duration Smart LFP Batteries brochure (undated)Open
Our copy is kept as private evidence and is not available to download. SHA-256: c54c093d7a32afba6e45370ac4166ad0e8acae32627ab5db1f054c75eab6210b, captured .
Source details
Independent native-page review on 2026-11-09; new permitted copy, not a byte-parity claim with a prohibited capture.
Location: PDF pages 1-2
Retrieved Nov 9, 2026
Manufacturer-authored document hosted by independent distributor Solar Electric Supply. Native cover prints BY MK BATTERY; no printed date or revision.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- DD300-12H
Manufacturer SKU DD300-12H
Observed Nov 9, 2026
UL 1973: claimed
Product / system scope unresolved. Manufacturer recognized-component claim, not a finished-battery listing. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Certifications row prints UN38.3, UL 1973 Recognized Component, IEC62619, CE; the undated maker brochure PDF page 2 repeats UL 1973 Recognized Component. No certificate, report number or issuer status was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
Observed Nov 9, 2026
UL 9540A: claimed
Cell / component only. Manufacturer claim at cell level, not an assembled-battery certification. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Cell row prints UN38.3, UL9540A, UL1642. The undated maker brochure, PDF page 2, prints Cell-level UL 9540A testing. No test report number or issuer record was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: 0.21-personal documented pct: 20 basis: nominal missing: Certificates evidence needed Warranty term needed Warranty energy disclosure evidence needed Cell model disclosure evidence needed criteria: key: certificateEvidence label: Certificates value: 0 unit: evidence points shown: UL 1973 · UL 9540A shown detail: Research pending state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules. display note: Unknown Sources: No source on record key: years label: Warranty term value: Unknown unit: years shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: throughputEvidence label: Warranty energy disclosure value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment. display note: Unknown Sources: No source on record key: lifetime label: Lifetime / capacity value: Unknown unit: MWh/kWh shown: 6,000 cycles shown detail: Unknown state: documented points: 4 ceiling: 20 weight: 20 share: Unknown covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh. display note: Unknown Sources: [2] key: cellDisclosure label: Cell model disclosure value: 0 unit: disclosure points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 5 weight: 5 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Deka Duration Smart LFP Batteries brochure (undated) (MK Battery · manufacturer document third party hosted · observed Nov 9, 2026)Our copy is kept as private evidence and is not available to download. SHA-256: c54c093d7a32afba6e45370ac4166ad0e8acae32627ab5db1f054c75eab6210b, captured .
- Deka Duration Installation Guide and User Manual, release Mar. 9, 2026 (MK Battery · manufacturer document third party hosted · observed Nov 9, 2026)Our copy is kept as private evidence and is not available to download. SHA-256: e5ec7176252cff3804b84128d38be4e43a845e3115d484b8b6d4f8c00e11b231, captured .
Sign in to report an error on this page