Charged ReviewsSaved 0Compare 0Login
No photo yet
Deka
DC battery module

Deka Duration DD100-12 LiFePO4 battery (12.8 V, 100 Ah)

Key specs

Nominal voltage12.8 V
Capacity100 Ah
Weight11.79 kg / 25.99 lb converted
Cycle life6,000 cycles
Recommended charge50 A

5 specs not documented yet: nominal energy, usable energy, continuous discharge current, continuous charge current, self-heatingHelp fill in ›

All specifications

Identity

BrandDeka · Website
ModelDD100-12
MarketUnknown
Manufacturer SKUDD100-12
About brandDeka is the battery brand of East Penn Manufacturing Co. of Lyon Station, Pennsylvania, a family-owned company its History page says was started in 1946. Deka solar batteries (flooded, AGM and gel) and Deka Duration lithium iron phosphate batteries are sold through its subsidiary MK Battery.
SKU detail
locator: PDF page 2, exact DD100-12 Model row
conditions: Same recorded code, explicitly printed in the maker-authored brochure table; native cover says BY MK BATTERY. Re-citation only under the LE 2026-11-09 11:45Z exact-code ruling; no new SKU inferred from ratings.
Sources: [1]
FieldValueConditionsSource
ChemistryLiFePO4
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Mechanical; Cell Type - Electrolyte
[2]
TerminalsThreaded insert, M8 bolt
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed.
Where: PDF page 5, 1.4 Mechanical; Threaded Insert and M8 Bolt; power terminals, not CAN connectors
[2]
Use casesMarine, Off-grid
Deka Duration Smart LFP Batteries brochure, no printed date or revision; cover says BY MK BATTERY; third-party hosted by Solar Electric Supply. Printed Marine and Renewable Energy / Off-Grid Systems. Existing two use labels retained; no new uses inferred.
Where: PDF page 2, Applications
[1]
Weight11.79 kg / 25.99 lb converted
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Nonheated column only; no H transfer. Surge3s for 100Ah,5s for 300/460Ah. Max300/460Ah currents require busbars per PDF 12. Printed pounds/inches converted to SI where needed; conversion is ours, not an SI figure printed by maker.
Where: PDF page 5, 1.4 exact DD100-12 column
Sources
11.8 kg

The undated maker brochure prints kilograms directly. The primary Mar. 9, 2026 manual prints pounds, converted by Research to two decimal places. Rounding and source precision differ; no more precise maker measurement or edition equivalence is asserted.

[1]
[2]
Cycle life6,000 cycles
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Printed 6K at 80% DoD.
Where: PDF page 5, 1.4 Performance; Cycles
[2]
Capacity100 Ah
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Nonheated column only; no H transfer. Surge3s for 100Ah,5s for 300/460Ah. Max300/460Ah currents require busbars per PDF 12. Printed pounds/inches converted to SI where needed; conversion is ours, not an SI figure printed by maker.
Where: PDF page 5, 1.4 exact DD100-12 column
[2]
Self heatingUnknown
The previously cited document is no longer used as evidence. No eligible maker document reviewed establishes this fact for the exact model; the earlier value remains in the record history.
No source on record
Case materialABS+PC Fire Rated
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Mechanical; Case Material
[2]
DimensionsW 167.64 × H 210.82 × L 307.34 mm / W 6.6 × H 8.3 × L 12.1 in converted
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Nonheated column only; no H transfer. Surge3s for 100Ah,5s for 300/460Ah. Max300/460Ah currents require busbars per PDF 12. Printed pounds/inches converted to SI where needed; conversion is ours, not an SI figure printed by maker.
Where: PDF page 5, 1.4 exact DD100-12 column
Sources
W 167.6 × H 210.8 × L 307.3 mm

Brochure prints millimeters directly; the primary manual prints inches, converted by Research. The displayed precision differs; no edition equivalence or more precise maker measurement is asserted.

[1]
[2]
Terminal sizeM8
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Mechanical; Terminal Hole
[2]
Battery format
Case battery
Site classificationBased onSource datasheet
Details

Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.

Deka Duration Smart LFP Batteries brochure, no printed date or revision; cover says BY MK BATTERY; third-party hosted by Solar Electric Supply. Printed Group 27 and 8D footprint. Site classification as case, not a maker taxonomy.

Source datasheet: Deka Duration Smart LFP Batteries brochure (undated)

Location: PDF page 2, Benefits, Drop-in Replacement

CommunicationsCAN
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. CAN is optional; Modbus requires the separately described DD-T-BOX hub, not a native battery Modbus claim.
Where: PDF page 17, 3.5.1; CAN optional, DD-T-BOX Modbus hub described on PDF 16
[2]
Address settingThe battery connected to external equipment is the Master; all others are Subs. On the Master only, press and hold CONFIG for about 10 seconds until the lights cycle and turn off to confirm address matching.
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed.
Where: PDF page 18, 3.5.2; Master only, CONFIG about10s until LEDs cycle/off
[2]
Enclosure ratingIP67
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Mechanical; IP Rating
[2]
Max series units4 batteries
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 14, 3.3, combined bank limits on PDF 15
[2]
Peak discharge500 A
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Nonheated column only; no H transfer. Surge3s for 100Ah,5s for 300/460Ah. Max300/460Ah currents require busbars per PDF 12. Printed pounds/inches converted to SI where needed; conversion is ours, not an SI figure printed by maker. Surge limit for 3 seconds on DD100-12; 5 seconds on DD300-12 and DD460-12.
Where: PDF page 5, 1.4 exact DD100-12 column
[2]
Nominal voltage12.8 V
Deka Duration Smart LFP Batteries brochure, no printed date or revision; cover says BY MK BATTERY; third-party hosted by Solar Electric Supply. Printed 12.8V nominal lithium iron phosphate chemistry; the manual performance row uses the generic 12V system class.
Where: PDF page 2, Features, 12V LiFePO4
[1]
Series connectionyes
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 12, 3.1, series requirements on PDF 14
[2]
Cycle life dod80 %
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Performance; Cycles
[2]
Included equipmentInter-communication cable (20 in, 500 mm, M12 connectors at both ends), battery, two M8 x 16 stainless steel screws, four mounting brackets
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. One inter-communication cable, 20 inches (500 mm), M12 interfaces at both ends; one battery; two M8 x 16 stainless steel screws; four brackets for DD100-12 and DD100-12H only. This is the cable description, not a resolution of the separate M8 DIN versus M12 battery-port wording.
Where: PDF page 9, 2.3 Component List; bracket footnote explicitly DD100-12 and DD100-12H
[2]
Max parallel units16 count
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 12, 3.2; ONLY at 12V, combined bank table PDF 15
[2]
Terminal torque8 to 12 N·m
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Mechanical; Terminal Torque
[2]
Communication portsLink In and Link Out CAN-bus ports for battery-to-battery and system communication and firmware updates
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed.
Where: PDF page 10, 2.4 rowG plus PDF 17; Link In/Out CAN, firmware updates; M8 DIN versus M12 naming conflict remains unresolved, no connector selected
[2]
Continuous chargeUnknown
The Mar. 9, 2026 manual prints Max Charge 100 A. This is not identified as a continuous rating, so the continuous value is unknown. The printed maximum is retained only in these cited conditions; no numeric maximum is assigned to the continuous field.
Where: PDF page 5, 1.4 Specifications, exact nonheated model column
[2]
Charge temperature0 to 60 °C / 32 to 140 °F converted
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed.
Where: PDF page 5, 1.4; Non Heated Model Charge Temperature
[2]
Mounting orientationFace-up on a stable and level surface; not on its side or upside down
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed.
Where: PDF page 8, 2.2; face-up, stable/level, never side/upside-down
[2]
Recommended charge50 A
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Nonheated column only; no H transfer. Surge3s for 100Ah,5s for 300/460Ah. Max300/460Ah currents require busbars per PDF 12. Printed pounds/inches converted to SI where needed; conversion is ours, not an SI figure printed by maker.
Where: PDF page 5, 1.4 exact DD100-12 column
[2]
Storage temperature15 to 35 °C / 59 to 95 °F converted
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Temperature; Storage Temperature
[2]
Continuous dischargeUnknown
The Mar. 9, 2026 manual prints Max Discharge 150 A. This is not identified as a continuous rating, so the continuous value is unknown. The printed maximum is retained only in these cited conditions; no numeric maximum is assigned to the continuous field.
Where: PDF page 5, 1.4 Specifications, exact nonheated model column
[2]
Discharge temperature-20 to 60 °C / -4 to 140 °F converted
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Temperature; Discharge Temperature
[2]
Operating temperature-20 to 60 °C / -4 to 140 °F converted
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 5, 1.4 Temperature; Operational Temperature
[2]
Other compliance claimsCertifications: UN38.3, UL 1973 Recognized Component, IEC62619, CE; Cell: UN38.3, UL9540A, UL1642
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Manufacturer claims only; battery/component and cell rows are separate. No issuer record was checked and no verified status is asserted.
Where: PDF page 5, 1.4 Certifications; manufacturer claim only, battery row separate from cell row; no issuer-status upgrade
[2]
Recommended discharge50 A
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Nonheated column only; no H transfer. Surge3s for 100Ah,5s for 300/460Ah. Max300/460Ah currents require busbars per PDF 12. Printed pounds/inches converted to SI where needed; conversion is ours, not an SI figure printed by maker.
Where: PDF page 5, 1.4 exact DD100-12 column
[2]
Internal resistance30 mΩ
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18. Printed as internal resistance <30 milliohm; value is an upper bound, not a measured 30.
Where: PDF page 5, 1.4 Performance; Resistance; LESS THAN30mOhm, not a measured30
[2]
Recommended charge voltage14.2 V
Deka Duration Installation Guide and User Manual, release Mar. 9, 2026, obtained from Solar Electric Supply. This is the edition read; no equivalence to the previously cited April edition is assumed. Shared manual row; cover names all six models. Cycles retain80% DoD. Parallel16 applies only12V; combined4S/4P, and2S/8P exception only without inter-battery communications. Source scope is March 9, not April 18.
Where: PDF page 6, 1.5; 12V system row; float13.8V and absorption14.2–14.6V remain separate
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Basic specs
Not yet documentedDischarge 50 A recommendedCharge 50 A recommendedPeak current: 500 A
$ / rated kWh
Unavailable
Warranty
UnknownSee terms
Lifetime production
Not published
Size
10.86 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 167.64 × H: 210.82 × L: 307.34 mm / W: 6.6 × H: 8.3 × L: 12.1 in11.79 kg / 25.99 lb

Evidence score

4/100Missing details20% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

12 V · Case battery · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Lifetime / capacity6,000 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

[2]

Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1973manufacturer claimpresent at observation[2] [1]
Scope
recognized component
Covered models
DD100-12
Limitations
Manufacturer recognized-component claim, not a finished-battery listing. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Certifications row prints UN38.3, UL 1973 Recognized Component, IEC62619, CE; the undated maker brochure PDF page 2 repeats UL 1973 Recognized Component. No certificate, report number or issuer status was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Nov 9, 2026
Source
[2] [1]
UL 9540Amanufacturer claimpresent at observation[2] [1]
Scope
cell
Covered models
DD100-12
Limitations
Manufacturer claim at cell level, not an assembled-battery certification. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Cell row prints UN38.3, UL9540A, UL1642. The undated maker brochure, PDF page 2, prints Cell-level UL 9540A testing. No test report number or issuer record was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Nov 9, 2026
Edition as printed: Not printed
Source
[2] [1]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Deka Duration Installation Guide and User Manual, release Mar. 9, 2026MK Battery · Source instruction manual · PDF

    Our copy is kept as private evidence and is not available to download. SHA-256: e5ec7176252cff3804b84128d38be4e43a845e3115d484b8b6d4f8c00e11b231, captured .

    Certificate & compliance claims (2)
    UL 1973Manufacturer claim · recognized componentClaimedListed when checked

    Manufacturer recognized-component claim, not a finished-battery listing. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Certifications row prints UN38.3, UL 1973 Recognized Component, IEC62619, CE; the undated maker brochure PDF page 2 repeats UL 1973 Recognized Component. No certificate, report number or issuer status was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.

    Manufacturer document

    Source instruction manual: Deka Duration Installation Guide and User Manual, release Mar. 9, 2026
    UL 9540AManufacturer claim · cellClaimedListed when checked

    Manufacturer claim at cell level, not an assembled-battery certification. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Cell row prints UN38.3, UL9540A, UL1642. The undated maker brochure, PDF page 2, prints Cell-level UL 9540A testing. No test report number or issuer record was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.

    Manufacturer document

    Source instruction manual: Deka Duration Installation Guide and User Manual, release Mar. 9, 2026
    Source details
    Revision
    Mar. 9, 2026
    Revision date
    Not stated

    Independent native-page review on 2026-11-09; new permitted copy, not a byte-parity claim with a prohibited capture.

    Location: PDF pages 1-21

    Retrieved Nov 9, 2026

    Manufacturer-authored document hosted by independent distributor Solar Electric Supply. Printed release Mar. 9, 2026; no equivalence to another manual edition claimed.

    Open
  • Datasheets

  • Deka Duration Smart LFP Batteries brochure (undated)MK Battery · Source datasheet · PDF

    Our copy is kept as private evidence and is not available to download. SHA-256: c54c093d7a32afba6e45370ac4166ad0e8acae32627ab5db1f054c75eab6210b, captured .

    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Independent native-page review on 2026-11-09; new permitted copy, not a byte-parity claim with a prohibited capture.

    Location: PDF pages 1-2

    Retrieved Nov 9, 2026

    Manufacturer-authored document hosted by independent distributor Solar Electric Supply. Native cover prints BY MK BATTERY; no printed date or revision.

    Open

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
DD100-12

Manufacturer SKU DD100-12

  1. Observed Nov 9, 2026

    UL 1973: claimed

    Product / system scope unresolved. Manufacturer recognized-component claim, not a finished-battery listing. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Certifications row prints UN38.3, UL 1973 Recognized Component, IEC62619, CE; the undated maker brochure PDF page 2 repeats UL 1973 Recognized Component. No certificate, report number or issuer status was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.

    [2] [1]

  2. Observed Nov 9, 2026

    UL 9540A: claimed

    Cell / component only. Manufacturer claim at cell level, not an assembled-battery certification. The Mar. 9, 2026 Deka Duration Installation Guide and User Manual, PDF page 5, Cell row prints UN38.3, UL9540A, UL1642. The undated maker brochure, PDF page 2, prints Cell-level UL 9540A testing. No test report number or issuer record was checked. Both documents were independently obtained from Solar Electric Supply on November 9, 2026. The former captures are no longer cited; the prior versions remain in history.

    [2] [1]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: UL 1973 · UL 9540A
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 6,000 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [2]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Deka Duration Smart LFP Batteries brochure (undated) (MK Battery · manufacturer document third party hosted · observed Nov 9, 2026)
    Our copy is kept as private evidence and is not available to download. SHA-256: c54c093d7a32afba6e45370ac4166ad0e8acae32627ab5db1f054c75eab6210b, captured .
  2. Deka Duration Installation Guide and User Manual, release Mar. 9, 2026 (MK Battery · manufacturer document third party hosted · observed Nov 9, 2026)
    Our copy is kept as private evidence and is not available to download. SHA-256: e5ec7176252cff3804b84128d38be4e43a845e3115d484b8b6d4f8c00e11b231, captured .

Sign in to report an error on this page

Similar products

All with a price