Charged ReviewsSaved 0Compare 0Login
Zendure SuperBase Pro 1500
Zendure
Portable power station

Zendure SuperBase Pro 1500

Key specs

Capacity1,440 Wh Check note
AC output2,000 W
Weight18.8 kg / 41.4 lb converted
Solar input2,400 W
Cycle life6,000 cycles
Surge output4,000 W

1 spec not documented yet: usable capacityHelp fill in ›

All specifications

Identity

BrandZendure · Website
ModelSuperBase Pro 1500
MarketUS · Also listed for EU
Manufacturer SKUZDSBP1500-BK-US
SKU detail
locator: products[].variants[].sku for the "SuperBase Pro 1500" variant of superbase-pro-2000
conditions: Zendure's ordering SKU for the SuperBase Pro 1500 alone on its US store, printed as "sku":"ZDSBP1500-BK-US" in the listing captured on September 26, 2026. Kits with solar panels carry other SKUs.
Sources: [1]
FieldValueConditionsSource
PortsAC outlet × 6 (100-120V~50/60Hz, US and JP versions); USB-C × 4 (C1/C2 5-20V, 100W max each; C3/C4 5-12V, 20W max total); car charger port × 1 (13.6V 10A); DC5521 × 3 (13.6V 10A, 136W max total with the car port); AC charge input (also accepts 60-160Vmp solar, 1,800W max); XT60 solar input (12-60Vmp 10A, 600W max); car charge input (12V/24V 10A battery)
Listed as printed; the manual prints "6*AC Ports" with the note "The EU version has 4 AC Outlets". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Outputs and Inputs
[2]
ChemistryLiFePO4
The manual prints "Cell Chemistry LiFePO4" (the manual's text is drawn as outlines and cannot be extracted); the store FAQ prints "SuperBase Pro 1500 uses LFP (LiFePO4) batteries".
Where: Manual PDF page 3, Battery, Cell Chemistry; store FAQ
[2] [3]
Weight18.8 kg / 41.4 lb converted
Printed as "≈ 41.45lbs /18.8kg". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, General, Weight
[2]
AC input1,800 W
Printed as "1,800W Max", with 1500W given in parentheses for the JP version, for 100-120V (US, JP version) or 220-240V (other versions). The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Inputs, AC Charge
[2]
Cycle life6,000 cycles
Printed as "6,000 cycles"; remaining capacity and test conditions are not stated. The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Battery, Cycle Life
[2]
AC output2,000 W
The manual prints "Pure Sine Wave, rated 2,000W (surge 4,000W), 100-120V~50/60Hz (US, JP version) or 220-240V~50/60Hz (Other versions)" and notes "The EU version has 4 AC Outlets". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Outputs, 6*AC Ports; store feature copy
[2] [3]
Capacity30 Ah
Printed as "1,440Wh (30Ah/48V)". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, General, Capacity
[2]
Capacity1,440 Wh Check note
Manual and store page differ. Zendure's SuperBase Pro 1500 user manual prints 1,440Wh (30Ah/48V); the store FAQ prints 1,456Wh.
The manual prints "Capacity 1,440Wh (30Ah/48V)". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked. The store FAQ prints "SuperBase Pro 1500 uses LFP (LiFePO4) batteries and has a charge capacity of 1,456Wh".
Where: Manual PDF page 3, 1. Specifications, General, Capacity; store FAQ
Sources
1,456 Wh

Printed as "SuperBase Pro 1500 uses LFP (LiFePO4) batteries and has a charge capacity of 1,456Wh".

[3]
[2] [3]
DimensionsW 276 × H 352 × L 446 mm / W 10.9 × H 13.9 × L 17.6 in converted
Printed as "17.5 × 10.5 × 13.8in / 446 x 276 x 352mm"; the axis order is not labeled. The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, General, Dimensions
[2]
Solar input2,400 W
The manual prints "12-60Vmp 10A DC, 600W Max via XT60 input", "60-160Vmp 11A DC, 1,800W Max via AC input" and "Total AC+DC MPPT,2400W". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Inputs, Solar Charge
[2]
Surge output4,000 W
Printed as "(surge 4,000W)"; the duration is not stated. The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Outputs, 6*AC Ports
[2]
Maximum AC charging1.8 kW
Converted: 1800 W / 1000 W/kW
The manual prints "1,800W Max" (rendered page, not machine-checked). 1800 W expressed in kW.
Where: Manual PDF page 3, Inputs, AC Charge
Sources
Converted: 1800 W / 1000 W/kW
[2]
Transfer time13 ms
Printed as "Featuring UPS functionality with a swift 13ms activation time" for "SuperBase Pro"; the manual lists an Offline UPS section without a time on its specification page.
Where: Store feature copy, Advanced UPS & BMS Technology
[3]
Nominal voltage48 V
Printed as "1,440Wh (30Ah/48V)". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, General, Capacity
[2]
Rated capacity1.44 kWh
Converted: 1440 Wh / 1000 Wh/kWh
The manual prints "Capacity 1,440Wh (30Ah/48V)" (rendered page, not machine-checked); 1440 Wh expressed in kWh.
Where: Manual PDF page 3, General, Capacity
Sources
Converted: 1440 Wh / 1000 Wh/kWh
[2]
AC output voltage120 V
Printed as "100-120V~50/60Hz (US, JP version)"; 120 V is the upper end of the printed range for the US version. The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Outputs, 6*AC Ports
[2]
Charge temperature0 to 40 C / 32 to 104 °F converted Check note
Manual and store page differ. The user manual prints a charge range of 0°C to 40°C; the store FAQ prints 0°C to 45°C.
Printed as "32°F to 110°F (0°C to 40°C)". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Temperature, Charge Temperature
Sources
0 to 45 C

Printed as "Charge: 0°C to 45°C (32°F to 113°F)" for "SuperBase Pro".

[3]
[2]
Continuous output2 kW
Converted: 2000 W / 1000 W/kW
The manual prints "rated 2,000W" (rendered page, not machine-checked). 2000 W expressed in kW.
Where: Manual PDF page 3, Outputs, 6*AC Ports
Sources
Converted: 2000 W / 1000 W/kW
[2]
Storage temperature0 to 45 C / 32 to 113 °F converted
Printed as "32°F to 110°F (0°C to 45°C)". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Temperature, Storage Temperature
[2]
Discharge temperature-20 to 40 C / -4 to 104 °F converted Check note
Manual and store page differ. The user manual prints a discharge range of -20°C to 40°C; the store FAQ prints -20°C to +60°C.
Printed as "-4°F to 140°F (-20°C to 40°C)"; the Fahrenheit and Celsius figures printed together do not correspond. The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, Temperature, Discharge Temperature
Sources
-20 to 60 C

Printed as "Discharge: -20°C to +60°C (-4°F to 140F)" for "SuperBase Pro".

[3]
[2]
Wireless communicationsWi-Fi; cell network and GPS supported
Printed as "Wireless Type Wi-Fi" and "Cell Network & GPS Supported". The manual's text is drawn as outlines and cannot be extracted; the figure was read from PDF page 3 (1. Specifications) rendered as an image, so the printed text is quoted here and not machine-checked.
Where: Manual PDF page 3, General, Wireless Type and Cell Network & GPS
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Battery capacity
1,440 WhValue needs confirmation: Manual and store page differChemistry LiFePO4 · Cycle life 6,000 cycles
Rated AC output
2,000 WSurge AC output 4,000 W
Solar input limit
2,400 W
Solar input voltage
Not stated
Weight
18.8 kg / 41.4 lbDimensions 276 W × 352 H × 446 L mm / 10.9 W × 13.9 H × 17.6 L in

Evidence score

8/100Missing details40% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

Power stations · 120 V AC · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Warranty term2 years4 / 20

2 years · 20% weight

2 of 10 years, the best documented for a power station (printed by the maker): Briggs & Stratton PowerBank 5.4 battery powered generator (5.4 kWh, 1,600 W)

Printed as "SuperBasePro 1500 2 Years"; accessories carry 1 Year. The table gives no start basis, transfer or remedy terms in the row.

20 / 100 × 20 = 4 points.

[4]

Lifetime / capacity6,000 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

[2]

Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term2 years
Printed as "SuperBasePro 1500 2 Years"; accessories carry 1 Year. The table gives no start basis, transfer or remedy terms in the row.
Where: Warranty Period table, SuperBasePro 1500 row
[4]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Other documents

  • Zendure US Download Center (September 26, 2026 capture)Official · Zendure · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Power Stations: manual links

    Retrieved Sep 26, 2026

    Zendure's US Download Center page (the address redirected to /pages/download-center-1), captured on September 26, 2026. Kept as the page that links each SuperBase and Satellite Battery user manual cited here; no specification is read from it.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Zendure SuperBase Pro 1500 User Manual (file SBP1500_202211-01)

Archived copy of a document published by Zendure. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 11.52 MB

Archived copy, unaltered, kept as a record of what Zendure published. Original address: https://cdn.shopifycdn.net/s/files/1/0276/0192/8266/files/SBP1500_202211-01_12862166-4c11-4acb-b691-c3a241e125c7.pdf?v=1677222396. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
15

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 2ab20fec3c51c09396fa0ead01d22e4bee35dd5ff4cc9d699d0bdb28a999a66b

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SuperBase Pro 1500

Manufacturer SKU ZDSBP1500-BK-US · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: 2
unit: years
shown: 2 years
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [4]
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 6,000 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [2]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Zendure US store product listing, products.json (September 26, 2026 capture) (Zendure · manufacturer · observed Sep 26, 2026)
  2. Zendure SuperBase Pro 1500 User Manual (file SBP1500_202211-01) (Zendure · manufacturer · observed Sep 26, 2026)
  3. Zendure SuperBase Pro Power Station, US store product description (JSON, September 26, 2026 capture) (Zendure · manufacturer · observed Sep 26, 2026)
  4. Zendure US Warranty Information page (September 26, 2026 capture) (Zendure · manufacturer · observed Sep 26, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details