AC Output ×2: AC 240V, 50Hz, total 1600W; Cigarette Lighter Socket Output: DC 12V, 10A; DC Output ×2: DC 12V, 3A; USB-A Output ×2: DC 5V, 3A; DC 9V, 2A; DC 12V, 1.5A, 18W Max; USB-C Output ×2: DC 5V/9V/12V/15V, 3A; DC 20V, 5A, 100W Max; Wireless Charge: 9V, 10W; AC Input: 200V-260V, 4.5A, 50Hz, 800W; PV Input: DC 800W; Car Charging: DC 12/24V, 8A
Ports as the specification table lists them; the cigarette lighter and DC outputs share a total of DC 12V, 10A.
Renogy's RPS1600AA manual prints two solar input figures. The RPS1600AA user manual (Version A0, October 20, 2025) prints "PV Input DC 800W" in its specification table and "Support 100W~400W solar panel charging" in its solar charging section. The table figure is shown first; both are Renogy's own claims.
Printed as "PV Input DC 800W" in the specification table. The manual's solar charging section prints "Support 100W~400W solar panel charging", kept as an alternative.
Where: Specifications, PDF page 16, PV Input
Sources
400 W
Printed as "Support 100W~400W solar panel charging" in the manual's solar charging section; the specification table prints "PV Input DC 800W".
15.6 kg / 34.4 lbDimensions 262 W × 266 H × 360 L mm / 10.3 W × 10.5 H × 14.2 L in
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
Power stations · 120 / 240 V AC · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "The warranty is 24 months, and the warranty period is calculated by the original consumer purchaser from the date of purchase."; 24 months expressed in years.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
FCC Part 15manufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RPS1600AA Series
Limitations
Renogy's RPS1600AA user manual Version A0 (October 20, 2025), captured on September 26, 2026, prints "FCC Statement This device complies with Part 15 of the FCC Rules." although the unit is sold on Renogy's Australian store with 240V outlets. No FCC ID is printed and no issuer record was read. Manufacturer claim only.
IEC 62477-1manufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RPS1600AA Series
Limitations
Renogy's RPS1600AA user manual Version A0 (October 20, 2025), captured on September 26, 2026, prints "This UPS complies with environmental service condition 3K2 of IEC 62477-1 (indoor use, pollution degree 2)". The statement concerns an environmental service condition named in that standard; no test report, laboratory or certificate is printed, and no issuer record was read. Manufacturer claim only.
Printed as "The warranty is 24 months, and the warranty period is calculated by the original consumer purchaser from the date of purchase."; 24 months expressed in years.
IEC 62477-1Manufacturer claim · unresolved document setClaimedListed when checked
Renogy's RPS1600AA user manual Version A0 (October 20, 2025), captured on September 26, 2026, prints "This UPS complies with environmental service condition 3K2 of IEC 62477-1 (indoor use, pollution degree 2)". The statement concerns an environmental service condition named in that standard; no test report, laboratory or certificate is printed, and no issuer record was read. Manufacturer claim only.
FCC Part 15Manufacturer claim · unresolved document setClaimedListed when checked
Renogy's RPS1600AA user manual Version A0 (October 20, 2025), captured on September 26, 2026, prints "FCC Statement This device complies with Part 15 of the FCC Rules." although the unit is sold on Renogy's Australian store with 240V outlets. No FCC ID is printed and no issuer record was read. Manufacturer claim only.
Renogy's own user manual for the RPS1600AA Series portable power station, linked from its Australian store page and captured on September 26, 2026. It prints "USER MANUAL VERSION A0 October 20, 2025". The Specifications section (PDF page 16) prints battery, dimensions, weight, AC input and output (240V, 50Hz), PV input, UPS switching time, ports and temperatures; the Additional information block (PDF page 17) prints an IP20 rating and an IEC 62477-1 service-condition statement; the Warranty section prints a 24-month term; it also prints an FCC Part 15 statement. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: SKU line; Specification table; Download link; product media gallery
Retrieved Sep 26, 2026
Renogy's own Australian store page on au.renogy.com (prices in AUD), captured on September 26, 2026, printing "SKU: RPS1600AA-AU". Its Specification table prints capacity, dimensions, weight, AC input and output (240V, 50Hz), PV input, UPS switching time, DC outputs and temperatures. It links the user manual. It carries no revision date. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Renogy 1075.2Wh Portable Power Station RPS1600AA User Manual, Version A0, October 20, 2025
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
RPS1600AA
Manufacturer SKU RPS1600AA-AU · AU market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: IEC 62477-1 · FCC Part 15
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.