conditions: Printed as "SKU: RPS2220AA" on Renogy's support page for this model, captured on September 26, 2026; the Manuals Center index lists the same SKU.
Ports as the specification table lists them. The extracted table prints the port names and values in separate runs; they are paired here in the printed order. The number of AC outlets (x1/x2) depends on the regional edition.
The DC Input row prints "10V~25V 4A, 60W Max"; the manual's solar charging section connects the solar panel to the DC Input Port. Total input with USB-C is printed as 120W Max.
Where: Specifications, DC Input, printed page 19 (PDF page 20); Solar Charging, printed page 10
Printed as "The operating voltage of the solar panel shall exceed 10V, and the open circuit voltage shall NOT exceed 25V." The DC Input row prints "10V~25V 4A, 60W Max".
Printed as "100V (JP)/120V (US, CA)/220V~240V (EU, UK, AU, KR, CN) 50Hz/60Hz, 200W Rated, 400W Surge" in Renogy PHOENIX 200 Portable Power Station (RPS2220AA) User Manual, Version A0. The maker labels this figure as the rated or continuous AC output of this model; surge, peak and boost figures are kept in their own fields. Recorded in kW from the printed watts.
Where: PDF page 20 (printed page 19), Specifications, Output, AC Output (x1/x2) row
222 WhChemistry Lithium Ion · Cycle life 500 cycles
Rated AC output
200 WSurge AC output 400 W
Solar input limit
60 W
Solar input voltage
10-25 V
Weight
2.4 kg / 5.3 lbDimensions 155 W × 170 H × 190 L mm / 6.1 W × 6.69 H × 7.48 L in
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · 120 V AC · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity500 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
FCC Part 15manufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RPS2220AA
Limitations
Renogy's PHOENIX 200 (RPS2220AA) user manual Version A0, captured on September 26, 2026, prints "This device complies with Part 15 of the FCC Rules." and a Class B digital device statement on printed page 20. No FCC ID is printed and no issuer record was read. Manufacturer claim only.
FCC Part 15Manufacturer claim · unresolved document setClaimedListed when checked
Renogy's PHOENIX 200 (RPS2220AA) user manual Version A0, captured on September 26, 2026, prints "This device complies with Part 15 of the FCC Rules." and a Class B digital device statement on printed page 20. No FCC ID is printed and no issuer record was read. Manufacturer claim only.
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Heading block, SKU line and description; Support Downloads links; product image
Retrieved Sep 26, 2026
Renogy's own support (download) page on renogy.com, captured on September 26, 2026; the current store listing captured the same day carries no product page for this model. It prints "SKU: RPS2220AA" and a short description ("5.3 pounds and a capacity of 222Wh"), links the user manual and shows the product image. It carries no revision date. Manufacturer claims, not independent tests.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Embedded manuals list: page_name, sku and manual file entries for the PHOENIX and Renogy power stations
Retrieved Sep 26, 2026
Renogy's own Manuals Center page, captured with the robots-checking fetch helper on September 26, 2026. Its embedded page data lists each portable power station's page name, SKU and user manual file; it is read for those names, SKUs and manual links only. It carries no revision date and establishes no specification. The same page was archived on September 25, 2026 as NP25-RENOGY-MANUALS; this capture replaces that copied file so every source in this manifest was fetched in this pass.
Renogy PHOENIX 200 Portable Power Station (RPS2220AA) User Manual, Version A0
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
RPS2220AA
Published model / SKU
PHOENIX 200
The product name Renogy prints with RPS2220AA in the manual's applicability statement; Renogy's Manuals Center lists it as "New PHOENIX 200 Portable Power Station".
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 500 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.