Charged ReviewsSaved 0Compare 0Login
PECRON
Portable power station

PECRON T3000

Key specs

Capacity2,963 Wh
AC output3,000 W
Weight30 kg / 66 lb converted
Cycle life1,000 cycles
Surge output6,000 W

1 spec not documented yet: usable capacityHelp fill in ›

All specifications

Identity

BrandPECRON · Website
ModelT3000
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: No manufacturer SKU is printed in the visible text of the sources read.
Sources: No source on record
FieldValueConditionsSource
Ports3 standard PURE SINE WAVE AC outlets; 2*USB-C; 1*Quick Charge 3.0 port; DC12V10A; DC48V50A
Ports as the page prints them; nothing is added.
Where: Product description; Specifications list, DC Output
[1]
ChemistryLithium-ion Check note
PECRON documents print different values. PECRON's T3000/T6000 user manual prints "Lithium-ion", which is recorded; the manual is the primary source. PECRON's earlier product page printed "Li-ion".
PECRON's T3000/T6000 user manual: The manual prints that the T6000/T3000 "is designed with the safe lithium-ion battery and inverter technology". Corrected on 17 October 2026: the catalog had recorded "Li-ion" from the archived product page; that value stays listed as an alternative. Revised on 17 October 2026: PECRON's live user manual prints a different value for this exact model; it is recorded, and the earlier value, which rested only on an Internet Archive copy, is kept as an alternative (PM, October 17, 2026).
Where: 1. Product introduction
Sources
Li-ion

Printed as "Battery: Li-ion(70%@1000Cycle)".

[1]
[2]
Weight30 kg / 66 lb converted
Printed as "Weight(kg) 30 43" in PECRON's T3000/T6000 user manual, technical specification table, Weight(kg) row, T3000 column. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, Weight(kg) row, T3000 column
[2]
Cycle life1,000 cycles
Printed as "Li-ion(70%@1000Cycle)"; to 70% of capacity. Depth of discharge, rate and temperature are not stated.
Where: Specifications list, Battery
[1]
AC output3,000 W
Printed as "AC Out Power 3000 W" in PECRON's T3000/T6000 user manual, technical specification table, AC Out Power row (one value for both models). Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, AC Out Power row (one value for both models)
[2]
Capacity57.2 Ah
Printed as "2963Wh(51.8V57.2Ah)" in PECRON's T3000/T6000 user manual, technical specification table, Battery capacity row, T3000 column. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, Battery capacity row, T3000 column
[2]
Capacity2,963 Wh
Printed as "2963Wh(51.8V57.2Ah)" in PECRON's T3000/T6000 user manual, technical specification table, Battery capacity row, T3000 column. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, Battery capacity row, T3000 column
[2]
DimensionsW 460 × H 250 × L 580 mm / W 18.1 × H 9.84 × L 22.8 in converted
Printed as "Dimension(cm) L58*W46*H25" in PECRON's T3000/T6000 user manual, technical specification table, Dimension(cm) row. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, Dimension(cm) row
[2]
Surge output6,000 W
Printed as "Peak Power 6000W"; duration not stated.
Where: Specifications list, Output Power
[1]
Nominal voltage51.8 V
Printed as "2963Wh(51.8V57.2Ah)" in PECRON's T3000/T6000 user manual, technical specification table, Battery capacity row, T3000 column. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, Battery capacity row, T3000 column
[2]
Rated capacity2.96 kWh
Converted: 2963 Wh / 1000 Wh per kWh
Printed as "2963Wh(51.8V57.2Ah)" in PECRON's T3000/T6000 user manual, technical specification table, Battery capacity row, T3000 column. 2963 Wh expressed in kWh. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, Battery capacity row, T3000 column
Sources
Converted: 2963 Wh / 1000 Wh per kWh
[2]
AC output voltage110 V
Printed as "AC Pure-Sine Wave 110V/60Hz" in PECRON's T3000/T6000 user manual, technical specification table, Output voltage row.
Where: PDF page 1, technical specification table, Output voltage row
[2]
Charge temperature0 to 45 °C / 32 to 113 °F converted
Printed as "0℃~45℃(Charge)" in PECRON's T3000/T6000 user manual, technical specification table, Temp row.
Where: PDF page 1, technical specification table, Temp row
[2]
Continuous output3 kW
Converted: 3000 W / 1000 W per kW
Printed as "AC Out Power 3000 W" in PECRON's T3000/T6000 user manual, technical specification table, AC Out Power row (one value for both models). 3000 W expressed in kW. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as PECRON's own document prints it (PM, October 17, 2026).
Where: PDF page 1, technical specification table, AC Out Power row (one value for both models)
Sources
Converted: 3000 W / 1000 W per kW
[2]
Discharge temperature-20 to 45 °C / -4 to 113 °F converted
Printed as "20℃~45℃(Discharge)" in PECRON's T3000/T6000 user manual, technical specification table, Temp row. The minus sign is printed as a dash character before 20℃.
Where: PDF page 1, technical specification table, Temp row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Battery capacity
2,963 WhChemistry Lithium-ion · Cycle life 1,000 cycles
Rated AC output
3,000 WSurge AC output 6,000 W
Solar input limit
Not stated
Solar input voltage
Not stated
Weight
30 kg / 66 lbDimensions 460 W × 250 H × 580 L mm / 18.1 W × 9.84 H × 22.8 L in

Evidence score

4/100Missing details20% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

Power stations · Output unconfirmed · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Lifetime / capacity1,000 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

[1]

Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • PECRON T3000/T6000 User Manual, portable power station (no revision printed)Official · PECRON · Official user manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-01.

    Location: PDF page 1, T3000/T6000 User Manual technical specification table

    Retrieved Oct 1, 2026

    PECRON's own user manual for the T3000 and T6000, linked as the T series user manual from PECRON's user manual page in 2021 and 2022 (archived copies) and still served from PECRON's store file host, where it was captured 1 October 2026. It is a single long PDF page; no revision or date is printed. Its technical specification table has one column for each model. Manufacturer instructions, not independent tests.

    Archived copies

    Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.63 MB

    Archived copy, unaltered, kept as a record of what PECRON published. Original address: https://cdn.shopify.com/s/files/1/0509/5263/4556/files/T_series_user_manul.pdf?v=1613983439. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    1

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 6a1683fa2af749fd655de53f4e40c700ecb3b02f589ab66a7f69914c85a0ba66

    Open
  • Other documents

  • PECRON T3000 product page, archived copy (Wayback Machine, March 2, 2021)PECRON · Source product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Product Details: Features, WARRANTY, Specifications list, Product Description; product media

    Retrieved Sep 26, 2026

    Archived copy of PECRON's page as of March 2, 2021, served by the Internet Archive's Wayback Machine and captured on September 26, 2026. It shows what PECRON's own store printed for the T3000 on that date, not what PECRON prints now; PECRON's current US storefront listing (September 26, 2026) does not list the T3000. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

PECRON T3000/T6000 User Manual, portable power station (no revision printed)

Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.63 MB

Archived copy, unaltered, kept as a record of what PECRON published. Original address: https://cdn.shopify.com/s/files/1/0509/5263/4556/files/T_series_user_manul.pdf?v=1613983439. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
1

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6a1683fa2af749fd655de53f4e40c700ecb3b02f589ab66a7f69914c85a0ba66

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
T3000

Manufacturer SKU unknown

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 1,000 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [1]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. PECRON T3000 product page, archived copy (Wayback Machine, March 2, 2021) (PECRON · archive · observed Sep 26, 2026)
  2. PECRON T3000/T6000 User Manual, portable power station (no revision printed) (PECRON · manufacturer · observed Oct 1, 2026)

Sign in to report an error on this page

Similar products

All with a price