Common specifications
| Rated capacity | 3.07 kWhCalculatedSource [1] |
|---|---|
| Usable capacity | Not documented |
| Battery voltage | 51.2 VSource [1] |
| Rated capacity | 60 AhSource [1] |
| Continuous output | 3.6 kWCalculatedSource [1] |
| AC output voltage | 120 VSource [1] |
| Maximum AC charging | Not documented |
| PV input limit | 1.6 kWCalculatedSource [1] |
| Transfer time | Not documented |
| Continuous discharge current | Not documented |
| Continuous charge current | Not documented |
| Peak discharge current | Not documented |
| Timed peak output | Not documented |
| Dimensions | |
| Weight | |
| Communications | Not documented |
| Terminals | Not documented |
| Enclosure | Not documented |
| Chemistry | LiFePO4Source [1] |
| Cycle life | 3,500 cyclesSource [1] |
| Solar input voltage | 25 to 120 VSource [4] |
| MPPT voltage range | Not documented |
| Maximum PV voltage | 120 VSource [4] |
| AC charge input | 1,800 WSource [1] |
| Enclosure volume | 40.68 L** Calculated from recorded external dimensions |
| Warranty term | 2 yearsSource [6, 7] |
All recorded specifications
| AC charge input | 1,800 WDocumented claim ConditionsPrinted as "120Vac, 50/60Hz, 1800W Max, 15A Max"; the manual prints 1500 W at 100 Vac and 1650 W at 110 Vac. Manufacturer claim. Location: SPECIFICATIONS, INPUT SPECIFICATION, AC INLET Printed as "120Vac, 50/60Hz, 1800W Max, 15A Max"; the manual prints 1500 W at 100 Vac and 1650 W at 110 Vac. Manufacturer claim. Location: SPECIFICATIONS, INPUT SPECIFICATION, AC INLET |
|---|---|
| AC output voltage | 120 VDocumented claim ConditionsUS AC output. AC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Manual filename V2-20260310 conflicts with printed EN-V1.4; retain both and do not invent date. US AC output. AC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Manual filename V2-20260310 conflicts with printed EN-V1.4; retain both and do not invent date. |
| Battery capacity | 3,072 WhDocumented claim ConditionsPublished as "3072Wh" for the base unit; expansion batteries are sold separately. Location: Product page title Published as "3072Wh" for the base unit; expansion batteries are sold separately. Location: Product page title |
| Battery format | Power stationSite classificationCharged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim. Based onOfficial instruction manual · PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310 [1] |
| Battery voltage | 51.2 VDocumented claim ConditionsAC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table AC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table |
| Charging temperature | 0 to 45 °C32 to 113 °F convertedDocumented claim ConditionsPrinted as "Charging Ambient Temperature 0℃ ~ 45℃ / 32℉ ~ 113℉". Manufacturer claim. Location: SPECIFICATIONS, OPERATING TEMPERATURE Printed as "Charging Ambient Temperature 0℃ ~ 45℃ / 32℉ ~ 113℉". Manufacturer claim. Location: SPECIFICATIONS, OPERATING TEMPERATURE |
| Chemistry | LiFePO4Documented claim ConditionsLocation: PDF page 3, specification table Location: PDF page 3, specification table |
| Continuous output | 3.6 kWCalculated3600 W x 0.001 = 3.6 kW ConditionsPrinted as "120V - 3600W Max" in PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310, PECRON F3000LFP user manual, SPECIFICATIONS, AC OUTPUT row. Revised on 1 October 2026: The PECRON user manual prints 3600 W; 3.6 kW is the same figure in kilowatts. Location: PECRON F3000LFP user manual, SPECIFICATIONS, AC OUTPUT row Printed as "120V - 3600W Max" in PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310, PECRON F3000LFP user manual, SPECIFICATIONS, AC OUTPUT row. Revised on 1 October 2026: The PECRON user manual prints 3600 W; 3.6 kW is the same figure in kilowatts. Location: PECRON F3000LFP user manual, SPECIFICATIONS, AC OUTPUT row |
| Cycle life | 3,500 cyclesDocumented claim Conditions80% retained capacity. Other test conditions not established. Location: PDF page 3, specification table 80% retained capacity. Other test conditions not established. Location: PDF page 3, specification table |
| Dimensions | 295 W × 282 H × 489 L mm11.6 W × 11.1 H × 19.3 L in convertedDocumented claim ConditionsAC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table AC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table |
| Discharging temperature | -20 to 45 °C-4 to 113 °F convertedDocumented claim ConditionsPrinted as "Supply Ambient Temperature -20℃ ~ 45℃ / -4℉ ~ 113℉"; the manual labels the discharging condition "Supply". Manufacturer claim. Location: SPECIFICATIONS, OPERATING TEMPERATURE Printed as "Supply Ambient Temperature -20℃ ~ 45℃ / -4℉ ~ 113℉"; the manual labels the discharging condition "Supply". Manufacturer claim. Location: SPECIFICATIONS, OPERATING TEMPERATURE |
| Estimated throughput | Not documented ConditionsNot printed for this model in the documents on file. Revised on 1 October 2026: PECRON prints no lifetime energy figure; the stored value was computed from capacity and cycle life. Not printed for this model in the documents on file. Revised on 1 October 2026: PECRON prints no lifetime energy figure; the stored value was computed from capacity and cycle life. |
| Maximum PV voltage | 120 VDocumented claim ConditionsPrinted as "the total solar panels open-circuit voltage (Voc) must be less than 120V, and the operating voltage (Vmp) must be greater than 25V", for panels wired in series on the XT60 input; stated as a "less than" limit. Location: User manual p. 8, Using solar panels charging, step 4 Printed as "the total solar panels open-circuit voltage (Voc) must be less than 120V, and the operating voltage (Vmp) must be greater than 25V", for panels wired in series on the XT60 input; stated as a "less than" limit. Location: User manual p. 8, Using solar panels charging, step 4 |
| Ports | Output Volts: 100V~120V Pure Sine Wave; DC Output: 10A(12V)Documented claim ConditionsOutput ports exactly as the specification table lists them, in the order published. Location: Specification table, output port rows Output ports exactly as the specification table lists them, in the order published. Location: Specification table, output port rows |
| PV input limit | 1.6 kWCalculated1600 W x 0.001 = 1.6 kW ConditionsPrinted as "25Vdc~120Vdc, 1600W Max, 25A Max" in PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310, PECRON F3000LFP user manual, SPECIFICATIONS, XT60 input row. Revised on 1 October 2026: The PECRON user manual prints 1600 W; 1.6 kW is the same figure in kilowatts. Location: PECRON F3000LFP user manual, SPECIFICATIONS, XT60 input row Printed as "25Vdc~120Vdc, 1600W Max, 25A Max" in PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310, PECRON F3000LFP user manual, SPECIFICATIONS, XT60 input row. Revised on 1 October 2026: The PECRON user manual prints 1600 W; 1.6 kW is the same figure in kilowatts. Location: PECRON F3000LFP user manual, SPECIFICATIONS, XT60 input row |
| Rated AC output | 3,600 WDocumented claim ConditionsPublished as "3600W"; the page does not state the test temperature or power factor. Location: Product page title Published as "3600W"; the page does not state the test temperature or power factor. Location: Product page title |
| Rated capacity | 60 AhDocumented claim ConditionsAC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table AC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table |
| Rated capacity | 3.07 kWhCalculated3072 Wh x 0.001 = 3.072 kWh ConditionsPrinted as "Capacity 3072Wh(51.2V60Ah)" in PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310, PECRON F3000LFP user manual, SPECIFICATIONS, GENERAL INFO, Capacity row. Revised on 1 October 2026: The PECRON user manual prints 3072 Wh; 3.072 kWh is the same figure in kilowatt-hours. Location: PECRON F3000LFP user manual, SPECIFICATIONS, GENERAL INFO, Capacity row Printed as "Capacity 3072Wh(51.2V60Ah)" in PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310, PECRON F3000LFP user manual, SPECIFICATIONS, GENERAL INFO, Capacity row. Revised on 1 October 2026: The PECRON user manual prints 3072 Wh; 3.072 kWh is the same figure in kilowatt-hours. Location: PECRON F3000LFP user manual, SPECIFICATIONS, GENERAL INFO, Capacity row |
| Solar input limit | 1,600 WDocumented claim ConditionsPrinted as "Solar Input XT60: 25Vdc~120Vdc; 1600W Max; 25A Max" on the F3000LFP product page, captured on September 25, 2026. Location: Product page, Specs table, Solar Input row Printed as "Solar Input XT60: 25Vdc~120Vdc; 1600W Max; 25A Max" on the F3000LFP product page, captured on September 25, 2026. Location: Product page, Specs table, Solar Input row |
| Solar input voltage | 25 to 120 VDocumented claim ConditionsPrinted as "XT60 interface supports input voltage range of 25Vdc~120Vdc, maximum input power of 1600W, maximum current of 25A". The FAQ says there is one built-in MPPT controller and the "XT60" port supports 25~120V (Max 1600W) PV input; the range is not labelled as an MPPT operating range. Manufacturer claim, not an independent test. Location: User manual p. 8, Using solar panels charging, step 4; FAQ 6 p. 11 Printed as "XT60 interface supports input voltage range of 25Vdc~120Vdc, maximum input power of 1600W, maximum current of 25A". The FAQ says there is one built-in MPPT controller and the "XT60" port supports 25~120V (Max 1600W) PV input; the range is not labelled as an MPPT operating range. Manufacturer claim, not an independent test. Location: User manual p. 8, Using solar panels charging, step 4; FAQ 6 p. 11 |
| Storage temperature | -20 to 45 °C-4 to 113 °F convertedDocumented claim ConditionsPrinted as "Storage Ambient Temperature -20℃ ~ 45℃ / -4℉ ~ 113℉ (Optimal Range: 20℃ ~ 30℃ / 68℉ ~ 86℉)". Location: SPECIFICATIONS, OPERATING TEMPERATURE Printed as "Storage Ambient Temperature -20℃ ~ 45℃ / -4℉ ~ 113℉ (Optimal Range: 20℃ ~ 30℃ / 68℉ ~ 86℉)". Location: SPECIFICATIONS, OPERATING TEMPERATURE |
| Weight | 28.7 kg63.3 lb convertedDocumented claim ConditionsAC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table AC 3600 W only at 120 V (3000 W at 100 V, 3300 W at 110 V); PV 25–120 V, 25 A. Location: PDF page 3, specification table |
Warranty
| Warranty term | 2 yearsDocumented claimPlus 3 years after registration ConditionsPrinted as "2+3 Years Warranty!" on the F3000LFP product page, captured on September 25, 2026. PECRON's warranty registration page states that the additional term is activated by registering within 30 days of purchase ("E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years."), so the first figure is recorded as the term without registration. Location: Product page, headline feature list and Specs table Printed as "2+3 Years Warranty!" on the F3000LFP product page, captured on September 25, 2026. PECRON's warranty registration page states that the additional term is activated by registering within 30 days of purchase ("E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years."), so the first figure is recorded as the term without registration. Location: Product page, headline feature list and Specs table Official warranty · PECRON warranty registration page (September 25, 2026 capture)Official product page · PECRON F3000LFP product page (September 25, 2026 capture) [6, 7] |
|---|---|
| Optional warranty extension | 3 years further, only if the product is registered with PECRON within 30 days of purchaseDocumented claim ConditionsThe product page prints "2+3 Years Warranty!"; the registration page prints "E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years." and limits the extension to brand new portable power stations bought from PECRON's own channel. Location: WARRANTY REGISTRATION introduction The product page prints "2+3 Years Warranty!"; the registration page prints "E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years." and limits the extension to brand new portable power stations bought from PECRON's own channel. Location: WARRANTY REGISTRATION introduction Official warranty · PECRON warranty registration page (September 25, 2026 capture)Official product page · PECRON F3000LFP product page (September 25, 2026 capture) [6, 7] |
Certificate records
No records documented.
Sources and revisions
- PECRON manual PECRON_F3000_LFP_user_manual_100V_120V_V2 20260310Official instruction manual · Revision F3000 LFP-EN-V1.4 · Checked https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_F3000_LFP_user_manual_100V_120V_V2-20260310.pdf?v=1777365085
- PECRON f3000lfpOfficial product page · Checked https://www.pecron.com/products/pecron-f3000lfp-portable-power-station-3600w-3072wh
- PECRON F3000LFP product pageOfficial product page · Checked https://pecron.com/products/pecron-f3000lfp-portable-power-station-3600w-3072wh
- PECRON F3000LFP user manual (PDF)Official user manual · Checked https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_F3000_LFP_user_manual_100V_120V_V2-20260310.pdf
- PECRON power-station collection products.jsonOfficial product feed · Checked https://www.pecron.com/collections/power-station/products.json?limit=250
- PECRON F3000LFP product page (September 25, 2026 capture)Official product page · Checked https://www.pecron.com/products/pecron-f3000lfp-portable-power-station-3600w-3072wh
- PECRON warranty registration page (September 25, 2026 capture)Official warranty · Checked https://www.pecron.com/pages/warranty-registration
- PECRON store product data (products.json page 1, 2026-10-27 capture)Official product feed · Checked https://www.pecron.com/products.json?limit=250&page=1