Charged ReviewsSaved 0Compare 0Login
PECRON E500LFP Portable Power Station 600W 576Wh
PECRON
Portable power station

PECRON E500LFP Portable Power Station 600W 576Wh

Key specs

Capacity576 Wh
AC output600 W
Weight6.8 kg / 15 lb
Rated capacity0.576 kWh
Continuous output0.6 kW
Solar input100 W

1 spec not documented yet: usable capacityHelp fill in ›

All specifications

Identity

BrandPECRON · Website
ModelE500LFP
MarketUnknown
Manufacturer SKUE500LFP
SKU detail
locator: PECRON product data (products.json, page 1), listing "PECRON E500LFP Portable Power Station 600W 576Wh" (handle pecron-e500lfp-portable-power-station-600w-576wh), option "E500LFP", "sku":"E500LFP"
conditions: PECRON's own product data, captured 2026-10-27, prints SKU "E500LFP" for option "E500LFP" (variant 44050347360444) of listing "PECRON E500LFP Portable Power Station 600W 576Wh".
Sources: [1]
FieldValueConditionsSource
PortsOutput Volts: 100V~120V Pure Sine Wave; DC Output: 12V / 24V
Output ports exactly as the specification table lists them, in the order published.
Where: Specification table, output port rows
[2]
ChemistryLiFePo4 with 3,500+ Life Cycles to 80%
Cell chemistry exactly as the specification table names it; cell supplier and format are not published.
Where: Specification table, Battery Type
[2]
Weight6.8 kg / 15 lbNet weight of the unit as published ("15lbs(6.8Kg)").
Where: Specification table, Weight
[2]
AC input500 W
Printed as "AC 100V~120V Max 500W"; the manual adds that AC, 5521 DC and USB-C charging together are limited to 500W. Manufacturer claim.
Where: INPUT SPECS, AC INLET
[3]
Cycle life3,500 cycles
To 80% capacity
Printed as "LiFePO4 Battery Retain 80%+ Original Capacity At 3500 Cycles" in the E500LFP user manual (August 5, 2024 file), refetched on September 25, 2026. 80% retained capacity; the manual prints no depth of discharge, C-rate or temperature for this figure.
Where: User manual, SPECIFICATIONS table
[4]
AC output600 W
Published as "600W"; the page does not state the test temperature or power factor.
Where: Product page title
[2]
Capacity30 AhManufacturer published rating; not independently tested.
Where: PDF page 3, SPECIFICATIONS
[5]
Capacity576 Wh
Published as "600W 576Wh" in the product title on PECRON's E500LFP page, whose Specifications print "Capacity 576Wh". Manufacturer claims, not independent tests. Revised on 29 September 2026: The earlier note said expansion batteries are sold separately, which the maker does not print for this model.
Where: Product page title; Specifications, Capacity
[6]
DimensionsW 172 × H 189 × L 254 mm / W 6.77 × H 7.44 × L 10 in converted
Printed as "L10*W6.8*H7.4 in L254*W172*H189 mm" in the E500LFP user manual (August 5, 2024 file), refetched on September 25, 2026. The product page captured the same day prints "L252 x W170 x H187 MM".
Where: User manual, SPECIFICATIONS table, Dimension row
[4]
Solar input100 W
Printed as "Solar Input DC5521: Voc 12V~28V / 100W Max /7A Max" on the E500LFP product page, captured on September 25, 2026.
Where: Product page, Specs table, Solar Input row
[7]
Max PV voltage28 V
Printed as "The VOC of a single solar panel should be less than 28V, and the VMP should be greater than 12V." beside the illustration of charging the E500 LFP with one solar panel through the 5521 port; stated as a "less than" limit for a single panel.
Where: User manual p. 7, How to charge by solar panel
[4]
Transfer time20 ms
Printed as "the AC output will switch to supply power from the battery pack of the power station within 8~20ms"; an upper bound of a printed range, not a measured value.
Where: UPS FUNCTION
[3]
Nominal voltage19.2 VManufacturer published rating; not independently tested.
Where: PDF page 3, SPECIFICATIONS
[5]
Rated capacity0.576 kWhManufacturer published rating; not independently tested.
Where: PDF page 3, SPECIFICATIONS
[5]
PV input voltage12 to 28 V
Printed as "DC Charging (12V~28V) Max 100W 5521 *1" in the input specifications. The FAQ says there is one built-in MPPT controller and the "5521" port supports 12~28V (Max 100W) PV input; the range is not labelled as an MPPT operating range. Manufacturer claim, not an independent test.
Where: User manual p. 3, Input specs, DC charging (5521); FAQ Q5 p. 8
[4]
Charge temperature0 to 45 °C / 32 to 113 °F converted
Printed as "0℃~45℃/32°F~113°F(Charging)". Manufacturer claim.
Where: SPECIFICATIONS, Temperature
[3]
Continuous output0.6 kW
Manufacturer published rating; not independently tested.
Where: Product specifications table, continuous_output_kw
[8]
Storage temperature-20 to 45 °C / -4 to 113 °F converted
Printed as "-20℃~45℃/-4°F~113°F(Storage) Optimal storage temperature: 20℃ ~ 30℃ / 68℉ ~ 86℉".
Where: SPECIFICATIONS, Temperature
[3]
Discharge temperature-20 to 45 °C / -4 to 113 °F converted
Printed as "-20℃~45℃/-4°F~113°F(Discharging)". Manufacturer claim.
Where: SPECIFICATIONS, Temperature
[3]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Battery capacity
576 WhChemistry LiFePo4 with 3,500+ Life Cycles to 80% · Cycle life 3,500 cycles
Rated AC output
600 W
Solar input limit
100 W
Solar input voltage
12-28 VMax PV voltage 28 V
Weight
6.8 kg / 15 lbDimensions 172 W × 189 H × 254 L mm / 6.77 W × 7.44 H × 10 L in

Evidence score

4/100Missing details20% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

Power stations · Output unconfirmed · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Lifetime / capacity3,500 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

[4]

Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • PECRON E500LFP user manual (PDF)Official · PECRON · Official user manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Specifications and safety sections

    Retrieved Sep 19, 2026

    Manufacturer user manual PDF published for the PECRON E500LFP. It establishes the manufacturer documentation that ships with the model; it does not establish certification listings, seller pricing or current availability.

    Archived copies

    Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.60 MB

    Archived copy, unaltered, kept as a record of what PECRON published. Original address: https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_E500LFP_user_manual_100V_120V_-20240805_ded9107d-a64f-439d-bfe7-66471e6b7a88.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    None

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 4458e34d739bc4995b1bc23ccf3936a49a97972f78ac0c179dda9aebbf286732

    Open
  • Other documents

  • PECRON E500LFP product identityOfficial · PECRON · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Revision date not established.

    Location: Original source record

    Retrieved Sep 15, 2026

    Open

Archive and older revisions

Archive and older revisions4

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • PECRON E500LFP user manual, 100V to 120V (PDF dated 26-03-11 in its file name)Official · PECRON · Official user manual · March 11, 2026 · PDF
    Source details
    Revision
    Not stated
    Revision date
    March 11, 2026

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: SPECIFICATIONS; INPUT SPECS; UPS FUNCTION

    Retrieved Sep 26, 2026

    PECRON's own current user manual for the E500 LFP, linked as "E500LFP User Manual" from PECRON's user manual page and archived on September 26, 2026. It is a newer file than the August 2024 manual the record already cites. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.83 MB

    Archived copy, unaltered, kept as a record of what PECRON published. Original address: https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_E500LFP_user_manual_100V_120V_-260311.pdf?v=1781171483. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    12

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: ee0ef78a1db82d4be075d21589c76a54d63011177304cd09711f5b830116f59b

    Open
  • PECRON E500LFP product page (September 29, 2026 capture)Official · PECRON · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-09-29.

    Location: Product page title, specifications and FAQ

    Retrieved Sep 29, 2026

    PECRON product page as served on September 29, 2026. It establishes the figures and statements printed on it on that date; it does not establish certification, third-party test results, price or availability.

    Open
  • PECRON E500LFP product page (September 25, 2026 capture)Official · PECRON · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Headline feature list; Specs table

    Retrieved Sep 24, 2026

    PECRON's own US store page for the E500LFP, captured on September 25, 2026. Cited only for the rows quoted from its headline feature list and specification table; store-wide template text on the page (for example a generic warranty line in the "Why Choose Us" block) is not read as a product specification.

    Open
  • PECRON E500LFP product pageOfficial · PECRON · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Product page title

    Retrieved Sep 19, 2026

    Manufacturer marketing and specification page for the PECRON E500LFP. It establishes the model designation and the figures printed in its specification table on the date read; it does not establish certification, third-party test results, price or availability.

    Open

Archived documents

PECRON user manual

Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.60 MB

Archived copy, unaltered, kept as a record of what PECRON published. Original address: https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_E500LFP_user_manual_100V_120V_-20240805_ded9107d-a64f-439d-bfe7-66471e6b7a88.pdf?v=1723097108. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
11

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 4458e34d739bc4995b1bc23ccf3936a49a97972f78ac0c179dda9aebbf286732

PECRON E500LFP user manual, 100V to 120V (PDF dated 26-03-11 in its file name)

Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.83 MB

Archived copy, unaltered, kept as a record of what PECRON published. Original address: https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_E500LFP_user_manual_100V_120V_-260311.pdf?v=1781171483. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
12

Embedded dates are file metadata, not independent proof of publication.

SHA-256: ee0ef78a1db82d4be075d21589c76a54d63011177304cd09711f5b830116f59b

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
E500LFP

Manufacturer SKU E500LFP

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 3,500 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [4]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. PECRON store product data (products.json page 1, 2026-10-27 capture) (PECRON · manufacturer · observed Oct 27, 2026)
  2. PECRON E500LFP product page (PECRON · manufacturer · observed Sep 19, 2026)
  3. PECRON E500LFP user manual, 100V to 120V (PDF dated 26-03-11 in its file name) (PECRON · manufacturer · observed Sep 26, 2026)
  4. PECRON E500LFP user manual (PDF) (PECRON · manufacturer · observed Sep 19, 2026)
  5. PECRON user manual (PECRON · manufacturer · observed Sep 15, 2026)
  6. PECRON E500LFP product page (September 29, 2026 capture) (PECRON · manufacturer · observed Sep 29, 2026)
  7. PECRON E500LFP product page (September 25, 2026 capture) (PECRON · manufacturer · observed Sep 24, 2026)
  8. PECRON E500LFP product identity (PECRON · manufacturer · observed Sep 15, 2026)

Sign in to report an error on this page

Similar products

All with a price