Charged Reviews

Quick reference

PECRON E3600LFP

Model: E3600LFP · SKU: E3600LFP

Prepared Nov 12, 2026

Common specifications

Rated capacity
3.07 kWhCalculatedSource [1]
Usable capacityNot documented
Battery voltage
51.2 VSource [1]
Rated capacity
60 AhSource [1]
Continuous output
3.6 kWCalculatedSource [1]
AC output voltage
120 VSource [1]
Maximum AC chargingNot documented
PV input limit
2.4 kWCalculatedSource [1]
Transfer time
20 msSource [1]
Continuous discharge currentNot documented
Continuous charge currentNot documented
Peak discharge currentNot documented
Timed peak outputNot documented
Dimensions
307 W × 350 H × 445 L mm12.1 W × 13.8 H × 17.5 L in convertedSource [1]
Weight
36 kg79 lb convertedSource [1]
CommunicationsNot documented
TerminalsNot documented
EnclosureNot documented
Chemistry
LiFePO4Source [1]
Cycle life
3,500 cyclesSource [1]
Solar input voltageNot documented
MPPT voltage range
XT60-M charging port: 32-150 V; DC5521 charging port: 12-30 VSource [4]
Maximum PV voltage
XT60-M charging port: 150 V; DC5521 charging port: 30 VSource [4]
AC charge input
3,200 WSource [1]
Enclosure volume47.82 L** Calculated from recorded external dimensions
Warranty term
2 yearsSource [6, 7]

All recorded specifications

AC charge input
3,200 WDocumented claim
Conditions

Printed as "AC INPUT 100Vac~120Vac 50/60HZ 3200W Max (Charging cable with 30A)"; the figure applies with the 30 A charging cable. Manufacturer claim.

Location: HOW TO USE THE E3600 LFP, AC INPUT

Printed as "AC INPUT 100Vac~120Vac 50/60HZ 3200W Max (Charging cable with 30A)"; the figure applies with the 30 A charging cable. Manufacturer claim.

Location: HOW TO USE THE E3600 LFP, AC INPUT

[1]
AC output voltage
120 VDocumented claim
Conditions

US AC output. Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

US AC output. Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

[1]
Battery capacity
3,072 WhDocumented claim
Conditions

Published as "3072Wh" for the base unit; expansion batteries are sold separately.

Location: Product page title

Published as "3072Wh" for the base unit; expansion batteries are sold separately.

Location: Product page title

[3]
Battery format
Power stationSite classificationCharged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.[1]
Battery voltage
51.2 VDocumented claim
Conditions

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

[1]
Charging temperature
0 to 45 °C32 to 113 °F convertedDocumented claim
Conditions

Printed as "0℃~45℃/32°F~113°F (Charging)" (Temperature); ambient range in which the manual says the unit charges. Manufacturer claim, not an independent test.

Location: SPECIFICATIONS, GENERAL INFO, Temperature

Printed as "0℃~45℃/32°F~113°F (Charging)" (Temperature); ambient range in which the manual says the unit charges. Manufacturer claim, not an independent test.

Location: SPECIFICATIONS, GENERAL INFO, Temperature

[1]
Chemistry
LiFePO4Documented claim
Conditions

Location: PDF page 3, specification table

Location: PDF page 3, specification table

[1]
Continuous output
3.6 kWCalculated3600 W x 0.001 = 3.6 kW
Conditions

Printed as "Pure sine wave 100V~120V Rated 3600W Max" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, AC OUTPUT row. Revised on 1 October 2026: The PECRON user manual prints 3600 W; 3.6 kW is the same figure in kilowatts.

Location: PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, AC OUTPUT row

Printed as "Pure sine wave 100V~120V Rated 3600W Max" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, AC OUTPUT row. Revised on 1 October 2026: The PECRON user manual prints 3600 W; 3.6 kW is the same figure in kilowatts.

Location: PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, AC OUTPUT row

[1]
Cycle life
3,500 cyclesDocumented claim
Conditions

Printed as "LiFePO4 (3500+Cycles to 80%)" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PDF page 3, specification table, Battery Type. Revised on 1 October 2026: The manual prints "3500+Cycles to 80%", a lower bound the stored number does not show.

Location: PDF page 3, specification table, Battery Type

Printed as "LiFePO4 (3500+Cycles to 80%)" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PDF page 3, specification table, Battery Type. Revised on 1 October 2026: The manual prints "3500+Cycles to 80%", a lower bound the stored number does not show.

Location: PDF page 3, specification table, Battery Type

[1]
Dimensions
307 W × 350 H × 445 L mm12.1 W × 13.8 H × 17.5 L in convertedDocumented claim
Conditions

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

[1]
Discharging temperature
-20 to 45 °C-4 to 113 °F convertedDocumented claim
Conditions

Printed as "-20℃~45℃/-4°F~113°F (Discharging)"; ambient range in which the manual says the unit discharges. Manufacturer claim, not an independent test.

Location: SPECIFICATIONS, GENERAL INFO, Temperature

Printed as "-20℃~45℃/-4°F~113°F (Discharging)"; ambient range in which the manual says the unit discharges. Manufacturer claim, not an independent test.

Location: SPECIFICATIONS, GENERAL INFO, Temperature

[1]
Estimated throughput
Not documented
Conditions

Not printed for this model in the documents on file. Revised on 1 October 2026: PECRON prints no lifetime energy figure; the stored value was computed from capacity and cycle life.

Not printed for this model in the documents on file. Revised on 1 October 2026: PECRON prints no lifetime energy figure; the stored value was computed from capacity and cycle life.

[1]
Maximum PV voltage
XT60-M charging port: 150 V; DC5521 charging port: 30 VDocumented claim
Conditions

Printed as "VOC(open circuit voltage) of solar panel/array must be less than 150V, otherwise, it will damage the unit!" for the XT60-M port and "VOC(open circuit voltage) of solar panel must be less than 30V" for the DC5521 port; both are stated as "less than" limits. The June 28, 2024 manual prints "less than 25V" for the DC5521 port.

Location: User manual p. 12, Using solar panels to charge the E3600 LFP

Printed as "VOC(open circuit voltage) of solar panel/array must be less than 150V, otherwise, it will damage the unit!" for the XT60-M port and "VOC(open circuit voltage) of solar panel must be less than 30V" for the DC5521 port; both are stated as "less than" limits. The June 28, 2024 manual prints "less than 25V" for the DC5521 port.

Location: User manual p. 12, Using solar panels to charge the E3600 LFP

[4]
MPPT voltage range
XT60-M charging port: 32-150 V; DC5521 charging port: 12-30 VDocumented claim
Conditions

Printed as "XT60-M Charging Port: PV(operating voltage) range 32V~150V, 2400W maximum" and "DC5521 Charging Port: PV/DC 12V~30V, 150W maximum". The FAQ describes two independent 1200W (PV 32V-150V) MPPT charge controllers and one step-up 150W (PV 12V~30V) MPPT charge controller. The DC5521 range is labelled PV/DC rather than operating voltage. Manufacturer claim, not an independent test.

Location: User manual p. 12, Using solar panels to charge the E3600 LFP; FAQ Q7 p. 17

Printed as "XT60-M Charging Port: PV(operating voltage) range 32V~150V, 2400W maximum" and "DC5521 Charging Port: PV/DC 12V~30V, 150W maximum". The FAQ describes two independent 1200W (PV 32V-150V) MPPT charge controllers and one step-up 150W (PV 12V~30V) MPPT charge controller. The DC5521 range is labelled PV/DC rather than operating voltage. Manufacturer claim, not an independent test.

Location: User manual p. 12, Using solar panels to charge the E3600 LFP; FAQ Q7 p. 17

[4]
Ports
AC Output: Single E3600LFP 3600W 120V;; DC 12V Output: 12V/30A Max; USB-C Output: 5V, 9V, 12V, 20V/100W;; USB-A Output: 5V, 9V, 12V/ 18W Max*4; Wireless Charging Output: 15W Max*2Documented claim
Conditions

Output ports exactly as the specification table lists them, in the order published.

Location: Specification table, output port rows

Output ports exactly as the specification table lists them, in the order published.

Location: Specification table, output port rows

[3]
PV input limit
2.4 kWCalculated2400 W x 0.001 = 2.4 kW
Conditions

Printed as "PV(operating voltage) range 32V~150V, 2400W maximum" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PECRON E3600LFP user manual, solar charging section, XT60-M Charging Port. Revised on 1 October 2026: The PECRON user manual prints 2400 W; 2.4 kW is the same figure in kilowatts.

Location: PECRON E3600LFP user manual, solar charging section, XT60-M Charging Port

Printed as "PV(operating voltage) range 32V~150V, 2400W maximum" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PECRON E3600LFP user manual, solar charging section, XT60-M Charging Port. Revised on 1 October 2026: The PECRON user manual prints 2400 W; 2.4 kW is the same figure in kilowatts.

Location: PECRON E3600LFP user manual, solar charging section, XT60-M Charging Port

[1]
Rated AC output
3,600 WDocumented claim
Conditions

Published as "3600W"; the page does not state the test temperature or power factor.

Location: Product page title

Published as "3600W"; the page does not state the test temperature or power factor.

Location: Product page title

[3]
Rated capacity
60 AhDocumented claim
Conditions

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

[1]
Rated capacity
3.07 kWhCalculated3072 Wh x 0.001 = 3.072 kWh
Conditions

Printed as "Capacity 3072Wh(51.2V60Ah)" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, GENERAL INFO, Capacity row. Revised on 1 October 2026: The PECRON user manual prints 3072 Wh; 3.072 kWh is the same figure in kilowatt-hours.

Location: PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, GENERAL INFO, Capacity row

Printed as "Capacity 3072Wh(51.2V60Ah)" in PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628, PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, GENERAL INFO, Capacity row. Revised on 1 October 2026: The PECRON user manual prints 3072 Wh; 3.072 kWh is the same figure in kilowatt-hours.

Location: PECRON E3600LFP user manual, PDF page 3, SPECIFICATIONS, GENERAL INFO, Capacity row

[1]
Solar input limit
2,400 WDocumented claim
Conditions

Printed as "2400W Solar Charging Max (2*1200W XT60 port 32V-150V/20A Max)" on the E3600LFP product page, captured on September 25, 2026. Two XT60 solar ports; the DC5521 port is printed separately at 150 W.

Location: Product page, Specs table, Solar Input row

Printed as "2400W Solar Charging Max (2*1200W XT60 port 32V-150V/20A Max)" on the E3600LFP product page, captured on September 25, 2026. Two XT60 solar ports; the DC5521 port is printed separately at 150 W.

Location: Product page, Specs table, Solar Input row

[6]
Transfer time
20 msDocumented claim
Conditions

Printed as "near-instantaneous(within 8~20ms)" for the E3600 LFP; an upper bound of a printed 8 to 20 ms range, not a measured value. The manual adds that it is not applicable to loads that need a transfer time under 8 ms. Manufacturer claim, not an independent test.

Location: UPS FUNCTION section

Printed as "near-instantaneous(within 8~20ms)" for the E3600 LFP; an upper bound of a printed 8 to 20 ms range, not a measured value. The manual adds that it is not applicable to loads that need a transfer time under 8 ms. Manufacturer claim, not an independent test.

Location: UPS FUNCTION section

[1]
Weight
36 kg79 lb convertedDocumented claim
Conditions

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

Two PV ports, each 32–150 V, 20 A, 1200 W. 240 V requires two stations and separate connection kit.

Location: PDF page 3, specification table

[1]

Warranty

Warranty term
2 yearsDocumented claimPlus 3 years after registration
Conditions

Printed as "Warranty: 2+3 Years" on the E3600LFP product page, captured on September 25, 2026. PECRON's warranty registration page states that the additional term is activated by registering within 30 days of purchase ("E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years."), so the first figure is recorded as the term without registration.

Location: Product page, headline feature list and Specs table

Printed as "Warranty: 2+3 Years" on the E3600LFP product page, captured on September 25, 2026. PECRON's warranty registration page states that the additional term is activated by registering within 30 days of purchase ("E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years."), so the first figure is recorded as the term without registration.

Location: Product page, headline feature list and Specs table

[6, 7]
Optional warranty extension
3 years further, only if the product is registered with PECRON within 30 days of purchaseDocumented claim
Conditions

The product page prints "Warranty: 2+3 Years"; the registration page prints "E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years." and limits the extension to brand new portable power stations bought from PECRON's own channel.

Location: WARRANTY REGISTRATION introduction

The product page prints "Warranty: 2+3 Years"; the registration page prints "E1500LFP E3600LFP F1000LFP F3000LFP are extra 3 years." and limits the extension to brand new portable power stations bought from PECRON's own channel.

Location: WARRANTY REGISTRATION introduction

[6, 7]

Certificate records

No records documented.

Sources and revisions

  1. PECRON manual PECRON_E3600LFP_user_manual_100V_120V_ 20240628Official instruction manual · Checked https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_E3600LFP_user_manual_100V_120V_-20240628.pdf?v=1721185695
  2. PECRON e3600lfpOfficial product page · Checked https://www.pecron.com/products/pecron-e3600lfp-portable-power-station-3600w-3072wh
  3. PECRON E3600LFP product pageOfficial product page · Checked https://pecron.com/products/pecron-e3600lfp-portable-power-station-3600w-3072wh
  4. PECRON E3600LFP user manual (PDF)Official user manual · Checked https://cdn.shopify.com/s/files/1/0509/5263/4556/files/PECRON_E3600LFP_user_manual_100V_120V_-20251016.pdf
  5. PECRON power-station collection products.jsonOfficial product feed · Checked https://www.pecron.com/collections/power-station/products.json?limit=250
  6. PECRON E3600LFP product page (September 25, 2026 capture)Official product page · Checked https://www.pecron.com/products/pecron-e3600lfp-portable-power-station-3600w-3072wh
  7. PECRON warranty registration page (September 25, 2026 capture)Official warranty · Checked https://www.pecron.com/pages/warranty-registration
  8. PECRON store product data (products.json page 1, 2026-10-27 capture)Official product feed · Checked https://www.pecron.com/products.json?limit=250&page=1