conditions: No manufacturer SKU is printed in the manual read; PECRON's storefront SKU "E1500LFP" is used for its current V3 listing (record pecron-e1500lfp-v3), so it is not applied to this earlier version.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Ports
AC Out *3 (Pure sine wave 100V~120V Rated 2200W); USB-A *4 (5V,9V,12V, Max 18W)*4; USB-C *2 (5V,9V,12V, Max 18W)*1 (5V,9V,12V,20V, Max 100W)*1; Cigar Port *1 DC 12V-10A; XT60 Output *1 DC 12V-30A; DC 5525 Output *1 DC 12V-5A; Wireless Charger *1 Max 15W
Output ports as the manual lists them, rearranged by table row; nothing is added.
Printed as "DC Charging (32V~95V) Max 700W Max 15A" for the GX16MF port. A second port, "DC Charging (12V~18V) Max 100W Max 7A", is listed separately; the manual does not say whether both can be used at once, so no combined figure is recorded. Manufacturer claim, not an independent test.
Printed as "near-instantaneous(within 8~20ms)" for the E1500 LFP; an upper bound of a printed 8 to 20 ms range, not a measured value. The manual adds that it is not applicable to loads that need a transfer time under 8 ms. Manufacturer claim, not an independent test.
Printed as "0℃~45℃/32°F~113°F (Charging)" (Temperature); ambient range in which the manual says the unit charges. Manufacturer claim, not an independent test.
Printed as "-20℃~45℃/-4°F~113°F (Discharging)"; ambient range in which the manual says the unit discharges. Manufacturer claim, not an independent test.
1,536 WhChemistry LiFePO4 · Cycle life 3,500 cycles
Rated AC output
2,200 W
Solar input limit
700 W
Solar input voltage
32-95 V
Weight
18.5 kg / 40.8 lbDimensions 237 W × 305 H × 377 L mm / 9.33 W × 12 H × 14.8 L in
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity3,500 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Location: Pages 1 to 15, 100V~120V English edition; page 3, 1536Wh (51.2V30Ah)
Retrieved Oct 28, 2026
PECRON's own E1500LFP user manual, served from its store's file host; an earlier edition than the 2025-07-01 manual already on this record. One file holds several editions: the 100V~120V English section (pages 1 to 15) applies to this US record; later sections are the 220V-240V European-plug English, Japanese and Chinese editions and do not apply to it. It prints E1500 / E1500 LFP, not V3. The 2023-06-28 date comes from the file name, not a printed issue date. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: PDF page 3, SPECIFICATIONS; PDF pages 5 and 6
Retrieved Sep 26, 2026
PECRON's own user manual for an E1500 LFP version with a 32V~95V 700W solar input and a 1400W AC input, still hosted on PECRON's Shopify file store and archived on September 26, 2026. The document prints no version label; PECRON's current page and the V3 manual describe a different version (11V~60V 1000W solar input). Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
PECRON E1500LFP user manual, 100V to 120V (PDF dated 2025-07-01 in its file name)
Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
PECRON E1500LFP user manual, earlier multi-edition file (dated 2023-06-28 in its file name)
Archived copy of a document published by PECRON. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
E1500LFP
Manufacturer SKU unknown · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 3,500 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.