Charged ReviewsSaved 0Compare 0Login
OUPES Exodus 2400
Photo 1 of 2Photo 2 of 2
OUPES
Portable power station

OUPES Exodus 2400

Key specs

Capacity2,232 Wh
AC output2,400 W
Weight20.5 kg / 45.2 lb converted
Solar input800 W
Cycle life3,500 cycles
Surge output4,500 W

1 spec not documented yet: usable capacityHelp fill in ›

All specifications

Identity

BrandOUPES · Website
ModelExodus 2400
MarketUS
Manufacturer SKUPW-EXODUS 2400
SKU detail
locator: products[].variants[].sku, first variant of handle oupes-exodus-2400-portable-power-station-2400w-2232wh
conditions: OUPES's own ordering SKU for the power station alone, printed as "sku":"PW-EXODUS 2400" in the oupes.com storefront listing captured on September 25, 2026. The other variants of the same listing are kits with solar panels or extra batteries.
Sources: [1]
FieldValueConditionsSource
PortsAC Outlets: 4*NEMA 5-20R (120V/20A); USB-A Output: 4*USB-A (18W Max); USB-C Output: 2*USB-C (140W per port); 12V DC Output: 2*DC 5521 (12V/10A) 1*Car Lighter (12V/10A)
Output ports exactly as the specifications column lists them, in the order printed.
Where: Specs, Exodus 2400 column, OUTPUT rows
[2]
ChemistryLiFePO4Printed as "Type LFP (LiFePO4)".
Where: Specs, Exodus 2400 column, BATTERY, Type
[2]
Weight20.5 kg / 45.2 lb converted
Net weight of the unit printed as "Net Weight 45.2lbs (20.5 kg)". The page body also prints "at just 45 lbs." (shown as an alternative).
Where: Specs, Exodus 2400 column, GENERAL, Net Weight
Sources
45 lb

Printed as "25% lighter than standard power stations, at just 45 lbs."; the page prints no kilogram figure there. The Specs column prints "Net Weight 45.2lbs (20.5 kg)".

[2]
[2]
Cycle life3,500 cycles
> 3500 cycles as printed
Printed as "> 3500 cycles to 80%"; test rate, depth of discharge and temperature are not stated.
Where: Specs, Exodus 2400 column, BATTERY, Cycles
[2]
AC output2,400 W
Printed as "AC Output Power 2400W (2600W Boost Mode, 4500W Surge)"; rated AC output.
Where: Specs, Exodus 2400 column, OUTPUT, AC Output Power
[2]
Capacity2,232 Wh
Printed as "Basic Capacity 2232Wh" for the unit alone.
Where: Specs, Exodus 2400 column, BATTERY, Basic Capacity
[2]
DimensionsW 270 × H 310 × L 457 mm / W 10.6 × H 12.2 × L 18 in converted
Printed as "17.9 x 10.6 x 12.2in (457.0 x 270.0 x 310.0mm)"; the millimeter figures are recorded, with D recorded as height in the printed order. Clearances are not stated.
Where: Specs, Exodus 2400 column, GENERAL, Dimensions (L x W x D)
[2]
Solar input800 W
Printed as "Solar Charging 800W Max, 12-78V DC MPPT: 16-70V, 13A Max"; manufacturer claim, not an independent test.
Where: Specs, Exodus 2400 column, INPUT, Solar Charging
[2]
MPPT voltage16 to 70 V
Printed as "Solar Charging 800W Max, 12-78V DC MPPT: 16-70V, 13A Max" in the Exodus 2400 specifications table; the MPPT range is the part labeled "MPPT". Manufacturer claim, not an independent test.
Where: Specs, Exodus 2400 column, INPUT, Solar Charging
[2]
Surge output4,500 W
Printed as "AC Output Power 2400W (2600W Boost Mode, 4500W Surge)"; the surge duration is not stated. The 2600W Boost Mode figure is not a surge rating and is not recorded here.
Where: Specs, Exodus 2400 column, OUTPUT, AC Output Power
[2]
Enclosure ratingIP21
Printed as "IP Grade IP21" in the power station's own column; the 240W solar panel column on the same page prints IP65, which is not used.
Where: Specs, Exodus 2400 column, GENERAL, IP Grade
[2]
Maximum AC charging1.4 kW
Converted: 1400 W / 1000 W per kW
Printed as "Fast AC Charging 1400W Max"; 1400 W expressed in kW. The column also prints "Slow AC Charging 700W" and "AC + Solar Charging 2200W Max".
Where: Specs, Exodus 2400 column, INPUT, Fast AC Charging
Sources
Converted: 1400 W / 1000 W per kW
[2]
Transfer time20 ms
< 20ms as printed
Printed as "UPS/EPS < 20ms"; an upper bound (less than 20 ms), not a measured value.
Where: Specs, Exodus 2400 column, BATTERY, UPS/EPS
[2]
Rated capacity2.23 kWh
Converted: 2232 Wh / 1000 Wh per kWh
Printed as "Basic Capacity 2232Wh"; 2232 Wh expressed in kWh.
Where: Specs, Exodus 2400 column, BATTERY, Basic Capacity
Sources
Converted: 2232 Wh / 1000 Wh per kWh
[2]
PV input voltage12 to 78 V
Printed as "Solar Charging 800W Max, 12-78V DC MPPT: 16-70V, 13A Max" in the Exodus 2400 specifications table; this is the DC input range printed before the MPPT range, for the solar input. Manufacturer claim, not an independent test.
Where: Specs, Exodus 2400 column, INPUT, Solar Charging
[2]
AC output voltage120 VPrinted as "4*NEMA 5-20R (120V/20A)".
Where: Specs, Exodus 2400 column, OUTPUT, AC Outlets
[2]
Continuous output2.4 kW
Converted: 2400 W / 1000 W per kW
Printed as "AC Output Power 2400W (2600W Boost Mode, 4500W Surge)"; 2400 W expressed in kW.
Where: Specs, Exodus 2400 column, OUTPUT, AC Output Power
Sources
Converted: 2400 W / 1000 W per kW
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Battery capacity
2,232 WhChemistry LiFePO4 · Cycle life 3,500 cycles
Rated AC output
2,400 WSurge AC output 4,500 W
Solar input limit
800 W
Solar input voltage
12-78 V
Weight
20.5 kg / 45.2 lbDimensions 270 W × 310 H × 457 L mm / 10.6 W × 12.2 H × 18 L in

Evidence score

14/100Missing details40% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

Power stations · 120 V AC · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Warranty term5 years10 / 20

5 years · 20% weight

5 of 10 years, the best documented for a power station (printed by the maker): Briggs & Stratton PowerBank 5.4 battery powered generator (5.4 kWh, 1,600 W)

Printed as "Up to 6 Years (Basic 5 years warranty. Register for 1 Extra Year Free!)"; the basic term is 5 years. Coverage, eligibility and remedies are set by the OUPES warranty policy, which was not read.

50 / 100 × 20 = 10 points.

[2]

Lifetime / capacity3,500 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

[2]

Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
MSDSmanufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
Exodus 2400
Limitations
OUPES's Exodus 2400 product page prints "Certification UN38.3; MSDS" in the power station's own specifications column, captured on September 25, 2026. MSDS is a safety data document, not a product safety certification. No test summary, report number, laboratory or date is printed, and no issuer record was read. Manufacturer claim only.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UN38.3manufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
Exodus 2400
Limitations
OUPES's Exodus 2400 product page prints "Certification UN38.3; MSDS" in the power station's own specifications column, captured on September 25, 2026. UN38.3 is a transport test for lithium batteries. No test summary, report number, laboratory or date is printed, and no issuer record was read. Manufacturer claim only.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]

Warranty

FieldValueConditionsSource
Warranty term5 years
Printed as "Up to 6 Years (Basic 5 years warranty. Register for 1 Extra Year Free!)"; the basic term is 5 years. Coverage, eligibility and remedies are set by the OUPES warranty policy, which was not read.
Where: Specs, Exodus 2400 column, GENERAL, Warranty
[2]
Extended warranty1 further year, only if the product is registered
Printed as "Up to 6 Years (Basic 5 years warranty. Register for 1 Extra Year Free!)".
Where: Specs, Exodus 2400 column, GENERAL, Warranty
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Other documents

  • OUPES Exodus 2400 product page (September 25, 2026 capture)Official · OUPES · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Specs tab, Exodus 2400 column; product media gallery

    Retrieved Sep 25, 2026

    OUPES's own US product page for the Exodus 2400, captured on September 25, 2026; the content is whatever the address served on that date and may change without notice. The page carries no revision date. The Specs tab prints separate columns for the Exodus 2400 and for the 240W solar panel; only the Exodus 2400 column is cited.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

OUPES Exodus 2400 User Manual (PDF linked from the product page)

Archived copy of a document published by OUPES. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 13.23 MB

Archived copy, unaltered, kept as a record of what OUPES published. Original address: https://cdn.shopify.com/s/files/1/0599/0137/8737/files/Exodus_2400_user_manual.pdf?v=1741655529. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
65

Embedded dates are file metadata, not independent proof of publication.

SHA-256: c42cf122d91d086e06644f82dc2dc86c7280fe3dc57f7ae01766c49a54d7f62d

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Exodus 2400

Manufacturer SKU PW-EXODUS 2400 · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: UN38.3 · MSDS
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: 5
unit: years
shown: 5 years
shown detail: Unknown
state: documented
points: 10
ceiling: 20
weight: 20
share: 50
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 3,500 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [2]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. OUPES storefront product listing, products.json (September 25, 2026 capture) (OUPES · manufacturer · observed Sep 25, 2026)
  2. OUPES Exodus 2400 product page (September 25, 2026 capture) (OUPES · manufacturer · observed Sep 25, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details