Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: OSCAL PowerMax 2400 (US)Portable power station
OSCAL PowerMax 2400
Key specs
1 spec not documented yet: usable capacityHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Ports | AC output (×4) 2400W in total; Wireless charging (×2) 15W; USB-A 5V 2.4A 12W; USB-A fast charging (×3) 18W each; USB-C fast charging (×2) 100W each; Vehicle charging output 12/24V 10A 240W; DC5521 (×2) 12V 6A 72W; Anderson port 12/24V 10A 240W | As printed in the manual table (rendered page image). Where: PDF page 8, Parameter Specifications (image), Output Specifications | [2] |
| Chemistry | LFP (LiFePO4) | Printed as "Cell material LFP (LiFePO4)" (rendered page image). Where: PDF page 8, Parameter Specifications (image), Cell material | [2] |
| Weight | 25.5 kg / 56.2 lb converted | Printed as "Approx. 25.5kg (6.3kg+19.2kg)" (rendered page image). Where: PDF page 8, Parameter Specifications (image), Net weight | [2] |
| AC input | 1,400 W | Printed as "Max power 1400W" with "100-120V~15A, 210-240V~10A, 50Hz/60Hz" (rendered page image). Where: PDF page 8, Parameter Specifications (image), AC input power | [2] |
| Cycle life | 3,500 cycles | Printed as "More than 80% capacity remaining after 3500 cycles" (rendered page image). Where: PDF page 8, Parameter Specifications (image), Cycle life | [2] |
| AC output | 2,400 W | The manual prints "Pure sine wave, 2400W in total, 120V~, 230V~(50/60Hz)"; the store title prints "2400W(Surge 4800W)". Where: PDF page 8, Parameter Specifications (image), AC output (×4) | [2] [1] |
| Capacity | 1,872 Wh | The manual prints "Capacity 1872Wh" (read from the rendered page image); OSCAL's store title prints "1872Wh". Where: PDF page 8, Parameter Specifications (image), Capacity | [2] [1] |
| Dimensions | W 290 × H 302 × L 530 mm / W 11.4 × H 11.9 × L 20.9 in converted | Printed as "530×290×302mm" (rendered page image). Where: PDF page 8, Parameter Specifications (image), Dimensions (L×W×H) | [2] |
| Solar input | 800 W plus a second 300W input | Printed as "10-60V, max current 20A, max power 800W"; the DC7909 input prints "DC/Solar charging: 10-60V, rated power 300W, max current 10A" and AC+Solar+DC7909 "Max power 1500W" (rendered page image). Where: PDF page 8, Parameter Specifications (image), Solar charging input | [2] |
| Surge output | 4,800 W | Printed in the title as "Surge 4800W"; duration not stated. Where: Store product title | [1] |
| Maximum AC charging | 1.4 kWConverted: 1400 W / 1000 W/kW | Printed as "Max power 1400W"; expressed in kW. Where: PDF page 8, Parameter Specifications (image), AC input power SourcesConverted: 1400 W / 1000 W/kW | [2] |
| Max PV current | 20 A | Printed as "max current 20A". Where: PDF page 8, Parameter Specifications (image), Solar charging input | [2] |
| Transfer time | 10 ms | Printed as "the Product can automatically switch to its battery-powered mode within 10ms"; the manual adds it is not a professional UPS function (rendered page image). Where: PDF page 10, UPS Function (image) | [2] |
| Cycle life eol | 80 % | Printed as "More than 80% capacity remaining after 3500 cycles" in the same maker document as the recorded cycle life (PDF page 8); the page is an image without a text layer, so the value was read from the rendered page. The cycle life ends at 80% of capacity as printed. Where: PDF page 8 | [2] |
| Rated capacity | 1.87 kWhConverted: 1872 Wh / 1000 Wh/kWh | "1872Wh" expressed in kWh. Where: Store product title SourcesConverted: 1872 Wh / 1000 Wh/kWh | [1] |
| PV input voltage | 10 to 60 V | Printed as "10-60V"; not labeled as MPPT or open-circuit range. Where: PDF page 8, Parameter Specifications (image), Solar charging input | [2] |
| AC output voltage | 120V~ | Printed as "120V~, 230V~(50/60Hz)"; this record is the US Standard unit (store SKU PowerMax2400-US). Where: PDF page 8, Parameter Specifications (image), AC output (×4) | [2] |
| Continuous output | 2.4 kWConverted: 2400 W / 1000 W/kW | "2400W" expressed in kW. Where: Store product title SourcesConverted: 2400 W / 1000 W/kW | [1] |
| Wireless communications | Wi-Fi and Bluetooth | Printed as WIFI and Bluetooth rows, each "Frequency range: 2400-2483.5MHz Maximum output power: 20dBm" (rendered page image). Where: PDF page 8, Parameter Specifications (image), WIFI and Bluetooth rows | [2] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Battery capacity
- 1,872 WhChemistry LFP (LiFePO4) · Cycle life 3,500 cycles
- Rated AC output
- 2,400 WSurge AC output 4,800 W
- Solar input limit
- 800 W
- Solar input voltage
- 10-60 V
- Weight
- 25.5 kg / 56.2 lbDimensions 290 W × 302 H × 530 L mm / 11.4 W × 11.9 H × 20.9 L in
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
20 × 0.2 = 4 points.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
Unknown: no certification evidence recorded in this data.
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- PowerMax 2400
Manufacturer SKU PowerMax2400-US · US market
No historical observations recorded yet.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: 0.21-personal documented pct: 20 basis: nominal missing: Certificates evidence needed Warranty term needed Warranty energy disclosure evidence needed Cell model disclosure evidence needed criteria: key: certificateEvidence label: Certificates value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations. display note: Unknown Sources: No source on record key: years label: Warranty term value: Unknown unit: years shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: throughputEvidence label: Warranty energy disclosure value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment. display note: Unknown Sources: No source on record key: lifetime label: Lifetime / capacity value: Unknown unit: MWh/kWh shown: 3,500 cycles shown detail: Unknown state: documented points: 4 ceiling: 20 weight: 20 share: Unknown covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh. display note: Unknown Sources: [2] key: cellDisclosure label: Cell model disclosure value: 0 unit: disclosure points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 5 weight: 5 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- OSCAL Store product listing, products.json (September 26, 2026 capture) (OSCAL · manufacturer · observed Sep 26, 2026)
- OSCAL PowerMax 2400 user manual (file PowerMax2400 User Manual-2025120403203265.pdf) (OSCAL · manufacturer · observed Sep 26, 2026)
Sign in to report an error on this page
Similar products
All with a priceACOPOWER BP2000 Solar Generator
ACOPOWER IP-3526 Portable Industrial Power Station
ACOPOWER P1000 PLUS Portable Power Station
* Missing details