About brandMARSTEK (MARSTEK ENERGY CO., LIMITED) sells plug-in balcony batteries, residential energy storage systems, portable power stations, solar generators and power banks through its own online store at marstekenergy.com.
SKU detail
conditions: No manufacturer SKU is printed on the sources read.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Ports
2 AC; 2 USB-A 18W; USB-C #1 100W; USB-C #2 45W; DC5525 120W (12V/10A); car charger 120W (12V/10A); AC input; XT60 PV input; external battery port
Rendered PDF page 2 prints "Output" as "AC*2 ... USB-A*2 18W Max. (5V~12V) ... USB-C #1 100W Max. ... USB-C #2 45W Max. ... DC5525 120W(12V/10A) ... Car Charger 120W(12V/10A)".
Where: PDF page 2, SPECIFICATIONS table, Output row
Printed as "6000+ Cycles to 80% Capacity" in the same maker document as the recorded cycle life (PDF page 2); the page is an image without a text layer, so the value was read from the rendered page. The cycle life ends at 80% of capacity as printed.
From the EU edition of the manual. MARSTEK's M1200 user manual is the EU edition; the edition sold in this record's market (United States) may differ.
Printed as "PD100W" and "PD45W" in MARSTEK's M1200 user manual, Specifications table, Type-C Output cell. The cell lists two USB-C ports, port 1 rated PD 100 W and port 2 rated PD 45 W.
Where: PDF page 6, Specifications table, Type-C Output cell
From the EU edition of the manual. MARSTEK's M1200 user manual is the EU edition; the edition sold in this record's market (United States) may differ.
Printed as "can be charged within a temperature range of 0°C to 40°C" in MARSTEK's M1200 user manual, Operating temperature range paragraph and Specifications table, Charging Temperature cell.
Where: PDF page 6, Operating temperature range paragraph and Specifications table, Charging Temperature cell
From the EU edition of the manual. MARSTEK's M1200 user manual is the EU edition; the edition sold in this record's market (United States) may differ.
Printed as "-10 - 40℃" in MARSTEK's M1200 user manual, Specifications table, Operation Temperature cell. The table text layer lists the three temperature cells after their labels; the Operation Temperature cell was matched on the rendered page 6.
Where: PDF page 6, Specifications table, Operation Temperature cell
1,030 WhChemistry LiFePO₄ · Cycle life 6,000 cycles
Rated AC output
1,200 W
Solar input limit
800 W
Solar input voltage
12-59 V
Weight
13 kg / 29 lbDimensions 195 W × 200 H × 400 L mm / 7.68 W × 7.87 H × 15.7 L in
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity6,000 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Specifications table and Use Instructions
Retrieved Sep 26, 2026
MARSTEK's M1200 portable power station user manual, linked from MARSTEK's Download Center and served from its Shopify file store, captured on September 26, 2026. The manual states it "is for the energy storage system product with an AC output range of 200V-240V/50Hz" and shows Global, UK and Australian socket versions. Its specification table extracts with values after labels, so only contiguous runs are quoted. No revision or date is printed. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by MARSTEK. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: SPECIFICATIONS page
Retrieved Sep 26, 2026
MARSTEK's M1200 datasheet for the US market (file name "MARSTEK_M1200_US_EN.pdf"), linked from MARSTEK's Download Center and captured on September 26, 2026. Its text is drawn as outlines with no text layer, so it was rendered page by page (pdf.js, .cache/gen/tools/render.mjs) and read visually; every figure cites the PDF page and quotes the printed cell in its conditions. Manufacturer claims, not independent tests; no revision date is printed.
Archived copies
Archived copy of a document published by MARSTEK. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
MARSTEK M1200 datasheet, US English edition (PDF)
Archived copy of a document published by MARSTEK. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
MARSTEK M1200 portable power station user manual (PDF)
Archived copy of a document published by MARSTEK. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
M1200
Manufacturer SKU unknown · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 6,000 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.