Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: GRECELL's first image for its listing "【UK】GRECELL Portable Power Station 500W" (SKU DYCNX0001AGE-MXUK) in its own storefront data; the file is named DYCNX0001AGE-MXUK. The unit prints "T-500" on its front and shows two UK (BS 1363) AC sockets. Clean image, no overlay.Portable power station
GRECELL T-500
Key specs
1 spec not documented yet: usable capacityHelp fill in ›
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Chemistry | Lithium-ion Battery | Printed as "Battery Cell Type: Lithium-ion Battery". Where: UK 500W listing, SPECIFICATIONS | [1] |
| Weight | 6.4 kg / 14 lb converted | Printed as "Weight: 14.11 lb / 6.4 kg". Where: UK 500W listing, SPECIFICATIONS | [1] |
| AC output | 500 W | Printed as "AC Output ×2: Pure Sine Wave, 230V~50Hz, Total 500W". Where: UK 500W listing, SPECIFICATIONS | [1] |
| Capacity | 23.4 Ah Check note | From the US edition of the manual. GRECELL's T-500 user manual is the US edition; the edition sold in this record's market (United Kingdom) may differ. Read from rendered page 5: GRECELL's T-500 user manual, General Specifications table, Battery, Standard Capacity of Batteries row, printed as "22.2V, 23.4 Ah 519.48Wh". The page has no text layer.Where: PDF page 5, General Specifications table, Battery, Standard Capacity of Batteries row | [2] |
| Capacity | 519 Wh | Printed as "Battery Capacity: 519Wh / 140400mAh / 22.2V". Where: UK 500W listing, SPECIFICATIONS | [1] |
| Dimensions | W 202 × H 202 × L 294 mm / W 7.95 × H 7.95 × L 11.6 in converted | Printed as "294*202*202mm"; axes not labeled. Where: UK 500W listing, SPECIFICATIONS | [1] |
| Solar input | 105 W Check note | From the US edition of the manual. GRECELL's T-500 user manual is the US edition; the edition sold in this record's market (United Kingdom) may differ. Read from rendered page 5: GRECELL's T-500 user manual, General Specifications table, Input, Solar Charge Input row, printed as "12-26V, Max.105W". The page has no text layer.Where: PDF page 5, General Specifications table, Input, Solar Charge Input row | [2] |
| Nominal voltage | 22.2 V | Printed as "22.2V". Where: UK 500W listing, SPECIFICATIONS | [1] |
| Rated capacity | 0.52 kWhConverted: 519 Wh / 1000 Wh/kWh | Printed as "519Wh"; expressed in kWh. Where: UK 500W listing, SPECIFICATIONS SourcesConverted: 519 Wh / 1000 Wh/kWh | [1] |
| PV input voltage | 12 to 26 V | Printed as "PV Input: 12V~26V". Where: UK 500W listing, SPECIFICATIONS | [1] |
| USB c port power | 60 W Check note | From the US edition of the manual. GRECELL's T-500 user manual is the US edition; the edition sold in this record's market (United Kingdom) may differ. Read from rendered page 5: GRECELL's T-500 user manual, General Specifications table, Output, Type-C Output row, printed as "PD 60W". The page has no text layer.Where: PDF page 5, General Specifications table, Output, Type-C Output row | [2] |
| AC output voltage | 230V~50Hz | Printed as "230V~50Hz". Where: UK 500W listing, SPECIFICATIONS | [1] |
| Charge temperature | 0 to 40 °C / 32 to 104 °F converted | Printed as "Recharging Temperature: 32 to 104℉ (0 to 40℃)". Where: UK 500W listing, SPECIFICATIONS | [1] |
| Continuous output | 0.5 kWConverted: 500 W / 1000 W/kW | Printed as "500W"; expressed in kW. Where: UK 500W listing, SPECIFICATIONS SourcesConverted: 500 W / 1000 W/kW | [1] |
| Storage temperature | -20 to 45 °C / -4 to 113 °F converted Check note | From the US edition of the manual. GRECELL's T-500 user manual is the US edition; the edition sold in this record's market (United Kingdom) may differ. Read from rendered page 5: GRECELL's T-500 user manual, General Specifications table, Battery, Storage Temp row, printed as "-4 to 113°F (-20 to 45°C)". The page has no text layer.Where: PDF page 5, General Specifications table, Battery, Storage Temp row | [2] |
| Operating temperature | -10 to 40 °C / 14 to 104 °F converted Check note | From the US edition of the manual. GRECELL's T-500 user manual is the US edition; the edition sold in this record's market (United Kingdom) may differ. Read from rendered page 5: GRECELL's T-500 user manual, General Specifications table, Battery, Operating Temp row, printed as "14 to 104°F (-10 to 40°C)". The page has no text layer.Where: PDF page 5, General Specifications table, Battery, Operating Temp row | [2] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Battery capacity
- 519 WhChemistry Lithium-ion Battery
- Rated AC output
- 500 W
- Solar input limit
- 105 W
- Solar input voltage
- 12-26 V
- Weight
- 6.4 kg / 14 lbDimensions 202 W × 202 H × 294 L mm / 7.95 W × 7.95 H × 11.6 L in
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity0 / 20
No qualifying figure · 20% weight
Not published. No lifetime-production bonus.
Not documented. Undisclosed data scores 0.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
Unknown: no certification evidence recorded in this data.
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- T-500
Manufacturer SKU DYCNX0001AGE-MXUK · UK market
No historical observations recorded yet.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: 0.21-personal documented pct: 0 basis: nominal missing: Certificates evidence needed Warranty term needed Warranty energy disclosure evidence needed Lifetime / capacity evidence needed Cell model disclosure evidence needed criteria: key: certificateEvidence label: Certificates value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations. display note: Unknown Sources: No source on record key: years label: Warranty term value: Unknown unit: years shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: throughputEvidence label: Warranty energy disclosure value: 0 unit: evidence points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment. display note: Unknown Sources: No source on record key: lifetime label: Lifetime / capacity value: Unknown unit: MWh/kWh shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 20 weight: 20 share: Unknown covered: no missing: yes folded: no reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not published. No lifetime-production bonus. display note: Unknown Sources: [1] key: cellDisclosure label: Cell model disclosure value: 0 unit: disclosure points shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 5 weight: 5 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- GRECELL storefront product listing, products.json (September 26, 2026 capture) (GRECELL · manufacturer · observed Sep 26, 2026)
- GRECELL T-500 User Manual (PDF, file DYCNX0001AGEM-MXUS.pdf, image only, rendered) (GRECELL · manufacturer · observed Sep 26, 2026)
Sign in to report an error on this page
Similar products
All with a priceACOPOWER BP2000 Solar Generator
ACOPOWER IP-3526 Portable Industrial Power Station
ACOPOWER P1000 PLUS Portable Power Station
* Missing details