locator: Product data in the page markup, variant "F800 / Black"
conditions: FOSSiBOT's US ordering SKU for the black unit, carried in the archived US page's product data as "sku":"FOSSiBOT-F800-Black" (December 2, 2023 copy). It sits in the page markup, not in the visible text.
AC Outlets: 1 X AC Outlets; Type-C Port: 2 x PD20W, 1 x PD100W; USB-A Port: 2 x (QC3.0)18W; 12V DC Outlets: 1 x 12V/10A (Cigarette Lighter), 1 x 12V/10A (DC6530); inputs: AC Input, XT60 (solar and car)
Rows of the OUTPUT section as printed; the INPUT rows print "Car Input: 120W from XT60 port". The product summary says "8 Outputs for Charging Multiple Devices at once". The number of AC outlets is printed as "1 X AC Outlets"; the page shows no other count.
Where: Archived US page Tech Specs, OUTPUT and INPUT rows
Printed as "Battery type 40135 LiFePO4" in the manual. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Where: Manual PDF page 13, Battery Specification, Battery type row
Printed as "Product weight 6.5kg" in the manual. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
The manual prints "Use wall socket to get 400W fast charging". Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Printed as "LiFePO4 Battery with 3,500+ Life Cycles to 80%" and, in the FAQ, "F800 has more than 3500 cycles until 80%". Test C-rate, depth of discharge and temperature are not stated. The manual prints no cycle figure in its English section.
The manual prints "AC output, total share 800W" for the AC button and "AC output 800W 50Hz/60Hz, pure sine wave, 220V-240V" in the specifications table of its 220V-240V edition. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Printed as "Capacity 512Wh" in the manual Specifications table. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Where: Manual PDF page 13, Specifications, Capacity row
W 209 × H 230 × L 276 mm / W 8.23 × H 9.06 × L 10.9 in converted
Printed as "Product size L*W*H=276*209*230mm" in the manual. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Printed as "MPPT input 11.5-50V 8A 200W max" in the manual. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Not classified. The recorded text "40135 LiFePO4 cells, 3.2V 20Ah each" (Manual PDF page 13, Battery Specification) describes the battery cells, not the physical format of the product. None of the site's battery format codes clearly matches it, so the format is unknown until a source prints the product's physical format. Revised on 30 September 2026: The recorded value "40135 LiFePO4 cells, 3.2V 20Ah each" was printed text, not one of the site's battery format codes, and it describes the battery cells, not the physical format of the product. No site code clearly matches the printed wording, so the fact is set to unknown rather than guessed.
No source on record
MPPT voltage
11.5 to 50 V Check note
Manual and product page give different solar input voltage ranges. The F800 user manual prints "MPPT input 11.5-50V 8A 200W max"; the archived US product page FAQ prints "Work Voltage: 12-50V".
Printed as "MPPT input 11.5-50V 8A 200W max". The archived US page FAQ prints "Work Voltage: 12-50V" (shown as an alternative) and, in FAQ Q1, "112V-50V in voltage".
Where: Manual PDF page 13, Specifications, MPPT input row
Sources
12 to 50 V
Printed as "PV input requirements for F800: Work Voltage: 12-50V Current: under 8A". The manual prints "MPPT input 11.5-50V 8A 200W max".
Not expandable: the FAQ answers "Not, F800 is a single unit."
Printed as "Q7: Can I expand its capacity by connecting with battery? A: No." and "Q9: Does F800 support battery expansion? Not, F800 is a single unit."
Printed as "MPPT input 11.5-50V 8A 200W max" in the manual. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Printed as "Solar panels can have a maximum input of 200W and a maximum voltage of 50V."; the manual does not say whether 50 V is an open-circuit or operating figure.
Printed as "Battery pack rated voltage 25.6V" and "Battery pack output voltage 21V-29V" in the manual. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Where: Manual PDF page 13, Battery Specification, Battery pack rated voltage row
Printed as "Charging temperature 0~40°C" in the manual. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Where: Manual PDF page 13, Charging temperature row
Manual and product page give different storage temperature ranges. The F800 user manual prints "Recommended storage temperature: 32-104°F/0-45°C."; the archived US product page prints -10 to 45 °C in its Tech Specs panel and -15 to 40 °C in its FAQ.
Printed as "Recommended storage temperature: 32-104°F/0-45°C."; the Fahrenheit upper figure is printed as 104°F, which is 40°C, not 45°C. The Celsius range is recorded. The archived US page prints "Storage Temperature: 14-113℉ (-10-45℃)" in its Tech Specs panel and "Storage: -15-40℃ (-4-104℉)" in its FAQ (kept as alternatives).
Where: Manual PDF page 3, warning 25
Sources
-10 to 45 °C
Printed as "Storage Temperature: 14-113℉ (-10-45℃)".
Manual and product page give different operating temperature ranges. The F800 user manual prints "Operating temperature -10~40°C"; the archived US product page prints -20 to 40 °C in its Tech Specs panel and -15 to 40 °C for discharge in its FAQ.
Printed as "Operating temperature -10~40°C" in the manual, beside a separate charging range. The archived US page prints two other ranges, kept as alternatives: "Operating Temperature: -4-104℉ (-20-40℃)" in its Tech Specs panel and "Discharge: -15-40℃ (-4-104℉)" in its FAQ.
Where: Manual PDF page 13, Operating temperature row
Sources
-20 to 40 °C
Printed as "Operating Temperature: -4-104℉ (-20-40℃)"; -4℉ is -20℃ as printed.
6.5 kg / 14 lbDimensions 209 W × 230 H × 276 L mm / 8.23 W × 9.06 H × 10.9 L in
Evidence score
8/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "This product provides a 24-month warranty service from the date of purchase" in the manual; 24 months expressed in years. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
FOSSiBOT's US F800 page (Wayback Machine copy of December 2, 2023) prints, exactly: "Certifications: FCC, CE, PSE, RoHS, UN3 8.3, MSDS", captured on September 26, 2026. This row records the "CE" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F800 page (Wayback Machine copy of December 2, 2023) prints, exactly: "Certifications: FCC, CE, PSE, RoHS, UN3 8.3, MSDS", captured on September 26, 2026. This row records the "FCC" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F800 page (Wayback Machine copy of December 2, 2023) prints, exactly: "Certifications: FCC, CE, PSE, RoHS, UN3 8.3, MSDS", captured on September 26, 2026. This row records the "MSDS" entry as printed. MSDS is a safety data document, not a product safety certification. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F800 page (Wayback Machine copy of December 2, 2023) prints, exactly: "Certifications: FCC, CE, PSE, RoHS, UN3 8.3, MSDS", captured on September 26, 2026. This row records the "PSE" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F800 page (Wayback Machine copy of December 2, 2023) prints, exactly: "Certifications: FCC, CE, PSE, RoHS, UN3 8.3, MSDS", captured on September 26, 2026. This row records the "RoHS" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
UN3 8.3manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
F800
Limitations
FOSSiBOT's US F800 page (Wayback Machine copy of December 2, 2023) prints, exactly: "Certifications: FCC, CE, PSE, RoHS, UN3 8.3, MSDS", captured on September 26, 2026. This row records the "UN3 8.3" entry as printed. The page prints "UN3 8.3"; it is recorded as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
Printed as "This product provides a 24-month warranty service from the date of purchase" in the manual; 24 months expressed in years. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as FOSSiBOT's own document prints it (PM, October 17, 2026).
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: English section, PDF pages 1 to 15; Specifications and Battery Specification, PDF page 13; Warranty Card, PDF page 15
Retrieved Sep 26, 2026
The F800 user manual file linked from FOSSiBOT's archived US F800 page (December 2, 2023) under "FOSSIBOT F800 PORTABLE POWER STATION USER MANUAL" and still linked from FOSSiBOT's European User Guides page; captured from FOSSiBOT's Shopify file host on September 26, 2026. It is a multi-language manual; the English section is PDF pages 1 to 15. Its Specifications table (PDF page 13) prints a 220V-240V AC charging and AC output voltage, which is not the US edition's voltage; no voltage figure is taken from it for this US record. It prints no revision number or date. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by FOSSiBOT. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Product summary; Tech Specs panel (PREVIEW); FAQ; USER MANUAL link; product media gallery
Retrieved Sep 26, 2026
Archived copy of FOSSiBOT's US product page for the F800 (us.fossibot.com/products/fossibot-f800) as of December 2, 2023, served by the Internet Archive's Wayback Machine and captured on September 26, 2026. FOSSiBOT's current US store listing (September 26, 2026) no longer lists the F800 and the live address answers 404. Figures read from its Tech Specs panel, feature list and FAQ are FOSSiBOT's published figures on that date; manufacturer claims, not independent tests. The page and its FAQ do not always agree; each fact says which part it was read from. It links the user manual and carries no revision date.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
FOSSiBOT F800 Power Station User Manual (PDF linked from the archived US product page and from the FOSSiBOT EU User Guides page)
Archived copy of a document published by FOSSiBOT. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
F800
Manufacturer SKU FOSSiBOT-F800-Black · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: FCC · CE +4
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.