AC Outlets: 5 x AC, Rated Power 3,600W; USB-C Ports: 3 x PD20W, 1 x PD100W; USB-A Ports: 2 x QC3.0 18W; Cigarette Lighter: 1 x 12V/10A; XT-60 (RV Outlet): 1 x 12V/25A; DC 5521 (5.5mm Outlet): 2 x 12V/3A
Rows of the OUTPUT section as printed. The page's port list elsewhere prints "AC (4*3P)" and "1x NEMA TT-30 (120V)" separately; the panel does not say whether its five AC outlets include the TT-30.
Printed as "Lifecycle 6500+ Cycles to 50% Original Capacity"; the description prints "6500+ Cycles" without an end-of-life capacity. Test C-rate, depth of discharge and temperature are not stated.
Expandable with up to 2 FB3840 expansion batteries (F3600 Pro + 2 x FB3840 = 11,520Wh); third-party expansion batteries not supported; two F3600 Pro units cannot be connected together
Printed as "Scalability Expandable W/Up to 2 x FB3840", "F3600 Pro + 2*FB3840 = 11,520Wh", "Can I connect third-party expansion batteries to F3600 Pro? No" and "Can I connect two units of F3600 Pro together for more power No."
Where: Specifications panel, GENERAL, Scalability row; FAQ
The Certification row on FOSSiBOT's US F3600 Pro page lists FCC, CE, PSE, RoHS, UN38.3 and MSDS, captured September 25, 2026, without certificate numbers, standard numbers or issuers. The marks are recorded in the printed order and spelling.
Where: Specifications panel, GENERAL, Certification row
3,840 WhChemistry LiFePO4 · Cycle life 6,500 cycles
Rated AC output
3,600 WSurge AC output 7,200 W
Solar input limit
2,000 W
Solar input voltage
12-160 V
Weight
42 kg / 93 lbDimensions 321 W × 475.5 H × 609 L mm / 12.6 W × 18.72 H × 24 L in
Evidence score
14/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "5-year hassle-free warranty" and "5-Year Warranty Only at us.fossibot.com". The same page also prints "Warranty 2+3 Years" in its Specifications panel and does not say on what terms the two parts apply; no separate warranty policy was found on the US store.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
FOSSiBOT's US F3600 Pro page prints, exactly: "Certification FCC,CE,PSE,RoHS,UN38.3,MSDS", captured on September 25, 2026. This row records the "CE" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F3600 Pro page prints, exactly: "Certification FCC,CE,PSE,RoHS,UN38.3,MSDS", captured on September 25, 2026. This row records the "FCC" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F3600 Pro page prints, exactly: "Certification FCC,CE,PSE,RoHS,UN38.3,MSDS", captured on September 25, 2026. This row records the "MSDS" entry as printed. MSDS is a safety data document, not a product safety certification. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F3600 Pro page prints, exactly: "Certification FCC,CE,PSE,RoHS,UN38.3,MSDS", captured on September 25, 2026. This row records the "PSE" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F3600 Pro page prints, exactly: "Certification FCC,CE,PSE,RoHS,UN38.3,MSDS", captured on September 25, 2026. This row records the "RoHS" entry as printed. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
FOSSiBOT's US F3600 Pro page prints, exactly: "Certification FCC,CE,PSE,RoHS,UN38.3,MSDS", captured on September 25, 2026. This row records the "UN38.3" entry as printed. UN38.3 is a transport test for lithium batteries. No certificate number, test report, laboratory, certification body or date is printed beside it, and no issuer record was read. Manufacturer claim only.
Printed as "5-year hassle-free warranty" and "5-Year Warranty Only at us.fossibot.com". The same page also prints "Warranty 2+3 Years" in its Specifications panel and does not say on what terms the two parts apply; no separate warranty policy was found on the US store.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Whole document; not read for figures
Retrieved Sep 25, 2026
The user manual file that FOSSiBOT's US F3600 Pro product page links under "F3600 Pro Portable Power Station User Manual Download", captured on September 25, 2026. The PDF has no machine-readable text (its lettering is drawn as outlines), so no figure in the record was read from it and no printed string in it could be checked. It is listed as the manufacturer document the product page provides; its revision and date were not read.
Archived copies
Archived copy of a document published by FOSSiBOT. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
FOSSiBOT's own US product page for the F3600 Pro, captured on September 25, 2026. Every figure in the record is read from its Specifications panel, its product description or its FAQ, each located on the fact. The page carries no revision date, and its marketing sections and FAQ do not always agree with the Specifications panel; where the page prints two values for one fact, the panel value is recorded and the other is shown as an alternative on that fact. It links the user manual and publishes the product photographs.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
FOSSiBOT F3600 Pro Portable Power Station User Manual (PDF linked from the US product page)
Archived copy of a document published by FOSSiBOT. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
F3600 Pro
Manufacturer SKU USF3600-Pro · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: FCC · CE +4
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.