Charged ReviewsSaved 0Compare 0Login
EcoFlow RIVER Plus
EcoFlow
Portable power station

EcoFlow RIVER Plus

Key specs

Capacity360 Wh
AC output600 W
Weight5.4 kg / 12 lb converted
Solar input200 W
Cycle life800 cycles
Surge output1,200 W

1 spec not documented yet: usable capacityHelp fill in ›

All specifications

Identity

BrandEcoFlow · Website
ModelRIVER Plus
MarketUS
Manufacturer SKURIVER-Plus-US
SKU detail
locator: product.variants[].sku, "White" variant
conditions: EcoFlow's US store prints "sku":"RIVER-Plus-US" for the "White" variant of RIVER Plus. The "Black" variant carries SKU RIVER-Plus-B-US and, per the store, is incompatible with the RIVER Plus Extra Battery; it is noted here, not recorded as this record's SKU.
Sources: [1]
FieldValueConditionsSource
PortsAC Output (x3) /(x2 International Version) Full Sine Wave 600W (Surge 1200W) total; USB-A Output (x2) 5Vdc, 2.4A, 12W Max, per port; USB-A Fast Charge (x1) 5Vdc, 9Vdc, 12Vdc, 2.4A, 28W Max; USB-C Output (x1) 5Vdc, 9Vdc, 12Vdc, 15Vdc, 20Vdc, 5A, 100W Max; Car Power Output (x1) 136W, 13.6Vdc, 10A Max; DC5521 Output (x2) 13.6Vdc, 3A Max(per port)
Output rows as printed in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Outputs rows
[2]
ChemistryLithium-ion
Printed as "Cell Chemistry Lithium-ion" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Cell Chemistry row
[2]
Weight5.4 kg / 12 lb converted
Printed as "Net Weight 11.9 lbs (5.4kg)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Net Weight row
[2]
AC input330 W
Printed as "X-Stream Charge 330W Max" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, AC Charge Input Power row
[2]
Cycle life800 cycles
to 80%+ capacity
Printed as "Cycle Life 800 cycles to 80%+ capacity" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Cycle Life row
[2]
AC output600 W
Printed as "Full Sine Wave 600W (Surge 1200W) total, 120Vac" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, AC Output row
[2]
Capacity12.5 Ah
Printed as "Pack Capacity 360Wh (28.8V,12.5Ah)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Pack Capacity row
[2]
Capacity360 Wh
Printed as "Pack Capacity 360Wh (28.8V,12.5Ah)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Pack Capacity row
[2]
DimensionsW 185 × H 194 × L 288 mm / W 7.28 × H 7.64 × L 11.3 in converted
Printed as "Dimensions 11.3 x 7.3 x 7.7 in (28.8 x 18.5 x 19.4 cm)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications. The centimeter figures are recorded in millimeters, in the printed order.
Where: Technical Specifications, Dimensions row
[2]
Solar input200 W
Printed as "Solar Charge Input 200W, 10-25Vdc, 12A Max" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Solar Charge Input row
[2]
Surge output1,200 W
Printed as "Full Sine Wave 600W (Surge 1200W) total, 120Vac" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, AC Output row
[2]
Expansion notesWorks with the RIVER Plus Extra Battery; the Black RIVER Plus variant is incompatible with it.
The US store prints "*RIVER PLUS (Black) is incompatible with RIVER Plus Extra Battery"; the RIVER user manual FAQ prints "RIVER Plus Extra Battery, which is designed to be used with RIVER Plus only".
Where: Store description; RIVER user manual FAQ
[1] [3]
Max PV current12 A
Printed as "Solar Charge Input 200W, 10-25Vdc, 12A Max" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Solar Charge Input row
[2]
Transfer time30 ms
<30ms as printed
The manual says the RIVER Plus "will switch to provide power to the devices and appliances connected to it in <30ms" and calls this an "entry-level" grade UPS function that does not support 0ms switching. Recorded as the printed upper bound.
Where: Entry-Level UPS
[2]
Nominal voltage28.8 V
Printed as "Pack Capacity 360Wh (28.8V,12.5Ah)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Pack Capacity row
[2]
Rated capacity0.36 kWh
Converted: 360 Wh / 1000 Wh/kWh
Printed as "Pack Capacity 360Wh (28.8V,12.5Ah)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications. 360 Wh expressed in kWh.
Where: Technical Specifications, Pack Capacity row
Sources
Converted: 360 Wh / 1000 Wh/kWh
[2]
PV input voltage10 to 25 V
Printed as "Solar Charge Input 200W, 10-25Vdc, 12A Max" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications.
Where: Technical Specifications, Solar Charge Input row
[2]
AC output voltage120 V
Printed as "Full Sine Wave 600W (Surge 1200W) total, 120Vac" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications. The international version is printed as 230Vac.
Where: Technical Specifications, AC Output row
[2]
Charge temperature0 to 45 °C / 32 to 113 °F converted
Printed as "Charge Temperature* 32°F to 113°F (±5°F), 0 to 45°C (±3°C)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications. The tolerance (±3°C) is not part of the recorded range.
Where: Technical Specifications, Charge Temperature row
[2]
Continuous output0.6 kW
Converted: 600 W / 1000 W/kW
Printed as "Full Sine Wave 600W (Surge 1200W) total, 120Vac" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications. 600 W expressed in kW.
Where: Technical Specifications, AC Output row
Sources
Converted: 600 W / 1000 W/kW
[2]
Discharge temperature-20 to 60 °C / -4 to 140 °F converted
Printed as "Discharge Temperature* -4°F to 140°F (±5°F), -20°C to 60°C (±3°C)" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications. The tolerance (±3°C) is not part of the recorded range.
Where: Technical Specifications, Discharge Temperature row
[2]
Other compliance claimsUL Standard, CE, FCC, RoHS, RCM
Printed as "Testing and certification UL Standard, CE, FCC, RoHS, RCM" in the RIVER Plus user manual (Manuals+ copy), Technical Specifications. No standard number, certificate or file number is printed beside "UL Standard".
Where: Technical Specifications, Testing and certification row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Battery capacity
360 WhChemistry Lithium-ion · Cycle life 800 cycles
Rated AC output
600 WSurge AC output 1,200 W
Solar input limit
200 W
Solar input voltage
10-25 V
Weight
5.4 kg / 12 lbDimensions 185 W × 194 H × 288 L mm / 7.28 W × 7.64 H × 11.3 L in

Evidence score

4/100Missing details20% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

Power stations · 120 V AC · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

Lifetime / capacity800 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

[2]

Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CEmanufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RIVER Plus
Limitations
The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "CE" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
FCCmanufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RIVER Plus
Limitations
The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "FCC" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
RCMmanufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RIVER Plus
Limitations
The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "RCM" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
RoHSmanufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RIVER Plus
Limitations
The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "RoHS" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UL Standardmanufacturer claimpresent at observation[2]
Scope
unresolved document set
Covered models
RIVER Plus
Limitations
The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "UL Standard" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • EcoFlow RIVER Plus user manual, copy hosted by Manuals+ (September 26, 2026 capture)EcoFlow · Source user manual · Web page
    Certificate & compliance claims (5)
    UL StandardManufacturer claim · unresolved document setClaimedListed when checked

    The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "UL Standard" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.

    Manufacturer document

    Source user manual: EcoFlow RIVER Plus user manual, copy hosted by Manuals+ (September 26, 2026 capture)
    FCCManufacturer claim · unresolved document setClaimedListed when checked

    The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "FCC" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.

    Manufacturer document

    Source user manual: EcoFlow RIVER Plus user manual, copy hosted by Manuals+ (September 26, 2026 capture)
    CEManufacturer claim · unresolved document setClaimedListed when checked

    The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "CE" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.

    Manufacturer document

    Source user manual: EcoFlow RIVER Plus user manual, copy hosted by Manuals+ (September 26, 2026 capture)
    RoHSManufacturer claim · unresolved document setClaimedListed when checked

    The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "RoHS" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.

    Manufacturer document

    Source user manual: EcoFlow RIVER Plus user manual, copy hosted by Manuals+ (September 26, 2026 capture)
    RCMManufacturer claim · unresolved document setClaimedListed when checked

    The RIVER Plus user manual (Manuals+ copy of EcoFlow's text), Technical Specifications, prints, exactly: "Testing and certification UL Standard, CE, FCC, RoHS, RCM". This row records "RCM" as printed. No standard number, certificate number, certification body or file number is printed beside it, and no issuer record was read.

    Manufacturer document

    Source user manual: EcoFlow RIVER Plus user manual, copy hosted by Manuals+ (September 26, 2026 capture)
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Technical Specifications; Entry-Level UPS

    Retrieved Sep 26, 2026

    The EcoFlow RIVER Plus user manual, a copy of EcoFlow's user manual republished as a web page by Manuals+ (manuals.plus), a third-party manual host, captured on September 26, 2026. EcoFlow no longer lists the product on its US download center or manuals site, and no EcoFlow-hosted copy was found; this copy is labeled as third-party hosted. The text is EcoFlow's, but the page layout, page numbers and figures are Manuals+'s, so locators name the manual section. No revision or date is printed in the copy. Its Technical Specifications table is read. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • EcoFlow RIVER User Manual V1.1 (EN) (September 24, 2026 capture)Official · EcoFlow · Official user manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Connecting the Solar Panels; Specifications, Solar Charge Input

    Retrieved Sep 23, 2026

    EcoFlow RIVER user manual, preserved byte for byte, captured on September 24, 2026; the revision is whatever the URL served on that date and no later revision was checked. It was found through the EcoFlow US download center listing for the product (api-a.ecoflow.com download list behind ecoflow.com/us/support/download).

    Archived copies

    Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.72 MB

    Archived copy, unaltered, kept as a record of what EcoFlow published. Original address: https://websiteoss.ecoflow.com/cms/upload/2024/5/31/EcoFlow%20RIVER-User%20Manual-V1.0%EF%BC%88EN)_1655476774819_1717120878655.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    18

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 5fb9438bc2b51612fb01dcd9f3fa0c5cdee6be21387656262b9a15aea06b5e2a

    Open

Archived documents

EcoFlow RIVER User Manual V1.1 (EN) (September 24, 2026 capture)

Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.72 MB

Archived copy, unaltered, kept as a record of what EcoFlow published. Original address: https://websiteoss.ecoflow.com/cms/upload/2024/5/31/EcoFlow%20RIVER-User%20Manual-V1.0%EF%BC%88EN)_1655476774819_1717120878655.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
18

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5fb9438bc2b51612fb01dcd9f3fa0c5cdee6be21387656262b9a15aea06b5e2a

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
RIVER Plus

Manufacturer SKU RIVER-Plus-US · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: UL Standard · FCC +3
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 800 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [2]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. EcoFlow US store product data, EcoFlow RIVER Plus Portable Power Station (September 26, 2026 capture) (EcoFlow · manufacturer · observed Sep 26, 2026)
  2. EcoFlow RIVER Plus user manual, copy hosted by Manuals+ (September 26, 2026 capture) (EcoFlow · manufacturer document third party hosted · observed Sep 26, 2026)
  3. EcoFlow RIVER User Manual V1.1 (EN) (September 24, 2026 capture) (EcoFlow · manufacturer · observed Sep 23, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details