Printed as "Lithium-ion" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026. The specification table prints its labels and values in separate runs; the value is matched to its label by order and wording.
Printed as "15. Power Earth Screw" in EcoFlow's User Manual Contact us: www.ecoflow.com WARNING 1. Keep EcoFlow™ RIVER Max ("RIVER Max") and the accessories dry. DO NOT expose the product (PDF page 8). The manual applies to this model: User Manual V1.0 for EcoFlow RIVER Max.
Printed as "X-Stream Charge 500W Max" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026. The specification table prints its labels and values in separate runs; the value is matched to its label by order and wording.
W 184 × H 235 × L 289 mm / W 7.24 × H 9.25 × L 11.4 in converted
Printed as "11.4 x 7.3 x 9.3 in (28.9 x 18.4 x 23.5 cm)" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026.
Printed as "200W, 10-25Vdc, 12A Max" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026. The specification table prints its labels and values in separate runs; the value is matched to its label by order and wording.
Printed as "200W, 10-25Vdc, 12A Max" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026. The specification table prints its labels and values in separate runs; the value is matched to its label by order and wording.
Printed as "The RIVER Max can support a 10-25V DC input. When the input exceeds 25V, the RIVER Max overvoltage protection will be activated." in the solar panel section, and as "200W, 10-25Vdc, 12A Max" in the Specifications table. Capped at 12A and 200W. A generic input range, not labeled as an MPPT range or an open circuit voltage.
Where: User manual, Connecting the Solar Panels; Specifications, Solar Charge Input
Printed as "-4°F to 140°F (±5°F), -20°C to 60°C (±3°C) 32°F to 113°F (±5°F), 0 to 45°C (±3°C)" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026. The specification table prints its labels and values in separate runs; the value is matched to its label by order and wording. The second range is the charge temperature, printed with a tolerance of ±3°C.
Printed as "-4°F to 140°F (±5°F), -20°C to 60°C (±3°C) 32°F to 113°F (±5°F), 0 to 45°C (±3°C)" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026. The specification table prints its labels and values in separate runs; the value is matched to its label by order and wording. The first range is the discharge temperature, printed with a tolerance of ±3°C.
Printed as "UL Standard, CE, FCC, RoHS, RCM" in the EcoFlow RIVER Max user manual (V1.0, EN), Specifications, captured on September 26, 2026. Printed under "Testing and certification" as a marks list without standard numbers.
576 WhChemistry Lithium-ion · Cycle life 500 cycles
Rated AC output
600 WSurge AC output 1,200 W
Solar input limit
200 W
Solar input voltage
10-25 V
Weight
7.7 kg / 17 lbDimensions 184 W × 235 H × 289 L mm / 7.24 W × 9.25 H × 11.4 L in
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity500 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
EcoFlow's own manual, captured October 15, 2026 with the paced research fetcher (robots.txt read first). Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
The EcoFlow RIVER Max product page of EcoFlow's own United States store us.ecoflow.com, captured October 20, 2026 with the paced research fetcher to read the market it is sold for. Its region menu shows "United States (English / $ USD)" and its product data lists variant SKU EFRIVER600MAX-AM. Store statements, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
EcoFlow RIVER Max User Manual V1.1 (EN) (September 24, 2026 capture)
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
RIVER Max
US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Listing stated, none checked
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 500 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.