Printed as "NCM 500 cycles to 80%+ capacity" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. Printed as the Cell Chemistry value.
Printed as "1008Wh 50.4V" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. The printed 1008 Wh expressed in kWh.
Printed as "1600W total (surge 3100W)" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, AC output row). Surge duration not printed.
Printed as "10-65V 10A, 400W Max" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, Solar Charger row).
400 W
The value as the manual prints it, in W. Printed as "10-65V 10A, 400W Max" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, Solar Charger row).
Printed as "Pure Sine Wave, 1600W total (surge 3100W), 120V~ 60Hz" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026.
Printed as "X-Stream Fast Charge 1000W Max 100-120V~ 50Hz/60Hz" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, AC Charge row). DELTA 1000 table; the DELTA 1300 table on page 4 prints 1200W Max.
1,000 W
The value as the manual prints it, in W. Printed as "X-Stream Fast Charge 1000W Max 100-120V~ 50Hz/60Hz" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, AC Charge row). DELTA 1000 table; the DELTA 1300 table on page 4 prints 1200W Max.
Printed as "NCM 500 cycles to 80%+ capacity" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. Printed as the Cell Chemistry value.
Printed as "1008Wh 50.4V" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. The printed 1008 Wh expressed in kWh.
Printed as "1600W total (surge 3100W)" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, AC output row). Surge duration not printed.
Printed as "10-65V 10A, 400W Max" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, Solar Charger row).
400 W
The value as the manual prints it, in W. Printed as "10-65V 10A, 400W Max" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, Solar Charger row).
Printed as "Pure Sine Wave, 1600W total (surge 3100W), 120V~ 60Hz" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026.
Printed as "X-Stream Fast Charge 1000W Max 100-120V~ 50Hz/60Hz" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, AC Charge row). DELTA 1000 table; the DELTA 1300 table on page 4 prints 1200W Max.
1,000 W
The value as the manual prints it, in W. Printed as "X-Stream Fast Charge 1000W Max 100-120V~ 50Hz/60Hz" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 5, 1. Specifications, DELTA 1000 table, AC Charge row). DELTA 1000 table; the DELTA 1300 table on page 4 prints 1200W Max.
Printed as "automatically switch to battery-powered supply mode within 30ms" in the EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture) (PDF page 13, 3.7 Emergency Power Supply (EPS)). Printed as a maximum ("within"); the manual adds that it does not support 0ms switching.
Printed as "NCM 500 cycles to 80%+ capacity" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026.
Converted: 30.9 lb x 0.45359237 kg/lb, rounded to 0.01 kg
Printed as "Approximately 30.9lbs 15.7 x 8.3 x 10.6in" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. Printed as approximate, in pounds only.
Converted: 15.7 x 8.3 x 10.6 in x 25.4 mm/in, rounded to 0.1 mm
Printed as "Approximately 30.9lbs 15.7 x 8.3 x 10.6in" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. Printed in inches without axis labels; recorded in printed order.
Printed as "68°F to 86°F(20°C to 30°C) -4°F to 113°F (-20°C to 45°C) 32°F to 113°F(0°C to 45°C) -4°F to 113°F (-20°C to 45°C)" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. The table prints its labels and values in separate runs; the four ranges are matched to the Optimal Operating, Discharge, Charge and Storage labels by order.
Printed as "68°F to 86°F(20°C to 30°C) -4°F to 113°F (-20°C to 45°C) 32°F to 113°F(0°C to 45°C) -4°F to 113°F (-20°C to 45°C)" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. The table prints its labels and values in separate runs; the four ranges are matched to the Optimal Operating, Discharge, Charge and Storage labels by order.
Printed as "68°F to 86°F(20°C to 30°C) -4°F to 113°F (-20°C to 45°C) 32°F to 113°F(0°C to 45°C) -4°F to 113°F (-20°C to 45°C)" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. The table prints its labels and values in separate runs; the four ranges are matched to the Optimal Operating, Discharge, Charge and Storage labels by order.
ShopSolar's product data prints barcode 842783102157 for its variant "EcoFlow Delta 1000" (SKU EFDELTA1000-AM), the exact variant this record's ShopSolar offer links; the SKU equals the record's manufacturer SKU. A seller statement; package, bundle and regional variants carry their own codes, and no code is carried to another variant.
Printed as "X-Stream Fast Charge 1000W Max" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. Printed for X-Stream fast AC charging.
Printed as "Pure Sine Wave, 1600W total (surge 3100W), 120V~ 60Hz" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. AC (x6) total, pure sine wave.
Printed as "1008Wh 50.4V" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. Printed with the 50.4V battery voltage.
Printed as "Pure Sine Wave, 1600W total (surge 3100W), 120V~ 60Hz" in the EcoFlow DELTA user manual V1.1 (EN-US), Specifications, DELTA 1000, captured on September 26, 2026. Printed as surge; no duration is stated.
Published claims and calculations, not independent test results.
Documents
1 on file
PDF
EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture)OfficialEcoFlowOfficial user manual
Source details
Revision
Not stated
Revision date
Not stated
Location: 1. Specifications, Input Ports, Solar Charger (DELTA 1300 and DELTA 1000 tables); 3.5 Solar Charging
Retrieved
EcoFlow DELTA user manual, preserved byte for byte, captured on September 24, 2026; the revision is whatever the URL served on that date and no later revision was checked. It was found through the EcoFlow US download center listing for the product (api-a.ecoflow.com download list behind ecoflow.com/us/support/download). The manual prints separate tables for DELTA 1300 and DELTA 1000; both print the same solar charger figure.
Archived copies
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
EcoFlow DELTA User Manual V1.1 (EN-US) (September 24, 2026 capture)
Archived copy of a document published by EcoFlow. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Power stations · 120 V AC · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity500 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.