About brandBioenno Power, based in Santa Ana, California, sells LiFePO4 batteries, LiFePO4 battery chargers, solar charge controllers, foldable solar panels and power packs through its own online store.
SKU detail
locator: Store product data, product 4615827914826, variant "sku" field
conditions: Printed as "sku":"BPP-M500" for this product in Bioenno Power's store product data, captured October 22, 2026.
AC outlet (pure sine wave, 500W max); 4 DC barrel sockets 5.5 x 2.1 mm and a car socket (9-12.6VDC, 10A max); USB 5-9V/2A QuickCharge 3.0; USB-C 5-9V/2A QuickCharge 3.0; 2 USB 5V/3.1A
Printed as "DC Outputs 5.5 mm x 2.1 mm x 4 sockets., Car Socket, at 9VDC to 12.6VDC at 10 Amps max." and "USB Output 1 x USB 5V ~ 9V/2A QualComm QuickCharge 3.0 1 x Type-C 5V ~ 9V/2A QualComm QuickCharge 3.01 2 x USB 5V / 3.1 A"; the manual notes a DC barrel socket cannot carry more than 6 Amps.
Bioenno Power documents disagree on the cell chemistry. The BPP-M500 user manual (Rev 9/26/2023) prints "NCM type chemistry"; the store product page prints "Battery Type: NCA (Lithium-Ion)". The manual value is recorded first and the page value is kept beside it.
Printed as "NCM type chemistry" in the manual, which also says "Rechargeable Li-Ion battery".
Printed as "AC Output: Pure Sine Wave Inverter: 500 Watts Max. Do not exceed 500 Watts on the AC Output." in the manual; the store page prints "AC Output: Continuous: 500W".
Where: PDF page 3, How to Use step 12; store page Key features
Printed as "Capacity 520 Watt-Hours, (11.1V), NCM type chemistry" in the manual; the store page prints "Battery Capacity: 47Ah at 11.1V = 520 Watt-hours".
W 200 × H 176 × L 300 mm / W 7.87 × H 6.93 × L 11.8 in convertedCheck note
Bioenno Power documents disagree on the dimensions. The BPP-M500 user manual prints 300 x 200 x 176 mm; the store product page prints 306 mm x 200 mm x 176 mm. The manual value is recorded first and the page value is kept beside it.
Printed as "Dimensions 300 x 200 x 176 mm" in the manual.
Where: PDF page 5, Specifications
Sources
W 200 × H 176 × L 306 mm
Printed as "Dimensions: 12.04 in. x 7.9 in. x 6.9 in. (306 mm x 200 mm x 176 mm)".
Bioenno Power documents disagree on the operating temperature. The BPP-M500 user manual prints -10 to 40 deg C; the store product page prints 0°C to 40°C. The manual value is recorded first and the page value is kept beside it.
Printed as "Temperature of Operation: -10 deg C to 40 deg C (14 deg F to 104 deg F)".
Where: PDF page 5, Specifications
Sources
0 to 40 °C
Printed as "Operating Temperature: 32°F to 104°F (0°C to 40°C)".
6.5 kg / 14 lbDimensions 200 W × 176 H × 300 L mm / 7.87 W × 6.93 H × 11.8 L in
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
Power stations · Output unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a power station: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Bioenno Power's own user manual, linked from its store product page and served from the store's file host (cdn.shopify.com), captured on October 22, 2026 with the paced research fetcher. The file name carries the date 2023-09-26. Manufacturer statements, not independent tests.
Archived copies
Archived copy of a document published by Bioenno Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Bioenno Power's own US store product page (bioennopower.com), captured on October 22, 2026 with the paced research fetcher. Manufacturer statements, not independent tests; the page carries no revision date.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Bioenno Power BPP-M500 user manual (Rev 9/26/2023)
Archived copy of a document published by Bioenno Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
BPP-M500
Manufacturer SKU BPP-M500 · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 0
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 2743; UL 1973; CEC not applicable to portable power stations; UL 9540 not applicable to portable power stations.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: no
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not published. No lifetime-production bonus.