Printed as "43 (±2 )" in the NOCT (Nominal Operating Cell Temperature) row of the Temperature ratings table, whose unit sign after each number does not decode in the PDF's text layer, in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Printed as "2000V BIFACIAL DUAL GLASS MONOCRYSTALLINE MODULE" in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Printed as "N-type TOPCon Monocrystalline"; page 1 calls it an N-type TOPCon 2000V bifacial dual glass monocrystalline module with SMBB (super multi-busbar) technology, in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Printed as "TS4 Plus*", with the footnote "*Please refer to regional datasheet for specified connector." in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Printed as a framed module with 2.0 mm front and back glass (dual glass) in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Where: Page 2, Mechanical data, Front Glass, Back Glass and Frame
Trina's Vertex series user manual (UM-M-0002-G-EN, Ver. P, August 2026), which names NFG19RC.20, prints "Uplift load ≤ 2400 Pa" and "Downforce load ≤ 5400 Pa" for it with screws in the frame's mounting holes and rails parallel to the short side frame (holes 1400 mm apart, page 21) and with four clamps on the long side and rails perpendicular to the long side frame, A = (470 - 540) mm (page 24); it says its loads are test loads and that design loads are the test loads divided by a safety factor of 1.5 (page 18). Other mounting methods in the manual carry lower loads or none.
Where: Manual pages 18, 21 and 24 (6.2 Installation method)
W 1,142 × L 2,390 × D 30 mm / W 44.96 × L 94.09 × D 1.2 in converted
Printed as "2390×1142×30 mm (94.09×44.96×1.18 inches)" in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Trina's Vertex series user manual (UM-M-0002-G-EN, Ver. P, August 2026), which names NFG19RC.20, prints "Uplift load ≤ 2400 Pa" and "Downforce load ≤ 5400 Pa" for it with screws in the frame's mounting holes and rails parallel to the short side frame (holes 1400 mm apart, page 21) and with four clamps on the long side and rails perpendicular to the long side frame, A = (470 - 540) mm (page 24); it says its loads are test loads and that design loads are the test loads divided by a safety factor of 1.5 (page 18). Other mounting methods in the manual carry lower loads or none.
Where: Manual pages 18, 21 and 24 (6.2 Installation method)
Printed as "595" in the Peak Power Watts-PMAX (Wp) row, with a power tolerance of "0 ~ +5" W (Power Selection, footnoted "Power selection up to: +3%") and a measuring tolerance of ±3% in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Where: Page 2, Electrical data (STC), Peak Power Watts-PMAX row, 595 W column
Printed as "2000V DC (UL)" (no IEC line is printed), and page 1 prints "Maximum system voltage of 2000V", in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Where: Page 2, Maximum ratings, Maximum System Voltage
Printed as "-40~+85", followed by a unit sign the PDF's text layer does not decode, in the Operational Temperature row of the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Where: Page 2, Maximum ratings, Operational Temperature
Printed as "- 0.29% /", followed by a unit sign the PDF's text layer does not decode, under Temperature ratings in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8). Page 1 prints "Lower temperature coefficient (-0.29%/°C)".
Where: Page 2, Temperature ratings, Temperature Coefficient of PMAX
Printed as "0.04% /", followed by a unit sign the PDF's text layer does not decode, under Temperature ratings in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Where: Page 2, Temperature ratings, Temperature Coefficient of ISC
Printed as "- 0.24% /", followed by a unit sign the PDF's text layer does not decode, under Temperature ratings in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Where: Page 2, Temperature ratings, Temperature Coefficient of VOC
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Every scored input has a recorded source for this product.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed as "12-year Product Warranty", with "Please refer to product warranty for details", in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Power temperature coefficient-0.29 %/°C12.1 / 16.0
0.29 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "- 0.29% /", followed by a unit sign the PDF's text layer does not decode, under Temperature ratings in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8). Page 1 prints "Lower temperature coefficient (-0.29%/°C)".
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Retention
87.4 %
Printed as "87.4%" at year 30 on the guaranteed power chart, which starts at "99.0%", in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Printed as "12-year Product Warranty", with "Please refer to product warranty for details", in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Printed as "0.4% Annual Power Attenuation" in the Trina Solar Vertex N TSM-NFG19RC.20 600-620W North American preliminary datasheet (TSM_NA_EN_2025_PA8).
Location: Applicable module type list; pages 18, 20, 21, 23 and 24
Retrieved Oct 21, 2026
Trina Solar's installation manual for its Vertex series modules, which lists the NEG19RC.20, NEG21C.20, NED19RC.20, NFG19RC.20 and NEG9RH.25 module codes among the modules it covers, hosted on Trina's US site and fetched on October 22, 2026 (UTC). Its mechanical loads are test loads.
Archived copies
Archived copy of a document published by Trina Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Trina Solar's North American datasheet for the Vertex N TSM-NFG19RC.20 2000 V bifacial dual glass module, version TSM_NA_EN_2025_PA8, which carries a red "Preliminary" stamp on both pages; page 1 names the series 600 to 620 W and the electrical table prints 595 to 620 W. Hosted on Trina's US site and fetched on October 22, 2026 (UTC); it is the newest edition Trina hosts and its figures may change in a final sheet.
Archived copies
Archived copy of a document published by Trina Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Trina Solar Vertex N TSM-NFG19RC.20 2000V datasheet, North America, stamped "Preliminary" (TSM_NA_EN_2025_PA8)
Archived copy of a document published by Trina Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Trina Solar User Manual, Vertex Series Modules (UM-M-0002-G-EN, Ver. P, August 2026)
Archived copy of a document published by Trina Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.