Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "Anodized aluminum alloy". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Frame)
SunPro Power's SPDG (540/565W)-144M10 datasheet prints the SPDG540-144M10 at STC as "540 41.69 12.96 49.58 13.84" (Pmax, Vmp, Imp, Voc, Isc); the Maximum power current (Imp) figure reads 12.96. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SPDG540-144M10 row, Maximum power current (Imp)
SunPro Power's SPDG (540/565W)-144M10 datasheet prints the SPDG540-144M10 at STC as "540 41.69 12.96 49.58 13.84" (Pmax, Vmp, Imp, Voc, Isc); the Short circuit current (Isc) figure reads 13.84. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SPDG540-144M10 row, Short circuit current (Isc)
SunPro Power's SPDG (540/565W)-144M10 datasheet prints the SPDG540-144M10 at STC as "540 41.69 12.96 49.58 13.84" (Pmax, Vmp, Imp, Voc, Isc); the Maximum power voltage (Vmp) figure reads 41.69. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SPDG540-144M10 row, Maximum power voltage (Vmp)
SunPro Power's SPDG (540/565W)-144M10 datasheet prints the SPDG540-144M10 at STC as "540 41.69 12.96 49.58 13.84" (Pmax, Vmp, Imp, Voc, Isc); the Open circuit voltage (Voc) figure reads 49.58. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SPDG540-144M10 row, Open circuit voltage (Voc)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "ELECTRICAL CHARACTERISTICS WITH 15% REAR SIDE POWER GAIN". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, ELECTRICAL CHARACTERISTICS WITH 15% REAR SIDE POWER GAIN section (module is dual-glass bifacial)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "144cells ( Half-Cell ), Mono-Crystalline PERC, 182x91mm(7.17x3.58in)". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Cell)
On a grounding hole with a diameter of φ4 mm, use a separate grounding wire; M4*12mm bolts and M4 nuts, star washers and plain washers; ground fixation is 4N·m~8N·m; It is recommended to use the copper wire (4-14mm2 or AWG 6-12)
Printed as "On a grounding hole with a diameter of φ4 mm, use a separate grounding wire", "M4*12mm bolts and M4 nuts, star washers and plain washers", "ground fixation is 4N·m~8N·m" and "It is recommended to use the copper wire (4-14mm2 or AWG 6-12)" in the Grounding section of Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Bifacial Double Glass Installation Manual (no revision printed). The same section also allows grounding by unused mounting holes or other certified grounding devices (UL467) and recommends 10-12 AWG bare copper wire for the traditional method.
Where: PDF pages 62-63, section 5.5.2 (6) Grounding
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from the column headed SPDG540-144M10. Printed value: "31kg(68.34Ib)". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "144cells ( Half-Cell ), Mono-Crystalline PERC, 182x91mm(7.17x3.58in)". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Cell)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "MC4 compatible IP68". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Connector)
Printed beside the Front glass row label as "2.0mm ultra clear embossed semi-tempered coated glass" in SunPro Power P-type SPDGxxx-144M10 540-565W (35mm compatible) datasheet, captured on September 28, 2026.
Where: Page 2, Structural Characteristics table, Front glass row (confirmed by page render; the extracted text runs the row values together but keeps each value contiguous and unscrambled)
Printed as "Applied torque should refer to mechanical design standard according to the bolt customer is using, ex: M8 16-20N.m(140-180lbf.in)" in Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Bifacial Double Glass Installation Manual (no revision printed). Given as an example for an M8 clamp bolt; the manual says the applied torque should follow the mechanical design standard for the bolt used. Printed in N.m first, with 140-180 lbf.in beside it.
Where: PDF page 52, section 5.5.1, Mounting with Clamps, torque sentence
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "IP68". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Junction box)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "+5400Pa/-2400Pa". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Mechanical load capacity)
Printed beside the Back glass row label as "2.0mm white mesh semi-tempered glass" in SunPro Power P-type SPDGxxx-144M10 540-565W (35mm compatible) datasheet, captured on September 28, 2026.
Where: Page 2, Structural Characteristics table, Back glass row (confirmed by page render)
W 1,134 × H 2,278 × D 35 mm / W 44.65 × H 89.69 × D 1.4 in converted
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SPDG540-144M10. Printed value: "2278x1134x35mm". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Module size (L*W*H) 2278x1134x35mm(89.69X44.65X1.38in) Power tolerance 0~+5W"
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "+5400Pa/-2400Pa". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Mechanical load capacity)
SunPro Power's SPDG (540/565W)-144M10 datasheet prints the SPDG540-144M10 at STC as "540 41.69 12.96 49.58 13.84" (Pmax, Vmp, Imp, Voc, Isc); the Power (Pmax/W) figure reads 540. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SPDG540-144M10 row, Power (Pmax/W)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "30A". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Maximum rated fuse current)
PV modules can be installed through clamp method.; Use at minimum 4 clamps to attach modules to the mounting rails.; The clamp must overlap the module frame by at least 7mm but no more than 10mm.; A=1/4L±50mm;L=Module length; Front side: 3600Pa Back side: 1600Pa; S=100~240mm;; Lower; This installation mode is not recommended
Printed as "PV modules can be installed through clamp method." (PDF page 51, section 5.5.1) and "Use at minimum 4 clamps to attach modules to the mounting rails." (PDF page 52) in Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Bifacial Double Glass Installation Manual (no revision printed). The clamp table on PDF page 53, row "108/110/120/132/144 / 156pcs double-glass", gives "Front side: 3600Pa Back side: 1600Pa" with safety factor 1.5 for clamps at "A=1/4L±50mm;L=Module length" on rails perpendicular to the long side, and "Lower" for clamps at "S=100~240mm;" on rails perpendicular to the short side, of which it says "This installation mode is not recommended". Its note to the long-side drawing reads "This installation may cause the cell covered, so Zhejiang Sunpro doesnot recommend this installation for Framed Bifacial double-glass." The loads are described there as an empirical value of a standard module; section 5.2 calls 3600 (front)/1600 (back) the design pressure. The value lists the long-side clamp position and its load, then the short-side clamp position, its load entry and the table's remark, in the table's order.
Where: PDF pages 51-53, section 5.5.1 Mechanical Installation and Warning, Mounting with Clamps and clamp table
The minimum bending radius of the cables must be 43mm.
Printed as "The minimum bending radius of the cables must be 43mm." in Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Bifacial Double Glass Installation Manual (no revision printed), a statement for all its modules' PV cables.
SunPro Power's SPDG (540/565W)-144M10 datasheet prints "0~+5W 1500V 30A" (Power tolerance, Maximum system voltage, Maximum rated fuse current); the Maximum rated fuse current reads 30 A for the series, which includes the SPDG540-144M10. Revised on 17 October 2026: The fact rested only on an Internet Archive copy of SunPro's installation manual, which is no longer published (its URL now redirects to the home page); SunPro's own live datasheet prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet, Operating Parameters, Maximum rated fuse current
SunPro Power's SPDG (540/565W)-144M10 datasheet prints a maximum system voltage of "1500V" for the series, which includes the SPDG540-144M10. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Operating Parameters, Maximum system voltage
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from the column headed SPDG540-144M10. Printed value: "20.89%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "-40~+85℃". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Operating temperature range)
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SPDG540-144M10. Printed value: "(TK Pmax) -0.34% / ℃". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Connector MC4 compatible IP68 Temp. Coefficient of Pmax (TK Pmax) -0.34% / ℃"
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "0.048% / ℃". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, TEMPERATURE CHARACTERISTICS (Temp. Coefficient of Isc)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a table or row headed by model SPDG540-144M10. Printed: "-0.27% / ℃". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, TEMPERATURE CHARACTERISTICS (Temp. Coefficient of Voc)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from the column headed SPDG540-144M10. Printed value: "20.89%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Printed on the warranty panel of the SunPro Power SPDG (540/565W)-144M10 datasheet (www.sunpropower.us) as a 15 year "Quality Guarantee" and a 30 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SPDG (540/565W)-144M10 family. The datasheet does not print the warranty terms, exclusions or claim process, and adds "Extended warranty available upon request at additional cost".
This is the best documented for a solar panel, printed by the maker. 870 solar panels share this value.
Printed on the warranty panel of the SunPro Power SPDG (540/565W)-144M10 datasheet (www.sunpropower.us) as a 15 year "Quality Guarantee" and a 30 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SPDG (540/565W)-144M10 family. The yearly output steps are printed only as chart labels.
Power temperature coefficient-0.34 %/°C10.4 / 16.0
0.34 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPDGxxx-144M10-540-565W-35mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SPDG540-144M10. Printed value: "(TK Pmax) -0.34% / ℃". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
SPDG540-144M10
Limitations
Model SPDG540-144M10 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Zhejiang Sunpro Power Technology Co., Ltd., as "SPDG540-144M10", CEC listing date 2024-09-11. This is an equipment listing, not UL certification or complete-system approval.
Printed on the warranty panel of the SunPro Power SPDG (540/565W)-144M10 datasheet (www.sunpropower.us) as a 15 year "Quality Guarantee" and a 30 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SPDG (540/565W)-144M10 family. The datasheet does not print the warranty terms, exclusions or claim process, and adds "Extended warranty available upon request at additional cost".
Printed on the warranty panel of the SunPro Power SPDG (540/565W)-144M10 datasheet (www.sunpropower.us) as a 15 year "Quality Guarantee" and a 30 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SPDG (540/565W)-144M10 family. The yearly output steps are printed only as chart labels.
Zhejiang Sunpro Power Technology's own installation manual for its double glass solar modules ("BIFACIAL DOUBLE GLASS INSTALLATION MANUAL"), English and Chinese. It was obtained from the Internet Archive's Wayback Machine copy of Zhejiang Sunpro's own file at sunpropower.com (snapshot of March 23, 2025), because sunpropower.com now redirects to the SunPro Power US home page and the copy Zhejiang Sunpro posted in January 2026 could not be read; that later file is named for the same revision date as this copy's internal date (July 16, 2024), but its content was not compared. No revision is printed in the document. Its electrical rating table (section 3.6) has a row per power class for each series it names, and its installation sections apply to all the maker's double glass modules; it gives series-level installation instructions and tabulated ratings, and mechanical loads depend on the mounting method. Manufacturer instructions, not independent tests. It names, among others, the SPDGxxx-N108M10, SPDGxxx-144M10, SPDGxxx-N144M10 and SPDGxxx-N132R12 series and rows SPDG420-N96R12 to SPDG450-N96R12.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: P-type Solar Module products list
Retrieved Sep 24, 2026
SunPro Power North America product page on www.sunpropower.us listing the SPDGxxx-144M10 540-565W, SPxxx-108M10 395-420W series, each with one product image and a link to its datasheet, captured on September 25, 2026. It names series (for example SPDGxxx-N96R12), not individual wattage models, so each image shows the series rather than one wattage.
Archived copy of a document published by SunPro Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by SunPro Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SPDG540-144M10
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model SPDG540-144M10 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Zhejiang Sunpro Power Technology Co., Ltd., as "SPDG540-144M10", CEC listing date 2024-09-11. This is an equipment listing, not UL certification or complete-system approval.