Star Solar STAR-440W-M60H-M10
- Brand
- Star Solar
- Model
- STAR-440W-M60H-M10
- SKU / part number
- STAR-440W-M60H-M10[1]
- Category
- Solar panels

Electrical at STC
| Rated output (STC) | 440 W[1, 4] |
|---|---|
| Module efficiency | 20.31 %[2]Provisional |
| Voltage at max power (Vmp) | 34.5 V[2]Provisional |
| Current at max power (Imp) | 12.74 A[2]Provisional |
| Open-circuit voltage (Voc) | 41.2 V[1, 2, 4] |
| Short-circuit current (Isc) | 13.54 A[2, 4] |
| Power tolerance | ? |
Temperature and system limits
| Temperature coefficient, Pmax | -0.37 %/°C[2]Provisional |
|---|---|
| Temperature coefficient, Voc | ? |
| Temperature coefficient, Isc | ? |
| Maximum system voltage | 1,500 V[1, 4] |
| Maximum series fuse | 25 A[4]Needs confirmation |
| NOCT / NMOT | ? |
| Rated output at NMOT | ? |
| Operating temperature | ? |
Cells and construction
| Cell technology | Monocrystalline[1]Provisional |
|---|---|
| Cell count | 120 cells[4] |
| Bifacial | ? |
| Bifaciality | ? |
| Frame | ? |
| Front glass | 3.2mm high transmission, antireflection coating[3] |
| Back cover | ? |
| Panel format | ? |
Mechanical and connections
| Dimensions | 35 D × 1,134 W × 1,910 L mm[1, 4] |
|---|---|
| Weight | ? |
| Connectors | ? |
| Cable length | ? |
| Junction box rating | ? |
| Mounting | ? |
| Design load, front | ? |
| Design load, rear | ? |
Installation (from the manual)
Torque
| Clamp or bolt torque | 16 to 20 N·m(141.61 to 177.01 in-lb*)[4] |
|---|
Clearances and orientation
| Mounting methods and clamp zones | Screw installation: 8 mounting holes, M8 corrosion-proof screws with spring washers and flat washers in eight symmetrical locations (Table 1: 5400Pa Load Tested); Clamp installation on the long sides, Table 3 Type 2 (STAR-440W-M60H-M10, a 1910 mm, b 1134 mm, clamp length ≥50 mm): mounting area A 180 mm to B 480 mm, 3600 Pa; A 0 mm to B 480 mm, 1600 Pa; Clamps: a minimum of four clamps, on the long or the short side within the constraints of drawing 2[4] |
|---|
Grounding
| Grounding | Where common grounding hardware (nuts, bolts, star washers, spilt-ring lock washers, flat washers and the like) is used to attach a listed grounding/bonding device, the attachment must be made in conformance with the grounding device manufacturer’s instructions.; If grounding is required, the grounding wire must be properly fastened to the module frame to assure adequate electrical connection.[4] |
|---|
Not in the manual: Conductors
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.