Charged Reviews · Quick reference
SEG Solar SEG-590-BTA-BG
- Brand
- SEG Solar
- Model
- SEG-590-BTA-BG
- SKU / part number
- SEG-590-BTA-BG T1 Provisional [1]
- Category
- Solar panels
chargedreviews.com/panels/seg-solar-seg-590-bta-bg-t1
Electrical at STC
- Module efficiency
- ?
- Power tolerance
- ?
Temperature and system limits
- Temperature coefficient, Pmax
- ?
- Temperature coefficient, Voc
- -0.25 %/°C [2]
- Temperature coefficient, Isc
- ?
- Maximum series fuse
- ?
- NOCT / NMOT
- ?
- Rated output at NMOT
- ?
- Operating temperature
- ?
Cells and construction
- Cell technology
- ?
- Cell count
- ?
- Bifaciality
- ?
- Frame
- ?
- Front glass
- ?
- Back cover
- ?
- Panel format
- ?
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 16 to 20 N·m [4]
Clearances and orientation
- Mounting methods and clamp zones
- Screw installation (Table 2): Four outer mounting holes, +5400/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail cross the long side, L=A/4±50mm: +5400/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail parallel the long side, L=A/4±50mm: +2400/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail cross the short side, W=B/4±50mm: +3600/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail parallel the short side, W=B/4±50mm: not given (/); Tracker installation (Table 4): Nextracker 400mm hole distance +2400/-2400 790mm hole distance +3150/-2550; Other installation, Method A six clamps (Table 5): clamp ≥80mm, A/4±50, +5400/-3600 Pa; Method B four screws plus four clamps (Table 6): +5400/-3600 Pa [4]
Grounding
- Grounding
- A bonding or toothed washer is required to make proper and reliable electrical grounding connection with the anodized aluminum frame.; Consider using a lay-in lug, rated for outdoor use, if the module grounding conductor is to be larger than 10 AWG. [4]
Not in the manual: Conductors