Runergy HY-DH132N10-Plus-730

Brand
Runergy
Model
HY-DH132N10-Plus-730
SKU / part number
?
Category
Solar panels
chargedreviews.com/panels/runergy-hy-dh132n10-plus-730

Electrical at STC

Rated output (STC)730 W[1]
Module efficiency23.5 %[1]
Voltage at max power (Vmp)41.67 V[1]
Current at max power (Imp)17.52 A[1]
Open-circuit voltage (Voc)49.77 V[1]
Short-circuit current (Isc)18.59 A[1]
Power tolerance?

Temperature and system limits

Temperature coefficient, Pmax-0.29 %/°C[1]
Temperature coefficient, Voc-0.25 %/°C[1]
Temperature coefficient, Isc0.05 %/°C[1]
Maximum system voltage1,500 V[1]
Maximum series fuse?
NOCT / NMOT45 °C[1]
Rated output at NMOT?
Operating temperature-40 to 85 °C[1]

Cells and construction

Cell technologyMono N-Type 210mm[1]
Cell count132 cells[1]
BifacialYes[1]
Bifaciality?
FrameAluminum, silve anodized[1]
Front glass2.0mmAR coated heat strengthened glass[1]
Back cover2.0mm heat strengthened glass[1]
Panel formatrigid[1]

Mechanical and connections

Dimensions35 D × 1,303 W × 2,384 L mm[1]
Weight38.5 kg / 84.88 lb[1]
ConnectorsRY01 or similar[1]
Cable length?
Junction box rating?
Mounting?
Design load, front?
Design load, rear?

Installation (from the manual)

Not documented in the manual

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Runergy HY-DH132N10-Plus-730 · HY-DH132N10-Plus-730

Warranty

Product warranty12 years[1]
Power warranty term30 years[1]
First-year degradation1 %[1]
Minimum output in year 1, as printed?
Annual degradation after year one0.4 %[1]
Warranted final output87.4 %[1]
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730ClaimedListed when checked[1]
UL 1703?
IEC 61215ClaimedListed when checked[1]
IEC 61730ClaimedListed when checked[1]
IEC 62804?
CEC listing?
IEC 61701ClaimedListed when checked[1]
IEC 62716ClaimedListed when checked[1]
IEC 60068ClaimedListed when checked[1]

Documents and sources

  1. HY-DH132N10 Plus 700-730W bifacial datasheet, HY-DH132N10-Plus-Global-Ver25Q4Official datasheet · Revision HY-DH132N10-Plus-Global-Ver25Q4 · Revised Not stated · Checked Oct 30, 2026https://www.runergy.com/wp-content/uploads/download/25Q4/Global%20N10%20H10%2025Q4/HY-DH132N10-Plus-Global-Ver25Q4(700-730W).pdf