Runergy HY-DH108N8B-425 (monofacial edition)

By RunergySKU not documented

No owner reviews yet · Write the first

Key specs

Units
Rated output (STC)
425 W
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Maximum Power at STC (Pmax/W) row, 425 W column

Documented

Module efficiency
21.8 %
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Module Efficiency row, 425 W column

Documented

Voltage at max power (Vmp)
32.67 V
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Voltage (Vmp/V) row, 425 W column

Documented

Current at max power (Imp)
13.01 A
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Current (Imp/A) row, 425 W column

Documented

Open-circuit voltage (Voc)
38.59 V
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Open Circuit Voltage (Voc/V) row, 425 W column

Documented

Short-circuit current (Isc)
13.64 A
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Short Circuit Current (Isc/A) row, 425 W column

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Printed as "-0.29%/°C" in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Temperature characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Operating parameters, Max. System Voltage

Documented

All specs27
Rated output (STC)
425 W
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Maximum Power at STC (Pmax/W) row, 425 W column

Documented

Module efficiency
21.8 %
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Module Efficiency row, 425 W column

Documented

Voltage at max power (Vmp)
32.67 V
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Voltage (Vmp/V) row, 425 W column

Documented

Current at max power (Imp)
13.01 A
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Optimum Operating Current (Imp/A) row, 425 W column

Documented

Open-circuit voltage (Voc)
38.59 V
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Open Circuit Voltage (Voc/V) row, 425 W column

Documented

Short-circuit current (Isc)
13.64 A
Official datasheet
Sources

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Electrical characteristics (STC), Short Circuit Current (Isc/A) row, 425 W column

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Printed as "-0.29%/°C" in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Temperature characteristics, Temperature Coefficient of Pmax

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Printed as "DC 1500V(IEC/UL)" in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 2, Operating parameters, Max. System Voltage

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1OfficialRunergyOfficial datasheet
    Certificate & compliance claims (6)
    IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
    IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
    UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
    IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
    IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
    IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
    Source details
    Revision
    HY-DH108N8B-Monofacial-Global-Ver25Q1
    Revision date
    Not stated

    Archived copy captured on 2026-10-30.

    Location: Pages 1 and 2

    Retrieved

    Runergy's two-page global datasheet for the HY-DH108N8B N-type monofacial dual glass module, 425 to 445 W (footer HY-DH108N8B-Monofacial-Global-Ver25Q1, file name Ver25Q3, copyright 2025), on Runergy's own file host (runergy.com) and linked from Runergy's download page, captured October 30, 2026 (UTC). Page 1 prints "HY-DH108N8B" with "Monofacial & Dual Glass" and a "Monofacial" mark, and page 2 heads the tables "HY-DH108N8B 425-445". It prints the same code as Runergy's HY-DH108N8B bifacial sheets. Electrical figures are read from each power class column of Electrical Characteristics - STC, checked against the rendered page 2. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 1.09 MB

    Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/N8-Series-(183-cell)/HY-DH108N8B-Global-Ver25Q3(Monofacial%20425-445W).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Jul 23, 2025
    Embedded modification date
    Jul 23, 2025

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: ab707766bd164c77630da22a522a8865c3f6b38cb883ca77eb07c2133dbb840e

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1

Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 1.09 MB

Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/N8-Series-(183-cell)/HY-DH108N8B-Global-Ver25Q3(Monofacial%20425-445W).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Jul 23, 2025
Embedded modification date
Jul 23, 2025

Embedded dates are file metadata, not independent proof of publication.

SHA-256: ab707766bd164c77630da22a522a8865c3f6b38cb883ca77eb07c2133dbb840e

Submit a document

Warranty

Warranted final output
87.4 %
Official datasheet
Sources

The warranty chart prints 87.4% at year 30 (and 89.4% at year 25) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 1, Product performance warranty chart

Documented

Product warranty
25 years
Official datasheet
Sources

Printed as "25-year product warranty" on page 1 and "Product Workmanship Warranty 25 Years" on page 2 of the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 1, Product performance warranty; page 2, Warranty

Documented

Annual degradation after year one
0.4 %
Official datasheet
Sources

Printed as "1st year degradation <1%, annual degradation <0.4%" on page 1 of the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1) (page 2: "Annual Power Degradation 0.4%"); an upper bound.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 1, Product performance warranty; page 2, Warranty

Documented

First-year degradation
1 %
Official datasheet
Sources

Printed as "1st year degradation <1%, annual degradation <0.4%" on page 1 of the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1) (page 2: "First Year Degradation 1%"); an upper bound.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 1, Product performance warranty; page 2, Warranty

Documented

Power warranty
30 years
Official datasheet
Sources

Printed as "30-year linear power warranty" on page 1 and "Linear Power Output Warranty 30 Years" on page 2 of the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Location: Page 1, Product performance warranty; page 2, Warranty

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

88/100100% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Every scored input has a recorded source for this product.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency21.8 %22.2 / 26.0

21.8 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the 425 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1); in the text layer the column prints "425 32.67 13.01 38.59 13.64 21.8%" in the order maximum power, optimum operating voltage, optimum operating current, open circuit voltage, short circuit current, module efficiency, confirmed on the rendered page 2. Front side only (a monofacial module); NMOT figures are not recorded here.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
Product warranty25 years17.5 / 21.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed as "25-year product warranty" on page 1 and "Product Workmanship Warranty 25 Years" on page 2 of the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
Power warranty30 years16.0 / 16.0

This is the best documented for a solar panel, printed by the maker. 827 solar panels share this value.

Printed as "30-year linear power warranty" on page 1 and "Linear Power Output Warranty 30 Years" on page 2 of the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1).

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
First-year degradation1 %16.0 / 16.0

This is the lowest documented for a solar panel, printed by the maker. 368 solar panels share this value.

Printed as "1st year degradation <1%, annual degradation <0.4%" on page 1 of the Runergy HY-DH108N8B 425-445W monofacial datasheet (HY-DH108N8B-Monofacial-Global-Ver25Q1) (page 2: "First Year Degradation 1%"); an upper bound.

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

6 on file12 claims on file · issuer check pending
IEC 61215Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH108N8B 425-445

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH108N8B 425-445

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
UL 61730Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH108N8B 425-445

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 61701Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH108N8B 425-445

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 62716Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH108N8B 425-445

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 60068Product / system scope unresolvedClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Models: HY-DH108N8B 425-445

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
Datasheet & manual claims6
IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document
IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

Runergy's HY-DH108N8B-Monofacial-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8B-425 in its monofacial edition; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

Manufacturer document

Official datasheet: HY-DH108N8B 425-445W monofacial datasheet, HY-DH108N8B-Monofacial-Global-Ver25Q1 Rev HY-DH108N8B-Monofacial-Global-Ver25Q1 · Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HY-DH108N8B-425

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.