Charged ReviewsSaved 0Compare 0Login
Solar panelNo photo yet
RunergyNo reviews of Runergy yet

Runergy HY-DH108N8-Trans-445

Key specs

BrandRunergy
ModelHY-DH108N8-Trans-445
Rated power445 W
Cell typeMono N-Type 182mm
Module efficiency22.8 %
Open-circuit voltage39.35 V
Short-circuit current13.96 A
DimensionsW 1,134 × L 1,722 × D 30 mm / W 44.65 × L 67.8 × D 1.2 in converted
Weight24.2 kg / 53.4 lb converted
Product warranty25 years
Power warranty30 years

All specifications

Show all 32 specifications

Identity

BrandRunergy · Website
ModelHY-DH108N8-Trans-445
RegionUnknown
Manufacturer SKUUnknown
About brandJiangsu Runergy New Energy Technology Co., Ltd. makes silicon material, solar cells and solar modules, including its N-Type series of double glass modules such as the all-black HY-DH108N8B for residential and commercial roofs. Some sellers list its modules under the name Hyperion.
SKU detail
Runergy's datasheet prints the series name HY-DH108N8 and the power class 445 (the datasheet's range is printed as "HY-DH108N8 425-445"), and no separate part number.
FieldValueConditionsSource
FrameBlack/ Silver anodized aluminum
Printed as "Black/ Silver anodized aluminum" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the datasheet does not say which frame color a given module has.
Where: Page 2, Mechanical parameters, Frame
[1]
Current at max power13.33 A
Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the text layer runs this column together with its neighbor, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.
Where: Page 2, Electrical characteristics (STC), Optimum Operating Current (Imp/A) row, 445 W column
[1]
Short-circuit current13.96 A
Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the text layer runs this column together with its neighbor, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.
Where: Page 2, Electrical characteristics (STC), Short Circuit Current (Isc/A) row, 445 W column
[1]
Voltage at max power33.39 V
Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the text layer runs this column together with its neighbor, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.
Where: Page 2, Electrical characteristics (STC), Optimum Operating Voltage (Vmp/V) row, 445 W column
[1]
Open-circuit voltage39.35 V
Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the text layer runs this column together with its neighbor, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.
Where: Page 2, Electrical characteristics (STC), Open Circuit Voltage (Voc/V) row, 445 W column
[1]
Nmot42 °C / 108 °F converted
Printed as "42 ± 2 °C" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the nominal cell operating temperature is printed as "45 ± 2 °C".
Where: Page 2, Temperature characteristics, Nominal Module Operating Temperature
[1]
Noct45 °C / 113 °F converted
Printed as "Nominal Cell Operating Temperature 45 ± 2 °C" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1), the line after "Nominal Module Operating Temperature 42 ± 2 °C" (recorded as the NMOT); the ±2 °C tolerance is noted here.
Where: Page 2, Temperature characteristics, Nominal Cell Operating Temperature
[1]
Bifacialyes
Printed as "N-Type Bifacial & Dual Glass" on page 1 and "Bifaciality 80%±5%" on page 2 of the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 1 heading; page 2, Operating parameters, Bifaciality
[1]
Cell typeMono N-Type 182mm
Printed as "Mono N-Type 182mm" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Mechanical parameters, Solar Cell
[1]
Weight24.2 kg / 53.4 lb converted
Printed as "24.2kg (53.35Ibs)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Mechanical parameters, Weight
[1]
Cell count108 cells
Printed as "108 (6 × 18)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Mechanical parameters, No. of Cells
[1]
ConnectorsEVO2 or similar
Printed as "EVO2 or similar" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); output cable printed as "4mm² (IEC), 12 AWG (UL) ±1200mm (47.24in.) or customized".
Where: Page 2, Mechanical parameters, Connector
[1]
Front glass2.0mm AR coated heat-strengthened glass
Printed as "2.0mm AR coated heat-strengthened glass" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Mechanical parameters, Front Cover
[1]
Junction boxIP68 rated (3 bypass diodes)
Printed as "IP68 rated (3 bypass diodes)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Mechanical parameters, Junction Box
[1]
Panel formatrigid
A framed dual glass module, as printed in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Mechanical parameters, Front Cover, Back Cover and Frame
[1]
Rear load pa2,400 Pa
Printed as "2400Pa (50lb/ft²)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Operating parameters, Backside Max. Loading
[1]
Rear surface2.0mm heat-strengthened glass
Printed as "2.0mm heat-strengthened glass" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Mechanical parameters, Back Cover
[1]
DimensionsW 1,134 × L 1,722 × D 30 mm / W 44.65 × L 67.8 × D 1.2 in converted
Printed as "1722 × 1134 × 30mm (67.80 x 44.65 x 1.18in)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1), in the order printed.
Where: Page 2, Mechanical parameters, Dimensions
[1]
Front load pa5,400 Pa
Printed as "5400Pa (112lb/ft²)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Operating parameters, Frontside Max. Loading
[1]
Rated power445 W
Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the text layer runs this column together with its neighbor, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here. The power tolerance is printed as 0 ~ +5 W.
Where: Page 2, Electrical characteristics (STC), Maximum Power at STC (Pmax/W) row, 445 W column
[1]
Series fuse30 A
Printed as "30A" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Operating parameters, Max. Fuse Rating
[1]
Max system voltage1,500 V
Printed as "DC 1500V(IEC/UL)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Operating parameters, Max. System Voltage
[1]
Module efficiency22.8 %
Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the text layer runs this column together with its neighbor, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.
Where: Page 2, Electrical characteristics (STC), Module Efficiency row, 445 W column
[1]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "-40°C ~ +85°C (-40℉ ~ +185℉)" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Operating parameters, Operating Temperature
[1]
Temperature coefficient-0.29 %/°C
Printed as "-0.29%/°C" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Temperature characteristics, Temperature Coefficient of Pmax
[1]
Isc temperature coefficient0.045 %/°C
Printed as "0.045%/ °C" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Temperature characteristics, Temperature Coefficient of Isc
[1]
Voc temperature coefficient-0.25 %/°C
Printed as "-0.25%/°C" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 2, Temperature characteristics, Temperature Coefficient of Voc
[1]

Owner reviews

No reviews. Be the first to review this product:
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Evidence score

89/100100% documented
Module efficiency22.8 %23.2 / 26.0

22.8 of 25.5 %, the best documented for a solar panel (printed by the manufacturer): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the 445 W column of Electrical Characteristics - STC (irradiance 1000 W/m², cell temperature 25 °C, AM-1.5; test uncertainty for Pmax ±3%) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); the text layer runs this column together with its neighbor, so the column was read on the rendered page 2 and its figures matched in the text layer rows. Front side only; NMOT, BNPI and rear-side gain figures are not recorded here.

[1]

Product warranty25 years17.5 / 21.0

25 of 30 years, the best documented for a solar panel (printed by the manufacturer): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed as "25-year product warranty" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).

[1]

Power warranty30 years16.0 / 16.0

This is the best documented for a solar panel, printed by the manufacturer. 870 solar panels share this value.

Printed as "30-year linear power warranty" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).

[1]

Power temperature coefficient-0.29 %/°C12.1 / 16.0

0.29 against 0.22 %/°C, the lowest documented for a solar panel (printed by the manufacturer): Jackery SolarSaga 100 Air

Printed as "-0.29%/°C" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).

[1]

First-year degradation1 %16.0 / 16.0

This is the lowest documented for a solar panel, printed by the manufacturer. 420 solar panels share this value.

Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); an upper bound.

[1]

Weight / watt24.2 kg / 445 W4.0 / 5.0

0.05438 against 0.04308 kg per W, the lowest documented for a rigid solar panel (calculated from maker figures): EcoFlow 130W RVMax Rigid Solar Panel

24.2 kg / 445 W. Lighter modules per watt carry less roof load.

[1]

How it works

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

Methodology

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
IEC 60068manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
HY-DH108N8 425-445
Limitations
Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61215manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
HY-DH108N8 425-445
Limitations
Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61701manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
HY-DH108N8 425-445
Limitations
Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61730manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
HY-DH108N8 425-445
Limitations
Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62716manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
HY-DH108N8 425-445
Limitations
Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 61730manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
HY-DH108N8 425-445
Limitations
Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Retention87.4 %
The warranty chart prints 87.4% at year 30 (and 89.4% at year 25) in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 1, Product performance warranty chart
[1]
Warranty term25 years
Printed as "25-year product warranty" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 1, Product performance warranty
[1]
Annual degradation0.4 %
Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); an upper bound.
Where: Page 1, Product performance warranty
[1]
Degradation year one1 %
Printed as "1st year degradation <1%, annual degradation <0.4%" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1); an upper bound.
Where: Page 1, Product performance warranty
[1]
Performance warranty30 years
Printed as "30-year linear power warranty" in the Runergy HY-DH108N8 Transparent 425-445W datasheet (HY-DH108N8-Trans-Global-Ver25Q1).
Where: Page 1, Product performance warranty
[1]

Documents

  • Datasheets

  • HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1Official · Runergy · Official datasheet · PDF
    Certificate & compliance claims (6)
    IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1
    IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1
    UL 61730Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1
    IEC 61701Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1
    IEC 62716Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1
    IEC 60068Manufacturer claim · unresolved document setClaimedListed when checked

    Runergy's HY-DH108N8-Trans-Global-Ver25Q1 datasheet prints "IEC61215 / IEC61730 / UL61730 / IEC61701 / IEC62716 / IEC60068 / ISO9001 / ISO14001 / ISO45001" on page 1 for the series, which includes HY-DH108N8-Trans-445; the ISO management system standards are not recorded as product certifications. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1
    Source details
    Revision
    HY-DH108N8-Trans-Global-Ver25Q1
    Revision date
    Not stated

    Archived copy captured on 2026-10-30.

    Location: Pages 1 and 2

    Retrieved Oct 29, 2026

    Runergy's two-page global datasheet for the HY-DH108N8 Transparent N-type bifacial dual glass module, 425 to 445 W (footer HY-DH108N8-Trans-Global-Ver25Q1, file name Ver25Q3, copyright 2025), on Runergy's own file host (runergy.com) and linked from Runergy's download page, captured October 30, 2026 (UTC). Page 1 prints "HY-DH108N8" with a "Transparent" mark and page 2 heads the tables "HY-DH108N8 425-445"; the Trans name is printed in the version line. The text layer runs the 425/430 W and 440/445 W columns together, so each power class column was read on the rendered page 2. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backupRevision not recorded · 1.20 MB

    Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/N8-Series-(183-cell)/HY-DH108N8-Trans-Global-Ver25Q3(425-445W)%20.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 3f01d69e3dad7daf86058724b01f0cd81cc54e03f6b4b5afe024440c9138fe61

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1

Archived copy of a document published by Runergy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backupRevision not recorded · 1.20 MB

Archived copy, unaltered, kept as a record of what Runergy published. Original address: https://www.runergy.com/wp-content/uploads/download/N8-Series-(183-cell)/HY-DH108N8-Trans-Global-Ver25Q3(425-445W)%20.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3f01d69e3dad7daf86058724b01f0cd81cc54e03f6b4b5afe024440c9138fe61

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HY-DH108N8-Trans-445

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 100
basis: Unknown
missing: None listed
criteria:
key: efficiency
label: Module efficiency
value: 22.8
unit: Unknown
shown: 22.8 %
shown detail: Unknown
state: documented
points: 23.2
ceiling: 26
weight: 26
share: 89.4
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: warranty
label: Product warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 17.5
ceiling: 21
weight: 21
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: performanceWarranty
label: Power warranty
value: 30
unit: Unknown
shown: 30 years
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: powerTemperature
label: Power temperature coefficient
value: 0.29
unit: Unknown
shown: -0.29 %/°C
shown detail: Unknown
state: documented
points: 12.1
ceiling: 16
weight: 16
share: 75.9
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: degradation
label: First-year degradation
value: 1
unit: Unknown
shown: 1 %
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: weightPerWatt
label: Weight / watt
value: 0.0544
unit: Unknown
shown: 24.2 kg / 445 W
shown detail: Unknown
state: documented
points: 4
ceiling: 5
weight: 5
share: 79.2
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 24.2 kg / 445 W. Lighter modules per watt carry less roof load.
display note: Unknown
Sources: [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. HY-DH108N8 Transparent 425-445W bifacial datasheet, HY-DH108N8-Trans-Global-Ver25Q1 (Runergy · manufacturer · observed Oct 29, 2026)

Sign in to report an error on this page

Similar products

All solar panels

Other solar panels a listed seller carries; most listed sellers pay us a commission.