conditions: Renogy prints no single-panel SKU; its US store sells the panel only in packs, with the pack SKUs RSP400DCT-108x2-US, RSP400DCT-108x4-US, RSP400DCT-108x6-US and RSP400DCT-108x10-US.
Printed as "Optimum Operating Current (Imp) 11.76A" in the RSP400DCT-108x2 column (read from the rendered table), under Standard Test Conditions (STC): 1,000 W/m2, 25 °C, AM1.5.
Printed as "Short-Circuit Current (Isc) 13.06A" in the RSP400DCT-108x2 column (read from the rendered table), under Standard Test Conditions (STC): 1,000 W/m2, 25 °C, AM1.5.
Printed as "Optimum Operating Voltage (Vmp) 34.0V" in the RSP400DCT-108x2 column (read from the rendered table), under Standard Test Conditions (STC): 1,000 W/m2, 25 °C, AM1.5.
Printed as "Open-Circuit Voltage (Voc) 39.42V" in the RSP400DCT-108x2 column (read from the rendered table), under Standard Test Conditions (STC): 1,000 W/m2, 25 °C, AM1.5.
Printed as "Maximum Power at STC 400W" in the RSP400DCT-108x2 column (read from the rendered table), under Standard Test Conditions (STC): 1,000 W/m2, 25 °C, AM1.5.
Printed as "Module Efficiency 21.5%" in the RSP400DCT-108x2 column (read from the rendered table), under Standard Test Conditions (STC): 1,000 W/m2, 25 °C, AM1.5.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed as "Module Efficiency 21.5%" in the RSP400DCT-108x2 column (read from the rendered table), under Standard Test Conditions (STC): 1,000 W/m2, 25 °C, AM1.5.
Renogy's two-page datasheet for its 320 W and 400 W N-type bifacial panels sold in packs of two, linked from the 400 W panel's US store page and captured on October 21, 2026; it prints no version or date. The Technical Specifications table on page 2 is cited; its text layer separates labels from values, so it was read from the rendered page, where the RSP400DCT-108x2 is the second column. Manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Store country and currency; product title; specification text
Retrieved Oct 21, 2026
Renogy's own US store page (www.renogy.com), captured on October 21, 2026 with the paced research fetcher; the store reports country US and prices in US dollars. Manufacturer claims, not independent tests; the page carries no revision date.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Renogy 320W/400W N-Type Bifacial Solar Panel (2-Pack) Datasheet, RSP320DT-BKx2-G2/RSP400DCT-108x2
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].